文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

入院前空气污染暴露延长重症监护患者机械通气时间

Pre-admission air pollution exposure prolongs the duration of ventilation in intensive care patients.
PubMed 文献 · Intensive Care Med · 2020-03-17
一句话结论ICU入院前10天内短期环境空气污染暴露与机械通气时间延长相关,黑碳每增加1.2 µg/m³对应通气时间累积增加12.4%。

该研究分析了比利时安特卫普大学医院ICU收治的2003例患者,均于入ICU时或入ICU后48小时内接受机械通气且通气至少48小时。利用高分辨率时空模型对每例患者家庭住址入院前10天的PM2.5、PM10、NO2和黑碳暴露进行建模,采用分布滞后模型结合负二项回归评估空气污染暴露与机械通气时间的关联。控制预设混杂因素后,入院前10天黑碳暴露每增加1.2 µg/m³(IQR),机械通气时间累积增加12.4%(95%CI 4.7-20.7);PM2.5、PM10和NO2也观察到显著关联,累积估计值为7.8%至8.0%。作者认为,ICU入院前短期环境空气污染暴露是机械通气时间延长的一个未被认识的环境风险因素。

要点

  • 入院前10天黑碳暴露每增加1.2 µg/m³(IQR),机械通气时间累积增加12.4%(95%CI 4.7-20.7)。
  • PM2.5、PM10和NO2也显示与机械通气时间延长显著相关,累积估计值为7.8%至8.0%。
  • 研究对象为入ICU时或入ICU后48小时内开始机械通气且通气至少48小时的2003例患者。
  • 空气污染暴露按患者家庭住址用高分辨率时空模型建模,覆盖入院前10天。
  • 作者认为ICU入院前短期环境空气污染暴露是机械通气时间延长的未被认识的环境风险因素。

适用人群与场景

  • 2003例入住安特卫普大学医院(比利时法兰德斯)ICU的患者,于入ICU时或入ICU后48小时内接受机械通气,且通气持续时间至少48小时。

研究设计与关键结果

  • 研究类型为对2003例患者病历资料的分析,采用分布滞后模型结合负二项回归评估入院前10天空气污染暴露与机械通气时间的关联。
  • 控制预设混杂因素后,入院前10天黑碳暴露每增加1.2 µg/m³(IQR),机械通气时间累积增加12.4%(95%CI 4.7-20.7)。
  • PM2.5、PM10和NO2与机械通气时间延长也呈显著关联,累积估计值为7.8%至8.0%。

证据类型、等级与局限

  • 证据类型:基于病历资料的分析研究。

对床旁实践的改变

  • 作者认为,ICU入院前短期环境空气污染暴露是机械通气时间延长的一个未被认识的环境风险因素。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

PURPOSE: Air pollutant exposure constitutes a serious risk factor for the emergence or aggravation of (existing) pulmonary disease. The impact of pre-intensive care ambient air pollutant exposure on the duration of artificial ventilation was, however, not yet established.

METHODS: The medical records of 2003 patients, admitted to the intensive care unit (ICU) of the Antwerp University Hospital (Flanders, Belgium), who were artificially ventilated on ICU admission or within 48 h after admission, for the duration of at least 48 h, were analyzed. For each patient's home address, daily air pollutant exposure [particulate matter with an aerodynamic diameter ≤ 2.5 µm (PM2.5) and ≤ 10 µm (PM10), nitrogen dioxide (NO2) and black carbon (BC)] up to 10 days prior to hospital admission was modeled using a high-resolution spatial-temporal model. The association between duration of artificial ventilation and air pollution exposure during the last 10 days before ICU admission was assessed using distributed lag models with a negative binomial regression fit.

RESULTS: Controlling for pre-specified confounders, an IQR increment in BC (1.2 µg/m3) up to 10 days before admission was associated with an estimated cumulative increase of 12.4% in ventilation duration (95% CI 4.7-20.7). Significant associations were also observed for PM2.5, PM10 and NO2, with cumulative estimates ranging from 7.8 to 8.0%.

CONCLUSION: Short-term ambient air pollution exposure prior to ICU admission represents an unrecognized environmental risk factor for the duration of artificial ventilation in the ICU.

来源:Intensive Care Med,查看原文。版权归原作者所有。

参考来源

  1. De Weerdt A, Janssen BG, Cox B, et al. Pre-admission air pollution exposure prolongs the duration of ventilation in intensive care patients. Intensive Care Med. 2020. PMID: 32185459. doi:10.1007/s00134-020-05999-3

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。