电阻抗断层成像引导的机械通气在急性肺损伤儿童中的应用
这项前瞻性干预试验在2个儿童重症监护病房纳入8例早期急性呼吸窘迫综合征(<72小时)患儿,连续3天采用电阻抗断层成像区域顺应性分析引导呼气末正压滴定,以急性呼吸窘迫网络高/低呼气末正压表为安全护栏,保持驱动压恒定。滴定后电阻抗断层成像分类的塌陷或过度膨胀肺区域平均减少9.1%(95%CI -13.7至-4.4,p<0.001),其中塌陷减少9.9%(95%CI -15.3至-4.5,p<0.001),过度膨胀未显著增加(0.8%,95%CI -2.9至4.5,p=0.650)。呼气末正压平均升高1.4 mbar(95%CI 0.6-2.2,p=0.008),全局呼吸系统顺应性改善1.3 mL/mbar(95%CI -0.3至3.0,p=0.026),动脉血氧分压升高17.6 mm Hg(95%CI 7.8-27.5,p=0.0039),氧合指数升高55.2 mm Hg(95%CI 27.3-83.2,p<0.001)。
要点
- 电阻抗断层成像引导呼气末正压滴定使塌陷或过度膨胀肺区域平均减少9.1%(95%CI -13.7至-4.4,p<0.001),其中塌陷减少9.9%(95%CI -15.3至-4.5,p<0.001),过度膨胀未显著增加(0.8%,95%CI -2.9至4.5,p=0.650)。
- 滴定后呼气末正压平均升高1.4 mbar(95%CI 0.6-2.2,p=0.008),全局呼吸系统顺应性改善1.3 mL/mbar(95%CI -0.3至3.0,p=0.026)。
- 动脉血氧分压升高17.6 mm Hg(95%CI 7.8-27.5,p=0.0039),氧合指数升高55.2 mm Hg(95%CI 27.3-83.2,p<0.001)。
- 方案以急性呼吸窘迫网络高/低呼气末正压表为安全护栏,保持驱动压恒定,每1小时检查区域顺应性,出现去复张时从步骤1重新开始。
适用人群与场景
- 2个儿童重症监护病房的8例早期急性呼吸窘迫综合征患儿(<72小时)。
处置流程与药物剂量
- 连续3天进行电阻抗断层成像引导的呼气末正压滴定,使用区域顺应性分析,以急性呼吸窘迫网络高/低呼气末正压表为安全护栏,保持驱动压恒定。
- 步骤1复张肺不张:以4 mbar步长增加呼气末正压。
- 步骤2减少过度膨胀:以2 mbar步长降低呼气末正压,直至电阻抗断层成像显示塌陷。
- 步骤3维持当前呼气末正压并每1小时检查区域顺应性;出现去复张时从步骤1开始。
研究设计与关键结果
- 前瞻性干预试验,2个儿童重症监护病房,8例早期急性呼吸窘迫综合征患儿(<72小时),连续3天电阻抗断层成像引导呼气末正压滴定。
- 电阻抗断层成像分类的塌陷或过度膨胀肺区域平均减少9.1%(95%CI -13.7至-4.4,p<0.001)。
- 塌陷减少9.9%(95%CI -15.3至-4.5,p<0.001),过度膨胀未显著增加(0.8%,95%CI -2.9至4.5,p=0.650)。
- 呼气末正压平均升高1.4 mbar(95%CI 0.6-2.2,p=0.008)。
- 全局呼吸系统顺应性改善1.3 mL/mbar(95%CI -0.3至3.0,p=0.026)。
- 动脉血氧分压升高17.6 mm Hg(95%CI 7.8-27.5,p=0.0039),氧合指数升高55.2 mm Hg(95%CI 27.3-83.2,p<0.001)。
证据类型、等级与局限
- 证据类型:前瞻性干预试验(概念验证)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在儿童急性呼吸窘迫综合征中,电阻抗断层成像引导的呼气末正压滴定可减少区域肺塌陷而不显著增加过度膨胀,并改善全局呼吸系统顺应性和气体交换(作者结论)。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: To provide proof-of-concept for a protocol applying a strategy of personalized mechanical ventilation in children with acute respiratory distress syndrome. Positive end-expiratory pressure and inspiratory pressure settings were optimized using real-time electrical impedance tomography aiming to maximize lung recruitment while minimizing lung overdistension.
DESIGN: Prospective interventional trial.
PATIENTS: Eight children with early acute respiratory distress syndrome (< 72 hr).
INTERVENTIONS: On 3 consecutive days, electrical impedance tomography-guided positive end-expiratory pressure titration was performed by using regional compliance analysis. The Acute Respiratory Distress Network high/low positive end-expiratory pressure tables were used as patient's safety guardrails. Driving pressure was maintained constant. Algorithm includes the following: 1) recruitment of atelectasis: increasing positive end-expiratory pressure in steps of 4 mbar; 2) reduction of overdistension: decreasing positive end-expiratory pressure in steps of 2 mbar until electrical impedance tomography shows collapse; and 3) maintaining current positive end-expiratory pressure and check regional compliance every hour. In case of derecruitment start at step 1.
MEASUREMENTS AND MAIN RESULTS: Lung areas classified by electrical impedance tomography as collapsed or overdistended were changed on average by -9.1% (95% CI, -13.7 to -4.4; p < 0.001) during titration. Collapse was changed by -9.9% (95% CI, -15.3 to -4.5; p < 0.001), while overdistension did not increase significantly (0.8%; 95% CI, -2.9 to 4.5; p = 0.650). A mean increase of the positive end-expiratory pressure level (1.4 mbar; 95% CI, 0.6-2.2; p = 0.008) occurred after titration. Global respiratory system compliance and gas exchange improved (global respiratory system compliance: 1.3 mL/mbar, 95% CI [-0.3 to 3.0], p = 0.026; Pao2: 17.6 mm Hg, 95% CI [7.8-27.5], p = 0.0039; and Pao2/Fio2 ratio: 55.2 mm Hg, 95% CI [27.3-83.2], p < 0.001, all values are change in pre vs post).
CONCLUSIONS: Electrical impedance tomography-guided positive end-expiratory pressure titration reduced regional lung collapse without significant increase of overdistension, while improving global compliance and gas exchange in children with acute respiratory distress syndrome.
参考来源
- Rosemeier I, Reiter K, Obermeier V, et al. Mechanical Ventilation Guided by Electrical Impedance Tomography in Children With Acute Lung Injury. Crit Care Explor. 2019. PMID: 32166264. doi:10.1097/CCE.0000000000000020
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。