文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

早期ARDS中微循环功能障碍与死腔通气的关系:一项假设生成性观察研究

Microcirculatory dysfunction and dead-space ventilation in early ARDS: a hypothesis-generating observational study.
PubMed 文献 · Ann Intensive Care · 2020-03-24
一句话结论早期中重度ARDS患者舌下黏膜微循环灌注指标与小血管灌注比例和微循环血流指数与死腔通气分数呈显著负相关,而呼吸力学和氧合参数与死腔通气无关。

该研究纳入42例早期中重度ARDS患者,在PEEP递减复张后设定目标为最佳呼吸系统顺应性的PEEP,稳定60分钟后记录血流动力学和呼吸力学并采集血气,通过容积二氧化碳图计算死腔通气分数(VD/VT),同时用侧流暗视野装置采集舌下微循环图像进行盲法半定量分析,24小时后重复所有测量。结果示小血管灌注比例(PPV)和微循环血流指数(MFI)在基线和24小时均与VD/VT呈显著负相关(基线Spearman rho分别为-0.76和-0.63,p<0.001;R²分别为0.63和0.48,p<0.001),PPV在基线与24小时之间的变化与同期VD/VT变化也呈显著负相关(Spearman rho=-0.66,p<0.001;R²=0.67,p<0.001),而其他呼吸、大血流动力学和氧合参数与VD/VT无相关性。作者认为舌下黏膜微循环血流异质性增加似乎与VD/VT升高相关,但微循环功能障碍与死腔通气之间是否存在因果关系需未来研究探讨。

要点

  • 在42例早期中重度ARDS患者中,舌下黏膜小血管灌注比例(PPV)与死腔通气分数(VD/VT)在基线呈显著负相关(Spearman rho=-0.76,p<0.001;R²=0.63)。
  • 微循环血流指数(MFI)与VD/VT在基线也呈显著负相关(Spearman rho=-0.63,p<0.001;R²=0.48)。
  • 24小时后PPV和MFI与VD/VT仍呈显著负相关(Spearman rho分别为-0.71和-0.65,p<0.001;R²分别为0.66和0.60,p<0.001)。
  • PPV从基线到24小时的变化与同期VD/VT变化呈显著负相关(Spearman rho=-0.66,p<0.001;R²=0.67,p<0.001)。
  • 其他呼吸力学、大血流动力学和氧合参数与VD/VT无显著相关性。

适用人群与场景

  • 连续纳入的42例早期中度及重度ARDS患者。

处置流程与药物剂量

  • PEEP设置在PEEP递减复张操作后以最佳呼吸系统顺应性为目标。
  • 稳定60分钟后记录血流动力学和呼吸力学并采集血气,通过容积二氧化碳图测量二氧化碳产量和呼气二氧化碳分数计算VD/VT。
  • 同时使用侧流暗视野装置采集舌下微循环图像进行盲法半定量分析,所有测量在24小时后重复。

研究设计与关键结果

  • 研究类型为假设生成性观察研究,样本量42例,人群为早期中度及重度ARDS患者。
  • 基线时PPV与VD/VT呈显著负相关(Spearman rho=-0.76,p<0.001;R²=0.63),MFI与VD/VT呈显著负相关(Spearman rho=-0.63,p<0.001;R²=0.48)。
  • 24小时后PPV与VD/VT呈显著负相关(Spearman rho=-0.71,p<0.001;R²=0.66),MFI与VD/VT呈显著负相关(Spearman rho=-0.65,p<0.001;R²=0.60)。
  • 基线至24小时PPV变化与同期VD/VT变化呈显著负相关(Spearman rho=-0.66,p<0.001;R²=0.67)。
  • 其他呼吸、大血流动力学和氧合参数与VD/VT无显著相关性。

证据类型、等级与局限

  • 证据类型为假设生成性观察研究。
  • 作者结论指出舌下黏膜微循环血流异质性增加似乎与VD/VT升高相关,微循环功能障碍与死腔通气之间是否存在因果关系需未来研究探讨。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为舌下黏膜微循环血流异质性增加似乎与VD/VT升高相关,而呼吸力学和氧合参数与VD/VT无关,提示在早期中重度ARDS中死腔通气增加可能反映微循环功能障碍。
  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Ventilation/perfusion inequalities impair gas exchange in acute respiratory distress syndrome (ARDS). Although increased dead-space ventilation (VD/VT) has been described in ARDS, its mechanism is not clearly understood. We sought to evaluate the relationships between dynamic variations in VD/VT and extra-pulmonary microcirculatory blood flow detected at sublingual mucosa hypothesizing that an altered microcirculation, which is a generalized phenomenon during severe inflammatory conditions, could influence ventilation/perfusion mismatching manifested by increases in VD/VT fraction during early stages of ARDS.

METHODS: Forty-two consecutive patients with early moderate and severe ARDS were included. PEEP was set targeting the best respiratory-system compliance after a PEEP-decremental recruitment maneuver. After 60 min of stabilization, hemodynamics and respiratory mechanics were recorded and blood gases collected. VD/VT was calculated from the CO2 production ([Formula: see text]) and CO2 exhaled fraction ([Formula: see text]) measurements by volumetric capnography. Sublingual microcirculatory images were simultaneously acquired using a sidestream dark-field device for an ulterior blinded semi-quantitative analysis. All measurements were repeated 24 h after.

RESULTS: Percentage of small vessels perfused (PPV) and microcirculatory flow index (MFI) were inverse and significantly related to VD/VT at baseline (Spearman's rho = - 0.76 and - 0.63, p < 0.001; R2 = 0.63, and 0.48, p < 0.001, respectively) and 24 h after (Spearman's rho = - 0.71, and - 0.65; p < 0.001; R2 = 0.66 and 0.60, p < 0.001, respectively). Other respiratory, macro-hemodynamic and oxygenation parameters did not correlate with VD/VT. Variations in PPV between baseline and 24 h were inverse and significantly related to simultaneous changes in VD/VT (Spearman's rho = - 0.66, p < 0.001; R2 = 0.67, p < 0.001).

CONCLUSION: Increased heterogeneity of microcirculatory blood flow evaluated at sublingual mucosa seems to be related to increases in VD/VT, while respiratory mechanics and oxygenation parameters do not. Whether there is a cause-effect relationship between microcirculatory dysfunction and dead-space ventilation in ARDS should be addressed in future research.

来源:Ann Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Ospina-Tascón GA, Bautista DF, Madriñán HJ, et al. Microcirculatory dysfunction and dead-space ventilation in early ARDS: a hypothesis-generating observational study. Ann Intensive Care. 2020. PMID: 32211957. doi:10.1186/s13613-020-00651-1

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。