单人救生员、双救生员及救生员加旁观者在水上救援后实施心肺复苏质量的评估:一项准实验试验
该模拟准实验研究纳入14名救生员和13名无CPR培训的 laypersons,评估水上救援疲劳对后续CPR质量的影响及旁观者参与的作用。每名救生员先进行2分钟单人CPR基线测量,随后在三次独立试验中游泳50米救援并拖回人体模型50米,之后分别由单人救生员、双救生员或救生员加旁观者进行10分钟CPR。结果显示,水上救援后单人救生员CPR与基线无显著差异;单人救生员的CPR评分和通气评分高于救生员加旁观者组;双救生员组和救生员加旁观者组的正确通气量呼吸百分比低于单人救生员组,过度通气量呼吸百分比更高;救生员加旁观者组的无血流时间更长。作者结论认为,救生员水上救援产生的疲劳对后续10分钟CPR质量无影响,未受训旁观者协助CPR不太可能有帮助。
要点
- 模拟研究中,救生员完成50米游泳救援并拖回人体模型50米后,单人实施10分钟CPR的质量与基线无显著差异。
- 单人救生员组的CPR评分和通气评分高于救生员加未受训旁观者组(p=0.027,p<0.001)。
- 双救生员组和救生员加旁观者组的正确通气量呼吸百分比低于单人救生员组(p=0.025,p=0.010),过度通气量呼吸百分比更高(p=0.007,p=0.011)。
- 救生员加旁观者组的无血流时间长于其他试验(p<0.001)。
- 作者结论:未受训旁观者协助溺水CPR不太可能有帮助。
适用人群与场景
- 模拟场景:14名救生员和13名无CPR培训的 laypersons,在泳池中完成50米游泳救援并拖回人体模型50米后实施CPR。
研究设计与关键结果
- 研究类型:模拟准实验研究,样本为14名救生员和13名无CPR培训的 laypersons。
- 干预:每名救生员先进行2分钟单人CPR基线测量;随后三次独立试验中,救生员游泳50米救援并拖回人体模型50米,之后分别由单人救生员、双救生员或救生员加无CPR培训的旁观者进行10分钟CPR。
- 基线CPR质量除按压深度和胸廓回弹外,大多数指标达标。
- 水上救援后单人救生员试验与基线相比无显著差异。
- 单人救生员组的CPR评分和通气评分高于救生员加旁观者组(p=0.027,p<0.001)。
- 双救生员组(p=0.025)和救生员加旁观者组(p=0.010)的正确通气量呼吸百分比低于单人救生员组;过度通气量呼吸百分比更高(分别为p=0.007,p=0.011)。
- 救生员加旁观者组的无血流时间长于其他试验(p<0.001)。
证据类型、等级与局限
- 证据类型:模拟准实验研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论认为,救生员水上救援产生的疲劳对后续10分钟CPR质量无影响。
- 作者结论认为,未受训旁观者协助溺水CPR不太可能有帮助。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: High-quality cardiopulmonary resuscitation (CPR) could improve survival of drowning victims. The purpose of the study is to assess the impact of fatigue caused by water rescue on subsequent CPR quality and the influence of a bystander's participation on CPR quality in a lifeguard rescue.
METHODS: This was a simulated quasi-experimental study with a sample of 14 lifeguards and 13 laypersons. Each lifeguard performed 2 min single-rescuer CPR as baseline measurement. In three separate trials, a single lifeguard swam 50 m to perform a water rescue in a pool and returned with the manikin another 50 m. After each rescue, 10 min of CPR was performed by a single lifeguard, two lifeguards or a lifeguard with a layperson with no CPR training. Paired t-test and repeated analysis of variance were used to analyse CPR quality variables.
RESULTS: Baseline CPR quality was adequate for most measures except compression depth and re-expansion. After water rescue, the single lifeguard trial showed no significant differences compared with baseline. CPR score and ventilation score of the single-lifeguard trial was higher than that of the lifeguard-bystander trial (p=0.027, p<0.001). Both the two-lifeguard trial (p=0.025), and lifeguard-bystander trial (p=0.010) had a lower percentage of breaths with correct ventilation volume and higher percentage of breaths with excessive ventilation volume (p=0.007, p=0.011, respectively) than the single-lifeguard trial. No-flow time of the lifeguard-bystander trial was longer than other trials (p<0.001).
CONCLUSIONS: Although CPR given by the lifeguard was not optimal, fatigue generated by a water rescue has no impact on the quality of subsequent CPR performed by a trained lifeguard for 10 min. Untrained bystanders assisting in CPR in a drowning event is unlikely to be helpful.
参考来源
- Li S, Kan T, Guo Z, et al. Assessing the quality of CPR performed by a single lifeguard, two lifeguards and a lifeguard with a bystander after water rescue: a quasi-experimental trial. Emerg Med J. 2020. PMID: 32201378. doi:10.1136/emermed-2018-207939
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。