文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

指尖皮肤血流变化与循环性休克患者死亡率相关

Alterations in Skin Blood Flow at the Fingertip Are Related to Mortality in Patients With Circulatory Shock.
PubMed 文献 · Crit Care Med · 2020-01-01
一句话结论循环性休克患者指尖皮肤激光多普勒热激发试验的反应(ΔSBF/ΔT)与ICU死亡率直接相关,曲线下面积达0.94,可能用于指导复苏。

这项前瞻性研究在35张床位的大学医院重症监护病房进行,纳入20名健康志愿者和70例循环性休克(持续时间<12小时,定义为需要血管升压药维持平均动脉压≥65 mmHg且有组织灌注改变征象)患者。使用皮肤激光多普勒在指尖基础温度和37°C下测量皮肤血流量,计算热激发反应(ΔSBF/ΔT),并在纳入时及6、24、48、72、96小时重复测量,同时测量毛细血管再充盈时间和外周灌注指数。结果显示,入选时患者皮肤血流量和ΔSBF/ΔT低于志愿者;幸存者基线皮肤血流量和ΔSBF/ΔT高于非幸存者;ΔSBF/ΔT的ROC曲线下面积为0.94(0.88-0.99),最佳界值≤1.25任意灌注单位/°C(敏感性88%,特异性89%),SBFBT的曲线下面积为0.83(0.73-0.93),界值≤21任意灌注单位(敏感性84%,特异性81%)。结论认为指尖皮肤血流变化与结局直接相关,这些新型监测技术可能用于指导复苏。

要点

  • 在循环性休克患者中,入选时ΔSBF/ΔT预测ICU死亡的ROC曲线下面积为0.94(0.88-0.99),界值≤1.25任意灌注单位/°C时敏感性88%、特异性89%。
  • 入选时基线皮肤血流量(SBFBT)预测ICU死亡的ROC曲线下面积为0.83(0.73-0.93),界值≤21任意灌注单位时敏感性84%、特异性81%。
  • 幸存者基线皮肤血流量为31(17-113)任意灌注单位,高于非幸存者的16(9-32)任意灌注单位(p=0.01)。
  • 幸存者ΔSBF/ΔT为4.3(1.7-10.9)任意灌注单位/s,高于非幸存者的0.9(0.4-2.9)任意灌注单位/s。
  • 幸存者毛细血管再充盈时间短于非幸存者;外周灌注指数在两组间相似。

适用人群与场景

  • 循环性休克患者,休克持续时间<12小时,定义为需要血管升压药维持平均动脉压≥65 mmHg且有组织灌注改变征象。
  • 研究在35张床位的大学医院内科-外科重症监护病房进行。
  • 另纳入20名健康志愿者作为对照。

诊断标准与关键阈值

  • 循环性休克定义:需要血管升压药维持平均动脉压≥65 mmHg且有组织灌注改变征象,持续时间<12小时。
  • ΔSBF/ΔT预测ICU死亡的最佳界值≤1.25任意灌注单位/°C(敏感性88%,特异性89%)。
  • SBFBT预测ICU死亡的最佳界值≤21任意灌注单位(敏感性84%,特异性81%)。

处置流程与药物剂量

  • 使用皮肤激光多普勒在指尖测量基础温度下皮肤血流量(SBFBT)和37°C下皮肤血流量(SBF37),每次3分钟(热激发试验)。
  • 热激发反应ΔSBF/ΔT计算公式:(SBF37-SBFBT)/(37-基础温度)。
  • 在纳入时及之后6、24、48、72、96小时重复测量皮肤血流量,同时在 contralateral 手测量毛细血管再充盈时间和外周灌注指数。

研究设计与关键结果

  • 前瞻性研究,纳入70例循环性休克患者和20名健康志愿者。
  • 入选时患者皮肤血流量和ΔSBF/ΔT低于志愿者。
  • 幸存者基线皮肤血流量31(17-113)vs 非幸存者16(9-32)任意灌注单位,p=0.01。
  • 幸存者ΔSBF/ΔT 4.3(1.7-10.9)vs 非幸存者0.9(0.4-2.9)任意灌注单位/s。
  • ΔSBF/ΔT预测ICU死亡的ROC曲线下面积0.94(0.88-0.99),界值≤1.25任意灌注单位/°C(敏感性88%,特异性89%)。
  • SBFBT预测ICU死亡的ROC曲线下面积0.83(0.73-0.93),界值≤21任意灌注单位(敏感性84%,特异性81%)。
  • 幸存者毛细血管再充盈时间短于非幸存者;外周灌注指数两组相似。

证据类型、等级与局限

  • 前瞻性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为指尖皮肤血流变化与循环性休克患者结局直接相关。
  • 作者认为这些新型监测技术可能用于指导复苏。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: Skin blood flow is rapidly altered during circulatory shock and may remain altered despite apparent systemic hemodynamic stabilization. We evaluated whether changes in skin blood flow during circulatory shock were related to survival.

DESIGN: Prospective study.

SETTING: Thirty-five-bed medical-surgical university hospital department of intensive care.

SUBJECTS: Twenty healthy volunteers and 70 patients with circulatory shock (< 12 hr duration), defined as the need for vasopressors to maintain mean arterial pressure greater than or equal to 65 mm Hg and signs of altered tissue perfusion.

INTERVENTIONS: We assessed skin blood flow using skin laser Doppler on the fingertip for 3 minutes at basal temperature (SBFBT) and at 37°C (SBF37) (thermal challenge test) once in volunteers and at the time of inclusion and after 6, 24, 48, 72, and 96 hours in patients with shock. Capillary refill time and peripheral perfusion index were measured at the same time points on the contralateral hand.

MEASUREMENTS AND MAIN RESULTS: The thermal challenge response (ΔSBF/ΔT) was calculated using the following formula: (SBF37-SBFBT)/(37-basal temperature). Area under the receiver operating characteristic curves were calculated to evaluate variables predictive of ICU mortality. At inclusion, skin blood flow and ΔSBF/ΔT were lower in patients than in volunteers. Baseline skin blood flow (31 [17-113] vs 16 [9-32] arbitrary perfusion units; p = 0.01) and ΔSBF/ΔT (4.3 [1.7-10.9] vs 0.9 [0.4-2.9] arbitrary perfusion unit/s) were greater in survivors than in nonsurvivors. Capillary refill time was shorter in survivors than in nonsurvivors; peripheral perfusion index was similar in the two groups. ΔSBF/ΔT (area under the receiver operating characteristic curve 0.94 [0.88-0.99]) and SBFBT (area under the receiver operating characteristic curve 0.83 [0.73-0.93]) had the best predictive value for ICU mortality with cutoff values less than or equal to 1.25 arbitrary perfusion unit/°C (sensitivity 88%, specificity 89%) and less than or equal to 21 arbitrary perfusion unit (sensitivity 84%, specificity 81%), respectively.

CONCLUSIONS: Alterations in fingertip skin blood flow can be evaluated using a laser Doppler thermal challenge technique in patients with circulatory shock and are directly related to outcome. These novel monitoring techniques could potentially be used to guide resuscitation.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Mongkolpun W, Orbegozo D, Cordeiro CPR, et al. Alterations in Skin Blood Flow at the Fingertip Are Related to Mortality in Patients With Circulatory Shock. Crit Care Med. 2020. PMID: 32205589. doi:10.1097/CCM.0000000000004177

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。