改良容积二氧化碳图衍生参数:猪模型中监测心肺复苏效能的潜在稳定指标
该随机交叉猪实验纳入12头雄性家猪,经历4分钟未处理心室颤动后行机械心肺复苏,比较四种5分钟通气策略对V'CO2 kg-1与PETCO2的影响。不同通气类型对V'CO2 kg-1及血流动力学无显著影响,而PETCO2受通气类型和冠状动脉灌注压显著影响,随呼吸频率增加线性下降,潮气量从10增至20 mL min-1时PETCO2从20.42±9.51降至16.16±5.07。V'CO2 kg-1在三种呼吸频率水平间无显著差异。V'CO2 kg-1与PETCO2区分存活与非存活动物的AUC分别为0.80和0.71。作者认为V'CO2 kg-1在过度通气时监测CPR质量优于PETCO2,预测ROSC能力良好。
要点
- 在猪心室颤动模型中,不同通气类型对V'CO2 kg-1无显著影响(P=0.274),而PETCO2受通气类型显著影响(P<0.05)。
- PETCO2随呼吸频率增加呈线性下降(P<0.05),潮气量从10增至20 mL min-1时从20.42±9.51降至16.16±5.07(P<0.05)。
- V'CO2 kg-1与PETCO2区分存活与非存活动物的AUC分别为0.80和0.71。
- 作者认为V'CO2 kg-1在过度通气时监测CPR质量优于PETCO2,预测ROSC能力良好。
适用人群与场景
- 雄性家猪,4分钟未处理心室颤动后接受机械心肺复苏的动物模型
研究设计与关键结果
- 随机交叉动物实验,纳入12头雄性家猪,经历4分钟未处理心室颤动后行机械心肺复苏,每头动物在两个时段各接受四次5分钟通气试验后接高级生命支持,中间设5分钟洗脱期。
- 不同通气类型对V'CO2 kg-1或血流动力学无显著影响,但PETCO2受通气类型和冠状动脉灌注压显著影响(P<0.05)。
- PETCO2均值随呼吸频率增加呈线性下降(P<0.05);潮气量从10增至20 mL min-1时,PETCO2从20.42±9.51降至16.16±5.07(P<0.05)。
- 三种呼吸频率水平间V'CO2 kg-1无显著差异(P=0.274);事后分析显示双倍潮气量过度通气时V'CO2 kg-1最高值与正常通气及三倍呼吸频率过度通气间差异显著(P<0.05)。
- V'CO2 kg-1与PETCO2区分存活与非存活动物的AUC分别为0.80和0.71。
证据类型、等级与局限
- 证据类型:随机交叉动物实验(猪模型)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,在过度通气时V'CO2 kg-1监测CPR质量优于PETCO2;在通气状态变化时,V'CO2 kg-1对ROSC具有良好的预测能力。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
AIM: We aimed to investigate whether the ability of the volumetric capnography-derived parameter, the volume of CO2 eliminated per minute and per kg body weight (V'CO2 kg-1), in monitoring the quality of CPR and predicting the return of spontaneous circulation (ROSC) remains undisturbed by hyperventilation.
METHODS: This randomised crossover study included 12 male domestic pigs. After 4 min of untreated ventricular fibrillation, mechanical CPR was administered. Following 5-min washout periods, each animal underwent two sessions of experiments; four 5-min ventilation trials followed by advanced life support, consecutively in the two sessions.
RESULTS: Different ventilation types had no significant impact on V'CO2 kg-1 or haemodynamics. However, PETCO2 was significantly affected by the ventilation type and coronary perfusion pressure (P < 0.05). The means ± standard deviations of PETCO2 decreased linearly with an increase in the respiratory rate (RR) (P < 0.05). The PETCO2 decreased from 20.42 ± 9.51 to 16.16 ± 5.07 (P < 0.05) as the tidal volume increased from 10 to 20 mL min-1. No significant differences in V'CO2 kg-1 were observed between the three RR levels of ventilation types (P = 0.274). Post hoc analysis demonstrated a significant difference between the highest value of V'CO2 kg-1 in double tidal volume hyperventilation and normal ventilation and triple respiratory rate hyperventilation (P < 0.05). The AUC for V'CO2 kg-1 and PETCO2 in discriminating between survivors and non-survivors was 0.80 and 0.71, respectively.
CONCLUSIONS: V'CO2 kg-1 performs better than PETCO2 in monitoring the quality of CPR during hyperventilation. In predicting ROSC during variations in a ventilation state, V'CO2 kg-1 has good predictive ability.
参考来源
- Xu J, Yu X, Zhang L, et al. Modified volumetric capnography-derived parameter: A potentially stable indicator in monitoring cardiopulmonary resuscitation efficacy in a porcine model. Resuscitation. 2020. PMID: 32220582. doi:10.1016/j.resuscitation.2020.02.039
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。