文献速递复苏、休克与脓毒症心脑血管急症

控制性渐进抬高比最佳角度更能最大化猪心脏骤停模型中头高位心肺复苏的脑灌注压

Controlled progressive elevation rather than an optimal angle maximizes cerebral perfusion pressure during head up CPR in a swine model of cardiac arrest.
PubMed 文献 · Resuscitation · 2020-02-27
一句话结论猪心脏骤停模型中,头高位心肺复苏无最佳角度,控制性渐进抬高(20°→30°→40°)比固定角度更能提高脑灌注压。

研究在麻醉猪心室颤动8分钟后行主动加压-减压心肺复苏联合阻抗阈值装置,先比较20°、30°、40°头高位角度(研究A,18头猪),未发现最佳角度,30°与40°脑灌注压相当(44±22 vs 47±26 mmHg,p=0.18)。基于研究A的序列效应,研究B比较20°→30°→40°与40°→30°→20°两种序列,心肺复苏17分钟后渐进抬高序列脑灌注压更高(60±17 vs 33±18 mmHg,p=0.035)。结论认为控制性渐进抬高比绝对角度或高度更有益于最大化脑灌注压,需进一步研究确定最佳上升速率。

要点

  • 猪心脏骤停模型中,头高位心肺复苏20°、30°、40°固定角度未显示最佳角度,30°与40°脑灌注压相当(44±22 vs 47±26 mmHg,p=0.18)。
  • 研究B中,心肺复苏17分钟后,20°→30°→40°渐进抬高序列脑灌注压高于40°→30°→20°序列(60±17 vs 33±18 mmHg,p=0.035)。
  • 作者结论认为,控制性渐进抬高头胸部比追求绝对角度或高度更能最大化脑灌注压。
  • 作者指出需进一步研究确定头高位主动加压-减压心肺复苏联合阻抗阈值装置时最佳的上升速率。

适用人群与场景

  • 麻醉猪心室颤动模型,8分钟未治疗心室颤动后接受主动加压-减压心肺复苏联合阻抗阈值装置。

处置流程与药物剂量

  • 研究A:在8分钟未治疗心室颤动后,行主动加压-减压心肺复苏联合阻抗阈值装置,每5分钟随机切换20°、30°、40°头高位角度。
  • 研究B:按相似方案随机分为20°→30°→40°或40°→30°→20°两种头高位角度序列。

研究设计与关键结果

  • 研究A为猪模型,18头猪,比较20°、30°、40°头高位角度,未观察到最佳角度;30°与40°脑灌注压等效(44±22 vs 47±26 mmHg,p=0.18)。
  • 研究A中40°头高位在心肺复苏最后5分钟时脑灌注压似乎更高,提示序列效应。
  • 研究B为猪模型,心肺复苏17分钟后,20°→30°→40°序列脑灌注压高于40°→30°→20°序列(60±17 vs 33±18 mmHg,p=0.035)。

证据类型、等级与局限

  • 证据类型:动物实验(猪心脏骤停模型)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在心肺复苏中控制性渐进抬高头胸部比绝对角度或高度更能最大化脑灌注压。
  • 作者指出需进一步研究确定头高位主动加压-减压心肺复苏联合阻抗阈值装置时最佳的上升速率。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM OF THE STUDY: Elevation of the head and thorax (HUP) during cardiopulmonary resuscitation (CPR) has been shown to double brain blood flow with increased cerebral perfusion pressures (CerPP) after active compression-decompression (ACD) CPR with an impedance threshold device (ITD). However, the optimal angle for HUP CPR is unknown.

METHODS: In Study A, different angles were assessed (20°, 30°, 40°), each randomized over 5-min periods of ACD + ITD CPR, after 8 min of untreated ventricular fibrillation in an anesthetized swine model. Based upon Study A, Study B was performed, where animals were randomized to 1 of 2 sequences: 20°, 30°, 40° or 40°, 30°, 20° with a similar protocol. The primary endpoint was CerPP for both studies.

RESULTS: In Study A, no optimal HUP angle was observed in 18 pigs. CerPPs for 30° and 40° (mmHg, mean ± SD) were equivalent (44 ± 22 and 47 ± 26, p = 0.18). However, CerPP appeared higher when 40° HUP was performed during the last 5-min of CPR, suggestive of a sequence effect. For Study B, after 17 min of CPR, CerPP (mmHg) were higher with the 20°, 30°, 40° sequence: 60 ± 17 versus 33 ± 18 (p = 0.035).

CONCLUSIONS: No optimal HUP CPR angle was observed. However, controlled progressive elevation of the head and thorax during CPR is more beneficial than an absolute angle or height to maximize CerPP. Further studies are needed to determine the optimal rate of rise during HUP ACD + ITD CPR.

INSTITUTIONAL PROTOCOL NUMBER: 17-06.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Moore JC, Salverda B, Lick M, et al. Controlled progressive elevation rather than an optimal angle maximizes cerebral perfusion pressure during head up CPR in a swine model of cardiac arrest. Resuscitation. 2020. PMID: 32114071. doi:10.1016/j.resuscitation.2020.02.023

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。