呼吸机相关事件诊断呼吸机相关下呼吸道感染的准确性
本研究为回顾性研究,在5个10张床位的ICU开展,为期2年,共纳入1059例患者(15029个呼吸机日),前瞻性诊断呼吸机相关下呼吸道感染(VA-LRTI,包括VAT和VAP),评估VAE与VA-LRTI的一致性。结果:诊断VAP 268例(17.8/1000呼吸机日)、VAT 127例(8.5/1000呼吸机日)、VAE 262例(17.4/1000呼吸机日);VAT与VAE无一致性,VAP与VAE一致性差(k=0.12,95%CI 0.03-0.20)。VAE和VA-LRTI均与机械通气时间、ICU住院时间和总住院时间显著延长相关;多因素分析中VAP、VAT和VAE与死亡率均无显著相关。结论:VAE不能准确替代VA-LRTI诊断,VAE与不良结局相关但非死亡独立危险因素。
要点
- 在5个ICU的1059例患者中,VAE与VAP一致性差(k=0.12,95%CI 0.03-0.20),与VAT无一致性。
- VAP发生率17.8/1000呼吸机日,VAT 8.5/1000呼吸机日,VAE 17.4/1000呼吸机日,VAE不能区分VAP与VAT。
- VAE和VA-LRTI均与机械通气时间、ICU及总住院时间显著延长相关。
- 多因素分析中VAP、VAT和VAE与ICU死亡率均无显著相关。
适用人群与场景
- 在5个10张床位的教学医院ICU中,为期2年收治的机械通气患者,共1059例(15029个呼吸机日)。
诊断标准与关键阈值
- VA-LRTI包括呼吸机相关气管支气管炎(VAT)和呼吸机相关肺炎(VAP),均为前瞻性诊断。
- VAE根据呼吸机相关事件标准诊断(原文未详述具体标准)。
研究设计与关键结果
- 研究类型:回顾性研究,在5个10张床位的ICU开展,为期2年,共纳入1059例患者(15029个呼吸机日)。
- 诊断VAP 268例(17.8/1000呼吸机日)、VAT 127例(8.5/1000呼吸机日)、VAE 262例(17.4/1000呼吸机日)。
- VAT与VAE无一致性;VAP与VAE一致性差(k=0.12,95%CI 0.03-0.20)。
- VAE和VA-LRTI均与机械通气时间、ICU住院时间和总住院时间显著延长相关。
- 多因素分析中,VAP、VAT和VAE与死亡率均无显著相关。
证据类型、等级与局限
- 证据类型:回顾性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- VAE与VAP一致性差、与VAT无一致性,作者认为VAE不能准确替代VA-LRTI诊断。
- VAE与机械通气时间和住院时间延长相关,但与ICU死亡率无显著相关,作者指出VAE与不良结局相关但非死亡独立危险因素。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: The aim of this study was to investigate the concordance between ventilator-associated events (VAE) and ventilator-associated lower respiratory tract infections (VA-LRTI), and their impact on outcome.
METHODS: This retrospective study was performed in five 10-bed ICUs of a teaching hospital, during a 2-year period. Ventilator-associated lower respiratory tract infections (VA-LRTI), including ventilator-associated tracheobronchitis (VAT) and ventilator-associated pneumonia (VAP) were prospectively diagnosed. The agreement between VAE, VAT and VAP was assessed by k statistics.
RESULTS: A total of 1059 patients (15,029 ventilator-days) were included. 268 VAP (17.8 per 1000 ventilator-days), 127 VAT (8.5 per 1000 ventilator-days) and 262 VAE (17.4 per 1000 ventilator-days) were diagnosed. There was no agreement between VAT and VAE, and the agreement was poor between VAP and VAE (k = 0.12, 95% CI 0.03-0.20). VAE and VA-LRTI were associated with significantly longer duration of mechanical ventilation, ICU and hospital length of stay. VAP, VAT and VAE were not significantly associated with mortality in multivariate analysis.
CONCLUSIONS: The agreement was poor between VAE and VAP. No agreement was found between VAE and VAT. VAE episodes were significantly associated with longer duration of mechanical ventilation and length of stay, but not with ICU mortality.
参考来源
- Pouly O, Lecailtel S, Six S, et al. Accuracy of ventilator-associated events for the diagnosis of ventilator-associated lower respiratory tract infections. Ann Intensive Care. 2020. PMID: 31932982. doi:10.1186/s13613-020-0624-6
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。