文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

欧洲裔人群中脓毒症相关急性呼吸窘迫综合征的全基因组关联研究

Sepsis-associated acute respiratory distress syndrome in individuals of European ancestry: a genome-wide association study.
PubMed 文献 · Lancet Respir Med · 2020-01-23
一句话结论FLT1基因常见变异rs9508032与欧洲裔人群脓毒症相关ARDS易感性相关(OR 0.61),支持VEGF信号通路在ARDS发病中的作用。

本研究为病例对照全基因组关联研究(GWAS),纳入1935例欧洲裔个体,以脓毒症相关ARDS患者为病例、脓毒症无ARDS患者为对照。发现阶段纳入2002年1月至2017年1月西班牙ICU网络收治的672例患者,复制阶段纳入MESSI队列(美国,2008年9月22日至2017年11月30日)及SepNet的VISEP试验(2003年4月1日至2005年6月30日)和MAXSEP试验(2007年10月1日至2010年3月31日)共1345例个体。Meta分析发现FLT1基因内rs9508032与脓毒症相关ARDS易感性全基因组显著相关(OR 0.61,95%CI 0.41-0.91,p=5.18×10⁻⁸)。功能实验显示该变异区域作为FLT1启动子沉默子,保护性等位基因进一步降低启动子活性(p=0.0047)。文献挖掘验证VEGFA与ARDS相关(OR 0.55,95%CI 0.41-0.73,p=4.69×10⁻⁵)。

要点

  • 在欧洲裔人群中,FLT1基因rs9508032与脓毒症相关ARDS易感性全基因组显著相关(OR 0.61,95%CI 0.41-0.91,p=5.18×10⁻⁸)。
  • rs9508032所在区域作为FLT1启动子沉默子,ARDS保护性等位基因进一步降低启动子活性(p=0.0047)。
  • 文献挖掘验证VEGFA与ARDS相关(OR 0.55,95%CI 0.41-0.73,p=4.69×10⁻⁵)。
  • 研究支持血管内皮生长因子信号通路在ARDS发病中起作用,VEGFR-1为潜在治疗靶点。

适用人群与场景

  • 欧洲裔脓毒症患者,病例为脓毒症相关ARDS患者,对照为脓毒症无ARDS患者。
  • 发现阶段为2002年1月至2017年1月西班牙ICU网络收治的患者,复制阶段为MESSI队列(美国,2008年9月22日至2017年11月30日)及SepNet的VISEP试验(2003年4月1日至2005年6月30日)和MAXSEP试验(2007年10月1日至2010年3月31日)的个体。

研究设计与关键结果

  • 研究类型为病例对照全基因组关联研究(GWAS),纳入1935例欧洲裔个体,病例为脓毒症相关ARDS患者,对照为脓毒症无ARDS患者。
  • 发现阶段672例西班牙ICU患者,复制阶段1345例来自MESSI队列(美国)及VISEP和MAXSEP试验(德国)。
  • 发现FLT1基因内rs9508032与脓毒症相关ARDS易感性全基因组显著相关(OR 0.61,95%CI 0.41-0.91,p=5.18×10⁻⁸)。
  • 含哨兵变异及其最佳代理的区域作为FLT1启动子沉默子,ARDS保护性等位基因进一步降低启动子活性(p=0.0047)。
  • 文献挖掘验证VEGFA与ARDS相关(OR 0.55,95%CI 0.41-0.73,p=4.69×10⁻⁵)。

证据类型、等级与局限

  • 证据类型为病例对照全基因组关联研究(GWAS),未报告证据等级。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,FLT1基因常见变异与脓毒症相关ARDS相关,研究结果支持VEGF信号通路在ARDS发病中起作用,并确定VEGFR-1为潜在治疗靶点。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Acute respiratory distress syndrome (ARDS) is a lung inflammatory process caused mainly by sepsis. Most previous studies that identified genetic risks for ARDS focused on candidates with biological relevance. We aimed to identify novel genetic variants associated with ARDS susceptibility and to provide complementary functional evidence of their effect in gene regulation.

METHODS: We did a case-control genome-wide association study (GWAS) of 1935 European individuals, using patients with sepsis-associated ARDS as cases and patients with sepsis without ARDS as controls. The discovery stage included 672 patients admitted into a network of Spanish intensive care units between January, 2002, and January, 2017. The replication stage comprised 1345 individuals from two independent datasets from the MESSI cohort study (Sep 22, 2008-Nov 30, 2017; USA) and the VISEP (April 1, 2003-June 30, 2005) and MAXSEP (Oct 1, 2007-March 31, 2010) trials of the SepNet study (Germany). Results from discovery and replication stages were meta-analysed to identify association signals. We then used RNA sequencing data from lung biopsies, in-silico analyses, and luciferase reporter assays to assess the functionallity of associated variants.

FINDINGS: We identified a novel genome-wide significant association with sepsis-associated ARDS susceptibility (rs9508032, odds ratio [OR] 0·61, 95% CI 0·41-0·91, p=5·18 × 10-8) located within the Fms-related tyrosine kinase 1 (FLT1) gene, which encodes vascular endothelial growth factor receptor 1 (VEGFR-1). The region containing the sentinel variant and its best proxies acted as a silencer for the FLT1 promoter, and alleles with protective effects in ARDS further reduced promoter activity (p=0·0047). A literature mining of all previously described ARDS genes validated the association of vascular endothelial growth factor A (VEGFA; OR 0·55, 95% CI 0·41-0·73; p=4·69 × 10-5).

INTERPRETATION: A common variant within the FLT1 gene is associated with sepsis-associated ARDS. Our findings support a role for the vascular endothelial growth factor signalling pathway in ARDS pathogenesis and identify VEGFR-1 as a potential therapeutic target.

FUNDING: Instituto de Salud Carlos III, European Regional Development Funds, Instituto Tecnológico y de Energías Renovables.

来源:Lancet Respir Med,查看原文。版权归原作者所有。

参考来源

  1. Guillen-Guio B, Lorenzo-Salazar JM, Ma SF, et al. Sepsis-associated acute respiratory distress syndrome in individuals of European ancestry: a genome-wide association study. Lancet Respir Med. 2020. PMID: 31982041. doi:10.1016/S2213-2600(19)30368-6

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。