文献速递重症综合管理与镇静镇痛

急诊医学中的心率与心率变异性

Heart rate and heart rate variability in emergency medicine.
PubMed 文献 · Am J Emerg Med · 2019-11-18
一句话结论急诊医学住院医师在重症监护班次中佩戴腕式设备连续监测心率,发现心率显著升高,提示发作性心动过速。

本研究旨在探讨急诊医学住院医师在标准急诊班次中的心率趋势,以评估值班期间所经历压力的频率和严重程度。研究使用Empatica E4腕式生理监测设备,对31名同意参与的急诊医学住院医师在典型重症监护班次中进行心率评估。结果显示,31个重症监护班次中,每个班次的心率平均范围为53.9-162.7次/分,所有班次总体心率范围为49-202.7次/分;每个班次平均出现10.2次120-129.9次/分峰值、11.3次130-159.9次/分峰值及1.06次160次/分以上峰值;心率超过130次/分的平均持续时间为660.6秒/班次;31个班次中仅2个班次无心率超过130次/分的加速。结论认为,使用腕式设备连续监测急诊医学住院医师在标准重症监护班次中的心率,发现心率显著升高,提示发作性心动过速。

要点

  • 31名急诊医学住院医师在31个重症监护班次中佩戴Empatica E4腕式设备连续监测心率。
  • 每个班次心率平均范围为53.9-162.7次/分,所有班次总体心率范围为49-202.7次/分。
  • 每个班次平均出现10.2次120-129.9次/分峰值、11.3次130-159.9次/分峰值、1.06次160次/分以上峰值。
  • 心率超过130次/分的平均持续时间为660.6秒/班次;31个班次中仅2个班次无心率超过130次/分的加速。
  • 作者认为该心率显著升高提示发作性心动过速,可能反映值班期间的压力。

适用人群与场景

  • 急诊医学住院医师(31名同意参与者)在典型重症监护班次中。

研究设计与关键结果

  • 研究类型为使用腕式设备连续监测心率的观察性研究,样本量为31名急诊医学住院医师的31个重症监护班次。
  • 每个班次心率平均范围为53.9-162.7次/分,所有班次总体心率范围为49-202.7次/分。
  • 每个班次平均出现10.2次120-129.9次/分峰值、11.3次130-159.9次/分峰值、1.06次160次/分以上峰值。
  • 心率超过130次/分的平均持续时间为660.6秒/班次;31个班次中仅2个班次无心率超过130次/分的加速。

证据类型、等级与局限

  • 证据类型为观察性研究(使用Empatica E4腕式设备连续监测),样本量31名住院医师、31个班次。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,使用腕式设备连续监测急诊医学住院医师在标准重症监护班次中的心率,发现心率显著升高,提示发作性心动过速。
  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Tachycardia may be indicative of mental stress, which in turn can decrease performance, reduce information processing capacity, and hinder memory recall. The objective of this study is to examine heart rate trends present among emergency medicine trainees over a standard emergency room shift to measure the frequency and severity of stress experienced while on shift.

METHODS: We assessed heart rate in emergency medicine residents using the Empatica E4 device, a mobile wrist-worn physiological monitor. The 31 consenting residents received training in wearing the monitor and uploading the data during a typical critical care shift. Data was deindividualized, compiled, and analyzed with descriptive statistics using Microsoft Excel.

RESULTS: Data collected from 31 critical care shifts illustrated that the mean range in HR was 53.9-162.7 bpm per shift and the overall range in HR across all shifts was 49-202.7 bpm. There was a mean of 10.2 peaks in the 120-129.9 bpm range, 11.3 peaks within 130-159.9 bpm, and 1.06 peaks above 160 bpm per shift. The mean length of time that HR rose above 130 bpm was 660.6 s per shift. Only 2 of the 31 shifts examined did not have any accelerations above 130 bpm.

CONCLUSIONS: Continuous monitoring of HR in emergency medicine residents during standard critical care shifts using a wrist-worn device found marked elevations suggestive of episodic tachycardia.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Jenks S, Frank Peacock W, Cornelius AP, et al. Heart rate and heart rate variability in emergency medicine. Am J Emerg Med. 2019. PMID: 31836346. doi:10.1016/j.ajem.2019.10.035

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。