文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

实验性肺损伤中机械通气将血液重新分布至通气不良区域

Mechanical Ventilation Redistributes Blood to Poorly Ventilated Areas in Experimental Lung Injury.
PubMed 文献 · Crit Care Med · 2020-01-01
一句话结论在实验性肺不张伴潮式复张/萎陷极少的条件下,机械吸气将血容量从通气良好区域重分布至通气不良区域,使氧合恶化。

该临床前研究在7头28.7 kg(SD 2.1 kg)麻醉猪的生理盐水灌洗表面活性物质耗竭肺损伤模型中,将呼气末正压于0至20 cm H2O间调整以诱导不同程度肺不张,用动态双能CT获取膈旁切面气体与血容量分数并按肺组织质量标准化。按呼气末肺不张质量分数分组(<20%、20-40%、≥40%),在≥40%组潮式复张/萎陷小于肺质量7%。结果显示该组吸气时非重力依赖区标准化气量增加(818 µL/g,95%CI 729-908 µL/g)大于重力依赖区(149 µL/g,120-178 µL/g),非重力依赖区标准化血容量减少(29 µL/g,12-46 µL/g)、重力依赖区增加(39 µL/g,30-48 µL/g)。重力依赖区血容量增加与PaO2/FIO2比值负相关(ρ=-0.77),呼气末肺不张质量分数亦与PaO2/FIO2负相关(ρ=-0.93)。

要点

  • 在呼气末肺不张质量分数≥40%且潮式复张/萎陷<7%肺质量的实验性肺不张中,吸气使非重力依赖区标准化气量增加818 µL/g(95%CI 729-908 µL/g),远大于重力依赖区的149 µL/g(120-178 µL/g)。
  • 同一组吸气时非重力依赖区标准化血容量减少29 µL/g(95%CI 12-46 µL/g),而重力依赖区增加39 µL/g(30-48 µL/g),即血液被重新分布至通气不良区域。
  • 吸气相关标准化气量与血容量变化在呼气末肺不张质量分数≥40%组(r=0.56)和20-40%组(r=0.40)呈负相关,在<20%组无相关(r=0.01)。
  • 重力依赖区标准化血容量增加与PaO2/FIO2比值负相关(ρ=-0.77),呼气末肺不张质量分数与PaO2/FIO2比值负相关(ρ=-0.93)。

适用人群与场景

  • 7头麻醉猪,体重28.7 kg(SD 2.1 kg),接受生理盐水灌洗表面活性物质耗竭肺损伤模型。
  • 研究在科研实验室进行,为临床前研究。

诊断标准与关键阈值

  • 按呼气末肺不张质量分数将通气条件分为<20%、20-40%和≥40%三组。
  • 呼气末肺不张质量分数≥40%组中,潮式复张/萎陷小于肺质量7%。

处置流程与药物剂量

  • 呼气末正压在0至20 cm H2O之间调整,以诱导不同程度的肺不张。

研究设计与关键结果

  • 临床前研究,7头麻醉猪,生理盐水灌洗表面活性物质耗竭肺损伤模型,呼气末正压0至20 cm H2O调整以诱导不同水平肺不张,动态双能CT获取膈旁切面气体与血容量分数。
  • 呼气末肺不张质量分数≥40%组潮式复张/萎陷小于肺质量7%;该组吸气时非重力依赖区标准化气量增加818 µL/g(95%CI 729-908 µL/g),重力依赖区增加149 µL/g(120-178 µL/g)。
  • 该组吸气时非重力依赖区标准化血容量减少29 µL/g(95%CI 12-46 µL/g),重力依赖区增加39 µL/g(30-48 µL/g)。
  • 吸气相关标准化气量与血容量变化在呼气末肺不张质量分数≥40%组(r=0.56)和20-40%组(r=0.40)呈负相关,在<20%组无相关(r=0.01)。
  • 重力依赖区标准化血容量增加与PaO2/FIO2比值负相关(ρ=-0.77),呼气末肺不张质量分数与PaO2/FIO2比值负相关(ρ=-0.93)。

证据类型、等级与局限

  • 证据类型:临床前研究(动物实验)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在潮式复张/萎陷极少的实验性肺不张中,机械吸气 breaths 将血容量从通气良好区域重新分布,使PaO2/FIO2恶化。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: Determine the intra-tidal regional gas and blood volume distributions at different levels of atelectasis in experimental lung injury. Test the hypotheses that pulmonary aeration and blood volume matching is reduced during inspiration in the setting of minimal tidal recruitment/derecruitment and that this mismatching is an important determinant of hypoxemia.

DESIGN: Preclinical study.

SETTING: Research laboratory.

SUBJECTS: Seven anesthetized pigs 28.7 kg (SD, 2.1 kg).

INTERVENTIONS: All animals received a saline-lavage surfactant depletion lung injury model. Positive end-expiratory pressure was varied between 0 and 20 cm H2O to induce different levels of atelectasis.

MEASUREMENTS AND MAIN RESULTS: Dynamic dual-energy CT images of a juxtadiaphragmatic slice were obtained, gas and blood volume fractions within three gravitational regions calculated and normalized to lung tissue mass (normalized gas volume and normalized blood volume, respectively). Ventilatory conditions were grouped based upon the fractional atelectatic mass in expiration (< 20%, 20-40%, and ≥ 40%). Tidal recruitment/derecruitment with fractional atelectatic mass in expiration greater than or equal to 40% was less than 7% of lung mass. In this group, inspiration-related increase in normalized gas volume was greater in the nondependent (818 µL/g [95% CI, 729-908 µL/g]) than the dependent region (149 µL/g [120-178 µL/g]). Normalized blood volume decreased in inspiration in the nondependent region (29 µL/g [12-46 µL/g]) and increased in the dependent region (39 µL/g [30-48 µL/g]). Inspiration-related changes in normalized gas volume and normalized blood volume were negatively correlated in fractional atelectatic mass in expiration greater than or equal to 40% and 20-40% groups (r = 0.56 and 0.40), but not in fractional atelectatic mass in expiration less than 20% group (r = 0.01). Both the increase in normalized blood volume in the dependent region and fractional atelectatic mass in expiration negatively correlated with PaO2/FIO2 ratio (ρ = -0.77 and -0.93, respectively).

CONCLUSIONS: In experimental atelectasis with minimal tidal recruitment/derecruitment, mechanical inspiratory breaths redistributed blood volume away from well-ventilated areas, worsening PaO2/FIO2.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Cronin JN, Crockett DC, Farmery AD, et al. Mechanical Ventilation Redistributes Blood to Poorly Ventilated Areas in Experimental Lung Injury. Crit Care Med. 2020. PMID: 31809278. doi:10.1097/CCM.0000000000004141

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。