文献速递心脑血管急症重症综合管理与镇静镇痛

心脏骤停后12和72小时神经电生理预测良好与不良神经功能结局:ProNeCA多中心前瞻性研究

Neurophysiology for predicting good and poor neurological outcome at 12 and 72 h after cardiac arrest: The ProNeCA multicentre prospective study.
PubMed 文献 · Resuscitation · 2019-11-29
一句话结论心脏骤停后昏迷患者,12小时脑电图和体感诱发电位预测神经功能结局特异性达100%,72小时不良模式预测不良结局特异性100%且敏感性高,联合后敏感性增至79%。

这项多中心前瞻性预后研究纳入351例心脏骤停后昏迷患者,134例(38%)为良好神经功能结局(CPC 1-3)。在复苏后12小时,连续、近乎连续和低电压脑电图模式预测良好结局敏感性71%[61-80]%,等电位脑电图和双侧缺失/缺失-病理性波幅(AA/AP)皮质体感诱发电位模式预测不良结局敏感性分别为14%[8-21]%和59%[50-68]%,所有预测指标特异性均为100%[97-100]%。在72小时,等电位、抑制或爆发-抑制脑电图模式及AA/AP体感诱发电位模式预测不良结局特异性均为100%[97-100]%,敏感性分别为63%[55-70]%和66%[58-74]%,两者联合后预测不良结局敏感性增至79%。所有患者均未进行生命维持治疗撤除。

要点

  • 心脏骤停后昏迷患者,12小时脑电图连续、近乎连续和低电压模式预测良好神经功能结局(CPC 1-3)敏感性71%[61-80]%,特异性100%[97-100]%。
  • 12小时等电位脑电图预测不良结局(CPC 4-5)敏感性14%[8-21]%,AA/AP体感诱发电位模式敏感性59%[50-68]%,特异性均100%[97-100]%。
  • 72小时等电位、抑制或爆发-抑制脑电图模式预测不良结局特异性100%[97-100]%,敏感性63%[55-70]%。
  • 72小时AA/AP体感诱发电位模式预测不良结局特异性100%[97-100]%,敏感性66%[58-74]%。
  • 72小时脑电图与体感诱发电位联合预测不良结局敏感性增至79%。

适用人群与场景

  • 心脏骤停复苏后昏迷患者,纳入351例,其中134例(38%)为良好神经功能结局(CPC 1-3)。
  • 所有患者均未进行生命维持治疗撤除。

诊断标准与关键阈值

  • 神经功能结局定义:良好为大脑功能分级(CPC)1-3,不良为CPC 4-5,评估时间为6个月。
  • 脑电图按美国临床神经生理学会术语分类。
  • 体感诱发电位根据皮质反应的存在和波幅分级。

研究设计与关键结果

  • 多中心前瞻性预后研究,纳入351例心脏骤停后昏迷患者,134例(38%)为良好神经功能结局(CPC 1-3)。
  • 12小时:连续、近乎连续和低电压脑电图模式预测良好结局敏感性71%[61-80]%;等电位脑电图预测不良结局敏感性14%[8-21]%;AA/AP体感诱发电位模式预测不良结局敏感性59%[50-68]%;所有预测指标特异性均为100%[97-100]%。
  • 72小时:等电位、抑制或爆发-抑制脑电图模式预测不良结局敏感性63%[55-70]%,特异性100%[97-100]%;AA/AP体感诱发电位模式预测不良结局敏感性66%[58-74]%,特异性100%[97-100]%。
  • 72小时脑电图与体感诱发电位联合预测不良结局敏感性增至79%。

证据类型、等级与局限

  • 证据类型:多中心前瞻性预后研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在心脏骤停后昏迷患者中,12小时脑电图和体感诱发电位可分别以100%特异性预测良好和不良神经功能结局。
  • 72小时不良脑电图和体感诱发电位模式以100%特异性和高敏感性预测不良神经功能结局,联合后敏感性进一步增高。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIMS: To assess the accuracy of electroencephalogram (EEG) and somatosensory evoked potentials (SEPs) recorded at 12 and 72 h from resuscitation for predicting six-months neurological outcome in patients who are comatose after cardiac arrest.

METHODS: Prospective multicentre prognostication study. EEG was classified according to the American Clinical Neurophysiology Society terminology. SEPs were graded according to the presence and amplitude of their cortical responses. Neurological outcome was defined as good (cerebral performance categories [CPC] 1-3) vs. poor (CPC 4-5). None of the patients underwent withdrawal of life-sustaining treatment.

RESULTS: A total of 351 patients were included, of whom 134 (38%) had good neurological outcome. At 12 h, a continuous, nearly continuous and low-voltage EEG pattern predicted good neurological outcome with 71[61-80]% sensitivity, while an isoelectric EEG and a bilaterally absent/absent-pathological amplitude (AA/AP) cortical SEP pattern predicted poor neurological outcome with 14[8-21]% and 59[50-68]% sensitivity, respectively. Specificity was 100[97-100]% for all predictors. At 72 h, both an isoelectric, suppression or burst-suppression pattern on EEG and an AA/AP SEP pattern predicted poor outcome with 100[97-100]% specificity. Their sensitivities were 63[55-70]% and 66[58-74]%, respectively. When EEG and SEPs were combined, sensitivity for poor outcome prediction increased to 79%.

CONCLUSIONS: In comatose resuscitated patients, EEG and SEPs predicted good and poor neurological outcome respectively, with 100% specificity as early as 12 h after cardiac arrest. At 72 h after arrest, unfavourable EEG and SEP patterns predicted poor neurological outcome with 100% specificity and high sensitivity, which further increased after their combination.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Scarpino M, Carrai R, Lolli F, et al. Neurophysiology for predicting good and poor neurological outcome at 12 and 72 h after cardiac arrest: The ProNeCA multicentre prospective study. Resuscitation. 2019. PMID: 31790754. doi:10.1016/j.resuscitation.2019.11.014

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。