文献速递创伤与烧伤重症综合管理与镇静镇痛

旋转血栓弹力测量预测儿童创伤输血与残疾

Rotational thromboelastometry predicts transfusion and disability in pediatric trauma.
PubMed 文献 · J Trauma Acute Care Surg · 2020-01-01
一句话结论严重创伤儿童中,EXTEM CT>84.5秒、A10<43.5mm、MCF<64.5mm与需输血相关,EXTEM CT>68.5秒与死亡或残疾相关。

该回顾性研究分析了2014至2018年一家一级创伤中心收治的90例严重创伤儿童(年龄<18岁),用ROC曲线和约登指数确定预测浓缩红细胞输注的ROTEM阈值。结果示EXTEM CT>84.5秒(p=0.049)、A10<43.5mm(p=0.025)、MCF<64.5mm(p=0.026)与需血制品输注相关;EXTEM CT>68.5秒与出院时死亡或残疾相关。作者据此提出血浆输注、纤维蛋白原替代和血小板输注的ROTEM阈值。

要点

  • 严重创伤儿童EXTEM CT>84.5秒与需血制品输注相关(p=0.049),作者据此提出血浆输注阈值。
  • EXTEM A10<43.5mm与需血制品输注相关(p=0.025),作者据此提出纤维蛋白原替代阈值。
  • EXTEM MCF<64.5mm与需血制品输注相关(p=0.026),作者据此提出血小板输注阈值。
  • EXTEM CT>68.5秒与出院时死亡或残疾相关,可用于预后评估。
  • 证据等级:预后研究Level III,治疗研究Level IV。

适用人群与场景

  • 年龄<18岁的严重创伤儿童,2014至2018年收治于一家一级创伤中心。

诊断标准与关键阈值

  • EXTEM CT>84.5秒为预测需血制品输注的阈值(p=0.049)。
  • EXTEM A10<43.5mm为预测需血制品输注的阈值(p=0.025)。
  • EXTEM MCF<64.5mm为预测需血制品输注的阈值(p=0.026)。
  • EXTEM CT>68.5秒与出院时死亡或残疾相关。

处置流程与药物剂量

  • 作者提出:EXTEM CT>84.5秒时输注血浆。
  • 作者提出:EXTEM A10<43.5mm时进行纤维蛋白原替代。
  • 作者提出:EXTEM MCF<64.5mm时输注血小板。

研究设计与关键结果

  • 回顾性分析90例严重创伤儿童,用ROC曲线和约登指数确定预测浓缩红细胞输注的ROTEM阈值。
  • EXTEM CT>84.5秒(p=0.049)、A10<43.5mm(p=0.025)、MCF<64.5mm(p=0.026)与需血制品输注相关。
  • EXTEM CT>68.5秒与出院时死亡或残疾相关。

证据类型、等级与局限

  • 研究类型:回顾性分析。
  • 证据等级:预后研究Level III;治疗研究Level IV。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者基于 findings 提出ROTEM阈值用于指导儿童创伤血制品输注:EXTEM CT>84.5秒输注血浆、A10<43.5mm进行纤维蛋白原替代、MCF<64.5mm输注血小板。
  • EXTEM CT>68.5秒可能提示出院时死亡或残疾风险,可用于预后评估。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Trauma-induced coagulopathy seen on rotational thromboelastometry (ROTEM) is associated with poor outcomes in adults; however, this relationship is poorly understood in the pediatric population. We sought to define thresholds for product-specific transfusion and evaluate the prognostic efficacy of ROTEM in injured children.

METHODS: Demographics, ROTEM, and clinical outcomes from severely injured children (age, < 18 years) admitted to a Level I trauma center between 2014 and 2018 were retrospectively analyzed. Receiver operating characteristic curves were plotted and Youden indexes were calculated against the endpoint of packed red blood cell transfusion to identify thresholds for intervention. The ROTEM parameters were compared against the clinical outcomes of mortality or disability at discharge.

RESULTS: Ninety subjects were reviewed. Increased tissue factor-triggered extrinsic pathway (EXTEM) clotting time (CT) >84.5 sec (p = 0.049), decreased EXTEM amplitude at 10 minutes (A10) <43.5 mm (p = 0.025), and decreased EXTEM maximal clot firmness (MCF) <64.5 mm (p = 0.026) were associated with need for blood product transfusion. Additionally, EXTEM CT longer than 68.5 seconds was associated with mortality or disability at discharge.

CONCLUSION: Coagulation dysregulation on thromboelastometry is associated with disability and mortality in children. Based on our findings, we propose ROTEM thresholds: plasma transfusion for EXTEM CT longer than 84.5 seconds, fibrinogen replacement for EXTEM A10 less than 43.5 mm, and platelet transfusion for EXTEM MCF less than 64.5 mm.

LEVEL OF EVIDENCE: Prognostic, Level III; Therapeutic, Level IV.

来源:J Trauma Acute Care Surg,查看原文。版权归原作者所有。

参考来源

  1. Cunningham AJ, Condron M, Schreiber MA, et al. Rotational thromboelastometry predicts transfusion and disability in pediatric trauma. J Trauma Acute Care Surg. 2020. PMID: 31688790. doi:10.1097/TA.0000000000002533

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。