高流量鼻导管与头盔无创通气在急性低氧性呼吸衰竭中的生理学比较
该生理学交叉随机研究纳入15例PaO2/FiO2<200 mmHg的低氧血症患者,分别接受头盔无创通气(PEEP≥10 cm H2O,压力支持10-15 cm H2O)和高流量鼻导管(50 L/min)。与HFNC相比,头盔无创通气提高PaO2/FiO2(中位数255 vs 138 mmHg,P=0.001),降低吸气努力(7 vs 15 cm H2O,P=0.001)、呼吸频率(24 vs 29次/分,P=0.027)、简化压力时间乘积和呼吸困难,不影响PaCO2和舒适度。总体跨肺压摆动无差异,但HFNC下吸气努力较低的患者在头盔无创通气时跨肺压摆动增加,且无创通气时较高的跨肺压摆动与后续插管需求相关。
要点
- 在PaO2/FiO2<200 mmHg的低氧血症患者中,头盔无创通气较HFNC(50 L/min)提高PaO2/FiO2中位数至255 vs 138 mmHg(P=0.001)。
- 头盔无创通气较HFNC降低吸气努力(食管压摆动中位数7 vs 15 cm H2O,P=0.001),且降低幅度与HFNC下吸气努力线性相关(r=0.84)。
- 头盔无创通气较HFNC降低呼吸频率(24 vs 29次/分,P=0.027)和呼吸困难视觉模拟评分(3 vs 8,P=0.002),PaCO2和舒适度无差异。
- 总体跨肺压摆动在两种治疗间无差异(无创通气18 vs HFNC 15 cm H2O,P=0.11),但HFNC下吸气努力较低者头盔无创通气时跨肺压摆动增加。
- 无创通气时较高的跨肺压摆动与后续插管需求相关。
适用人群与场景
- 15例低氧血症患者,PaO2/FiO2<200 mmHg,接受头盔无创通气与HFNC随机交叉顺序比较。
诊断标准与关键阈值
- 低氧血症定义为PaO2/FiO2<200 mmHg。
处置流程与药物剂量
- 头盔无创通气设置:呼气末正压≥10 cm H2O,压力支持10-15 cm H2O。
- HFNC设置:流量50 L/min。
研究设计与关键结果
- 生理学随机交叉研究,15例PaO2/FiO2<200 mmHg的低氧血症患者。
- 与HFNC相比,头盔无创通气提高PaO2/FiO2(中位数255 mmHg [四分位距140-299] vs 138 [101-172],P=0.001)。
- 头盔无创通气降低吸气努力(食管压摆动中位数7 cm H2O [4-11] vs 15 [8-19],P=0.001),降低幅度与HFNC下吸气努力线性相关(r=0.84,P<0.001)。
- 头盔无创通气降低呼吸频率(24次/分 [23-31] vs 29 [26-32],P=0.027)、简化压力时间乘积(93 cm H2O·s·min-1 [43-138] vs 200 [168-335],P=0.001)和呼吸困难视觉模拟评分(3 [2-5] vs 8 [6-9],P=0.002)。
- PaCO2(P=0.80)和舒适度(P=0.50)在两种治疗间无差异。
- 总体跨肺压摆动无差异(无创通气18 cm H2O [14-21] vs HFNC 15 [8-19],P=0.11),但HFNC下吸气努力较低的患者在头盔无创通气时跨肺压摆动增加。
- 无创通气时较高的跨肺压摆动与后续插管需求相关。
证据类型、等级与局限
- 生理学随机交叉研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在PaO2/FiO2<200 mmHg的低氧性呼吸衰竭患者中,头盔无创通气(PEEP≥10 cm H2O,压力支持10-15 cm H2O)较高流量鼻导管(50 L/min)可提高氧合、降低吸气努力和呼吸困难,但跨肺压摆动总体无差异。
- HFNC下吸气努力较低的患者在头盔无创通气时跨肺压摆动可能增加,无创通气时较高的跨肺压摆动与后续插管需求相关。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
Rationale: High-flow nasal cannula (HFNC) and helmet noninvasive ventilation (NIV) are used for the management of acute hypoxemic respiratory failure.Objectives: Physiological comparison of HFNC and helmet NIV in patients with hypoxemia.Methods: Fifteen patients with hypoxemia with PaO2/FiO2 < 200 mm Hg received helmet NIV (positive end-expiratory pressure ≥ 10 cm H2O, pressure support = 10-15 cm H2O) and HFNC (50 L/min) in randomized crossover order. Arterial blood gases, dyspnea, and comfort were recorded. Inspiratory effort was estimated by esophageal pressure (Pes) swings. Pes-simplified pressure-time product and transpulmonary pressure swings were measured.Measurements and Main Results: As compared with HFNC, helmet NIV increased PaO2/FiO2 (median [interquartile range]: 255 mm Hg [140-299] vs. 138 [101-172]; P = 0.001) and lowered inspiratory effort (7 cm H2O [4-11] vs. 15 [8-19]; P = 0.001) in all patients. Inspiratory effort reduction by NIV was linearly related to inspiratory effort during HFNC (r = 0.84; P < 0.001). Helmet NIV reduced respiratory rate (24 breaths/min [23-31] vs. 29 [26-32]; P = 0.027), Pes-simplified pressure-time product (93 cm H2O ⋅ s ⋅ min-1 [43-138] vs. 200 [168-335]; P = 0.001), and dyspnea (visual analog scale 3 [2-5] vs. 8 [6-9]; P = 0.002), without affecting PaCO2 (P = 0.80) and comfort (P = 0.50). In the overall cohort, transpulmonary pressure swings were not different between treatments (NIV = 18 cm H2O [14-21] vs. HFNC = 15 [8-19]; P = 0.11), but patients exhibiting lower inspiratory effort on HFNC experienced increases in transpulmonary pressure swings with helmet NIV. Higher transpulmonary pressure swings during NIV were associated with subsequent need for intubation.Conclusions: As compared with HFNC in hypoxemic respiratory failure, helmet NIV improves oxygenation, reduces dyspnea, inspiratory effort, and simplified pressure-time product, with similar transpulmonary pressure swings, PaCO2, and comfort.
参考来源
- Grieco DL, Menga LS, Raggi V, et al. Physiological Comparison of High-Flow Nasal Cannula and Helmet Noninvasive Ventilation in Acute Hypoxemic Respiratory Failure. Am J Respir Crit Care Med. 2020. PMID: 31687831. doi:10.1164/rccm.201904-0841OC
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。