文献速递心脑血管急症重症综合管理与镇静镇痛

视神经鞘直径与眼球横径比值对卒中患者住院期间临床预后的评估价值

[Optic nerve sheath diameter and eyeball transverse diameter as a useful tool for the clinical prognosis in patients with stroke during hospitalization].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2019-01-01
一句话结论在重症卒中患者入院当天行超声测量,视神经鞘直径>5.0 mm、视神经鞘直径/眼球横径>0.25与住院死亡显著相关,视神经鞘直径/眼球横径模型预测不良预后AUC 0.988。

该研究纳入2017年11月至2018年11月上海交通大学医学院附属上海市第一人民医院重症医学科收治的83例成人卒中(缺血性或出血性)患者,入院当天超声测量视神经鞘直径(ONSD)与眼球横径(ETD),计算ONSD/ETD比值并记录结局。住院期间45例死亡(54.2%)、38例存活出院(45.8%);死亡组与存活组的格拉斯哥昏迷评分、中线结构移位、ONSD、ONSD/ETD差异均有统计学意义(均P<0.05)。LOWESS与ROC曲线提示ONSD>5.0 mm、ONSD/ETD>0.25时死亡明显增加;校正混杂因素后ONSD模型AUC 0.978(灵敏度89%、特异度100%),ONSD/ETD模型AUC 0.988(灵敏度94%、特异度97%),ONSD/ETD稳定性优于ONSD。作者认为ONSD与ONSD/ETD可能是有前景的早期预后评估工具。

要点

  • 死亡组ONSD 5.5±0.4 mm高于存活组4.4±0.5 mm,ONSD/ETD 0.25±0.02高于存活组0.20±0.02(均P<0.05)。
  • 预测不良预后的阈值:ONSD 5.0 mm、ONSD/ETD 0.25,超过者住院死亡率明显增加。
  • 校正混杂因素后ONSD预测模型AUC 0.978、最佳预测点0.870、灵敏度89%、特异度100%。
  • ONSD/ETD预测模型AUC 0.988、最佳预测阈值0.768、预测不良预后灵敏度94%、特异度97%。
  • ONSD变异系数0.14,ONSD/ETD变异系数0.13,ONSD/ETD稳定性优于ONSD。

适用人群与场景

  • 上海交通大学医学院附属上海市第一人民医院重症医学科收治的成人卒中患者,包括缺血性卒中与出血性卒中,于入院当天行超声测量。

诊断标准与关键阈值

  • ONSD与ETD测量方法:超声测量视神经鞘直径,眼球横径为沿视神经、眼球后3 mm处视网膜到视网膜的距离,并计算ONSD/ETD比值。
  • LOWESS与ROC曲线分析提示预测卒中患者不良预后的ONSD阈值为5.0 mm、ONSD/ETD阈值为0.25。
  • ONSD预测模型最佳预测点为0.870;ONSD/ETD预测模型最佳预测阈值为0.768。

红旗征与不能漏的情况

  • ONSD>5.0 mm或ONSD/ETD>0.25的卒中患者住院死亡率明显增加。

研究设计与关键结果

  • 单中心研究纳入83例成人卒中患者,住院期间38例存活出院(45.8%)、45例死亡(54.2%)。
  • 死亡组与存活组比较:格拉斯哥昏迷评分4.7±2.8 vs. 11.0±3.2,中线结构移位5.8±5.9 mm vs. 1.3±2.6 mm,ONSD 5.5±0.4 mm vs. 4.4±0.5 mm,ONSD/ETD 0.25±0.02 vs. 0.20±0.02,差异均有统计学意义(均P<0.05)。
  • 校正混杂因素后建立的ONSD预测模型AUC 0.978,最佳预测点0.870,灵敏度89%,特异度100%。
  • ONSD/ETD预测模型AUC 0.988,最佳预测阈值0.768,预测不良临床预后的灵敏度94%,特异度97%。
  • ONSD变异系数0.14,ONSD/ETD变异系数0.13,ONSD/ETD稳定性优于ONSD。

证据类型、等级与局限

  • 证据类型:单中心队列研究(原文未报告研究类型标签,依据研究设计与结局随访描述)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为ONSD与ONSD/ETD与重症卒中患者预后显著相关,ONSD>5.0 mm、ONSD/ETD>0.25者死亡率明显增加,可能作为早期评估临床结局的有前景工具。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the prognostic value of ultrasonographic measurement of optic nerve sheath diameter (ONSD) and ONSD/eyeball transverse diameter (ETD) ratio in stroke patients during hospitalization.

METHODS: Adult patients with stroke (ischemic stroke or hemorrhagic stroke) admitted to department of critical care medicine of Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine from November 2017 to November 2018 were enrolled. On the day of admission, ONSD and ETD (retina-retina at 3 mm behind the globe along) were detected by ultrasound, the ONSD/ETD ratio was calculated, and the baseline data and outcomes were recorded. Patients were divided into survival group and death group according to their survival status. Locally weighted scatterplot smoothing (LOWESS) and the receiver operating characteristic (ROC) curve were used to calculate the thresholds of ONSD and ONSD/ETD. The correlation between ONSD, ONSD/ETD and prognosis were assessed.

RESULTS: Thirty-eight of 83 patients (45.8%) survived and were discharged from the hospital, while 45 patients died (54.2%). There were significant differences in Glasgow coma score (GCS), shifting of the middle structure, ONSD and ONSD/ETD between the death group and the survival group [GCS: 4.7±2.8 vs. 11.0±3.2, shifting of the middle structure (mm): 5.8±5.9 vs. 1.3±2.6, ONSD (mm): 5.5±0.4 vs. 4.4±0.5, ONSD/ETD: 0.25±0.02 vs. 0.20±0.02, all P < 0.05]. LOWESS and ROC curve analysis suggested thresholds of ONSD and ONSD/ETD for predicting adverse prognosis of stroke patients were 5.0 mm and 0.25, respectively. By adjusting the influence of confounding factors on prognosis, a prediction model based on ONSD was established, and the ROC curve was drawn. The area under the curve (AUC) was 0.978, the optimal predictive point of the model was 0.870, the sensitivity was 89%, and the specificity was 100%. The ONSD/ETD prediction model was also obtained, and the AUC was 0.988, the optimal prediction threshold of the model was 0.768, and the sensitivity for predicting adverse clinical prognosis was 94%, and the specificity was 97%. The stability of ONSD/ETD was better than that of ONSD. ONSD coefficient of variation was 0.14, and ONSD/ETD coefficient of variation was 0.13.

CONCLUSIONS: ONSD and ONSD/ETD were significantly correlated with the prognosis of critical patients with stroke. The mortality increased significantly in patients with an ONSD greater than 5.0 mm and ONSD/ETD greater than 0.25. ONSD and ONSD/ETD may be promising tools for early assessment of clinical outcomes in these patients.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Zhao L, Huang Q, Huang P, et al. [Optic nerve sheath diameter and eyeball transverse diameter as a useful tool for the clinical prognosis in patients with stroke during hospitalization]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2019. PMID: 31771722. doi:10.3760/cma.j.issn.2095-4352.2019.10.012

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。