肝素结合蛋白在成人脓毒症诊断中的价值:一项Meta分析
该Meta分析检索PubMed、Embase、Cochrane图书馆、万方、中国知网和维普至2019年7月的文献,纳入10项研究共1884例成人患者,评估血浆肝素结合蛋白(HBP)诊断脓毒症的价值。所有研究均用酶联免疫吸附法(ELISA)检测HBP。汇总敏感度0.80(95%CI 0.77-0.83)、特异度0.80(95%CI 0.78-0.82)、阳性似然比3.96(95%CI 2.45-6.41)、阴性似然比0.28(95%CI 0.20-0.39)、诊断比值比14.63(95%CI 6.83-31.30),汇总AUC 0.86。亚组分析未发现方法学协变量影响诊断准确性,仍存在无法解释的异质性;敏感性分析结果较稳定可靠,Deek漏斗图提示发表偏倚小。作者认为HBP对成人脓毒症诊断有较好价值,但需大型多中心研究进一步证实。
要点
- 汇总10项研究1884例成人患者,血浆HBP诊断脓毒症的汇总敏感度0.80(95%CI 0.77-0.83)、特异度0.80(95%CI 0.78-0.82)。
- 汇总阳性似然比3.96(95%CI 2.45-6.41)、阴性似然比0.28(95%CI 0.20-0.39)、诊断比值比14.63(95%CI 6.83-31.30)。
- 汇总AUC 0.86,所有研究均采用ELISA法检测血浆HBP。
- 研究间存在明显异质性,采用随机效应模型;按疾病严重程度、诊断标准和地区亚组分析未发现方法学协变量影响诊断准确性,仍有无法解释的异质性。
- 剔除单项研究的敏感性分析未发现离群研究,结果较稳定可靠;Deek漏斗图提示发表偏倚小。
适用人群与场景
- 成人脓毒症诊断场景,纳入关于HBP诊断成人脓毒症的中英文文献。
研究设计与关键结果
- 研究类型为Meta分析,共纳入10项研究、1884例患者;所有研究均用ELISA法检测血浆HBP。
- 汇总敏感度0.80(95%CI 0.77-0.83)、特异度0.80(95%CI 0.78-0.82)、阳性似然比3.96(95%CI 2.45-6.41)、阴性似然比0.28(95%CI 0.20-0.39)、诊断比值比14.63(95%CI 6.83-31.30)。
- 汇总AUC 0.86,Cochran-Q为0.79。
- 研究间存在明显异质性,采用随机效应模型;按疾病严重程度、诊断标准和地区行亚组分析,未发现方法学协变量影响HBP诊断准确性,仍存在无法解释的异质性。
- 剔除单项研究的敏感性分析未发现离群研究,结果较稳定可靠;Deek漏斗图提示发表偏倚小。
证据类型、等级与局限
- 证据类型为Meta分析,文献质量用QUADAS-2工具评估,质量相对中等。
- 研究间存在明显异质性,采用随机效应模型;亚组分析未发现方法学协变量影响诊断准确性,仍有无法解释的异质性。
- 局限:作者指出需大型多中心研究进一步证实。
对床旁实践的改变
- 作者认为HBP对成人脓毒症诊断有较好价值,但需大型多中心研究进一步证实。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the application of heparin-binding protein (HBP) in diagnosis of sepsis in adult patients.
METHODS: An extensive search for the Chinese and English literatures from the PubMed, Embase, the Cochrane Library, Wanfang data, CNKI and VIP up to July 2019 was performed. The articles regarding HBP for the diagnosing of sepsis in adult patients were enrolled. Two researchers independently extracted related literature. The quality of the studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Meta-Disc 1.4 and STATA 12.0 were used for Meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were calculated. Summary receiver operating characteristic (SROC) curves and area under the curve (AUC) were used to evaluate the diagnostic performance of HBP for sepsis. Deek funnel plot was used to detect publication bias.
RESULTS: A total of 10 studies with 1 884 patients were included in this Meta-analysis. The quality of the literature was relatively moderate. HBP in plasma were detected by enzyme linked immunosorbent assay (ELISA) in all studies. The studies showed substantial heterogeneity, and random effect model was used for Meta-analysis. The pooled sensitivity, specificity, PLR, NLR, and DOR were 0.80 [95% confidence interval (95%CI) was 0.77-0.83], 0.80 (95%CI was 0.78-0.82), 3.96 (95%CI was 2.45-6.41), 0.28 (95%CI was 0.20-0.39) and 14.63 (95%CI was 6.83-31.30) respectively. The pooled AUC was 0.86 and the Cochran-Q was 0.79. To explore the potential sources of heterogeneity, subgroup analyses were performed based on the severity of the disease, diagnostic criteria and region. However, the results indicated that no methodological covariates affected the diagnostic accuracy of HBP, indicating that there was still unexplained heterogeneity. In addition, the sensitivity analysis by removing individual studies were performed. No outlier study was identified and the results were relatively stable and reliable. Deek funnel plot showed little publication bias.
CONCLUSIONS: There is preferable value of HBP for diagnosis of sepsis in adult patients. However, it needs to be further confirmed by large multicenter studies.
参考来源
- Chen M, Yuan J, Yang Z, et al. [Value of heparin-binding protein in diagnosis of sepsis in adult patients: a Meta-analysis]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2019. PMID: 31771719. doi:10.3760/cma.j.issn.2095-4352.2019.10.009
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。