文献速递重症综合管理与镇静镇痛

白细胞滤器过滤后剩余血回输对体外循环术后细胞免疫功能的影响

[Effects of reinfusion of the remaining blood filtered by leukocyte depletion filter on postoperative cellar immune function after cardiopulmonary bypass].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2019-01-01
一句话结论心脏瓣膜置换体外循环术后,白细胞滤器过滤剩余血回输可降低炎症因子水平、缩短机械通气与ICU停留时间,且不增加感染发生率。

该研究纳入2018年1月至6月在海口市人民医院麻醉科行择期体外循环心脏瓣膜置换术的40例患者,随机分为实验组和对照组各20例。实验组回输经白细胞滤器过滤后储存于无菌采血袋的剩余机血,对照组回输未经滤器过滤的剩余机血。结果显示两组T淋巴细胞亚群CD3+、CD4+、CD8+、NK细胞及CD4+/CD8+比值各时间点无统计学差异;实验组回输后第3天起血浆TNF-α、IL-6、IL-8低于对照组,且机械通气时间和ICU停留时间显著缩短,住院时间和伤口及肺部感染发生率无统计学差异。结论认为白细胞滤器过滤剩余血回输可抑制炎症反应、不影响细胞免疫功能、不增加感染发生率。

要点

  • 体外循环心脏瓣膜置换术后回输白细胞滤器过滤的剩余血,不增加伤口感染(25.0% vs 15.0%)和肺部感染(5.0% vs 15.0%)发生率,两组差异无统计学意义。
  • 过滤组回输后第3天血浆TNF-α(28.49±4.66 vs 33.82±4.30 ng/L)、IL-6(25.98±4.51 vs 31.38±5.42 ng/L)、IL-8(38.98±4.67 vs 45.76±5.33 ng/L)均低于对照组,差异有统计学意义。
  • 过滤组机械通气时间(8.07±1.30 vs 9.16±1.52小时)和ICU停留时间(28.22±2.78 vs 31.25±3.18小时)较对照组显著缩短。
  • 两组CD3+、CD4+、CD8+、NK细胞及CD4+/CD8+比值各时间点比较均无统计学差异,过滤回输不影响细胞免疫功能。
  • 两组剩余血量无统计学差异(959.00±116.84 vs 971.50±115.68 mL),住院时间无统计学差异(20.65±2.76 vs 22.45±3.22天)。

适用人群与场景

  • 2018年1月至6月在海口市人民医院麻醉科行择期体外循环心脏瓣膜置换术的患者40例,男22例、女18例,年龄(47.88±12.29)岁,ASA II级25例、III级15例。

处置流程与药物剂量

  • 实验组:将剩余机血经白细胞滤器过滤后储存于无菌采血袋,体外循环结束后回输。
  • 对照组:将剩余机血储存于无菌采血袋,未经白细胞滤器过滤,体外循环结束后回输。

研究设计与关键结果

  • 研究类型为随机对照试验,采用随机数字表法分组,样本量40例,实验组和对照组各20例。
  • 两组剩余血量无统计学差异(mL:959.00±116.84 vs 971.50±115.68,P>0.05)。
  • 与T1相比,两组CD3+、CD4+、CD8+、NK细胞及血浆IL-2水平从T2起显著下降,CD4+/CD8+比值从T3起显著下降;两组间各时间点CD3+、CD4+、CD8+、NK细胞、CD4+/CD8+比值及血浆IL-2水平均无统计学差异。
  • 与T1相比,两组血浆TNF-α、IL-6、IL-8水平在T2显著升高后逐渐下降;实验组从T3起TNF-α(ng/L:28.49±4.66 vs 33.82±4.30)、IL-6(ng/L:25.98±4.51 vs 31.38±5.42)、IL-8(ng/L:38.98±4.67 vs 45.76±5.33)低于对照组,均P<0.05,至T5恢复至T1水平。
  • 与对照组相比,实验组机械通气时间(小时:8.07±1.30 vs 9.16±1.52)和ICU停留时间(小时:28.22±2.78 vs 31.25±3.18)显著缩短,均P<0.05。
  • 两组住院时间(天:20.65±2.76 vs 22.45±3.22)、伤口感染发生率(25.0% vs 15.0%)和肺部感染发生率(5.0% vs 15.0%)无统计学差异,均P>0.05。

证据类型、等级与局限

  • 证据类型为随机对照试验,样本量40例,实验组和对照组各20例。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,白细胞滤器过滤剩余血回输可抑制炎症反应、不影响细胞免疫功能、不增加感染发生率。
  • 该研究提示,体外循环心脏瓣膜置换术后回输经白细胞滤器过滤的剩余血,与未过滤回输相比,可能降低术后炎症因子水平并缩短机械通气时间和ICU停留时间。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate effects of reinfusion of the remaining blood filtered by leukocyte depletion filter on postoperative cellular immune function after cardiopulmonary bypass (CPB).

METHODS: Forty patients who underwent selective cardiac valve replacement surgery with CPB in department of anesthesiology of Haikou Municipal Hospital from January to June in 2018 were enrolled. All the patients were divided into the control group and experimental group according to the random number table method, with 20 patients in each group. In the experimental group, patients received residual pump blood transfusion which had been filtered by leukocyte depletion filter and stored in sterile blood collection bags. In the control group, patients received residual pump blood transfusion which was stored in sterile blood collection bags without being filtered. The remaining blood was reinfused after CPB in two groups. Blood samples were taken before CPB (T1), 2 hours following CPB (T2), and 1, 3, 5 days after reinfusion of the remaining blood (T3, T4, T5), the levels of T lymphocyte subsets CD3+, CD4+, CD8+ and natural killer cells (NK cells) were detected by flow cytometer, and CD4+/CD8+ ratio was calculated. The levels of plasma tumor necrosis factor-α (TNF-α), interleukins (IL-2, IL-6, IL-8) were measured by enzyme linked immunosorbent essay (ELISA). The duration of mechanical ventilation, the length of intensive care unit (ICU) stay, the length of hospital stay, and incidence of wound and pulmonary infection after surgery were compared between two groups.

RESULTS: Among 40 patients, there were 22 males and 18 females; with an age of (47.88±12.29) years old; and with 25 cases of American Society of Anesthesiologists (ASA) physical status II, and 15 cases of ASA III. There was no statistical difference in the volume of the remaining blood between the two groups (mL: 959.00±116.84 vs. 971.50±115.68, P > 0.05). Compared with T1, the levels of T lymphocyte subsets CD3+, CD4+, CD8+, NK cells and plasma levels of IL-2 were significantly decreased from T2, the CD4+/CD8+ ratio was significantly decreased from T3 in two groups, but there was no statistical difference in CD3+, CD4+, CD8+, NK cells, CD4+/CD8+ ratio or plasma level of IL-2 at each time between the two groups. Compared with T1, the plasma levels of TNF-α, IL-6 and IL-8 were significantly increased at T2 in two groups and then decreased gradually. The plasma levels of TNF-α, IL-6 and IL-8 from T3 in experimental group were lower than those in control group [TNF-α (ng/L): 28.49±4.66 vs. 33.82±4.30, IL-6 (ng/L): 25.98±4.51 vs. 31.38±5.42, IL-8 (ng/L): 38.98±4.67 vs. 45.76±5.33, all P < 0.05], they restored to the level of T1 at T5. In addition, compared with control group, the duration of mechanical ventilation, the length of ICU stay in experimental group were significantly decreased (hours: 8.07±1.30 vs. 9.16±1.52, 28.22±2.78 vs. 31.25±3.18, both P < 0.05), and there was no statistical difference in the length of hospital stay (days: 20.65±2.76 vs. 22.45±3.22), incidence of wound and pulmonary infection (25.0% vs. 15.0%, 5.0% vs. 15.0%) between the two groups (all P > 0.05).

CONCLUSIONS: Reinfusion of the remaining blood filtered by leukocyte depletion filtercan inhibit inflammatory responses and don't affect the function of cellular immunity, and don't increase the incidence of infection.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Luo L, Wang D, Chen M, et al. [Effects of reinfusion of the remaining blood filtered by leukocyte depletion filter on postoperative cellar immune function after cardiopulmonary bypass]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2019. PMID: 31537225. doi:10.3760/cma.j.issn.2095-4352.2019.08.015

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。