文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

快速反应小组处理血流动力学不稳定患者时的无创连续血流动力学监测及干预反应

Non-invasive continuous haemodynamic monitoring and response to intervention in haemodynamically unstable patients during rapid response team review.
PubMed 文献 · Resuscitation · 2019-08-22
一句话结论在快速反应小组处理血流动力学不稳定患者时,ClearSight™可在20分钟内连续无创记录心脏指数(50例中47例成功,94%),但心率、心脏指数、每搏量指数和全身血管阻力指数均无显著变化。

本研究为前瞻性观察研究,纳入由快速反应小组因心动过速和(或)低血压管理的成年患者,用ClearSight™无创连续监测基线及处理过程中的心脏指数(CI)和平均动脉压(MAP)。50例中47例(94%)成功记录CI。因低血压(而非心动过速)触发快速反应小组者,基线心率低45.4次/分、MAP低16.1 mmHg、CI低1.0 L/min/m2。心动过速组MAP自83.2 mmHg升至87.1 mmHg(+3.9 mmHg,p=0.0066),15–20分钟时段为85.5 mmHg(+2.3 mmHg,p=0.0061);接受液体负荷治疗(FBT)者MAP自70.1 mmHg升至73.5 mmHg(+3.4 mmHg,p=0.0036),15–20分钟时段为74.3 mmHg(+4.2 mmHg,p=0.0037)。但各组在20分钟整体或5分钟时段内,平均心率、CI、每搏量指数和全身血管阻力指数均无统计学显著变化。

要点

  • 50例中47例(94%)用ClearSight™成功连续无创记录CI,监测可持续20分钟。
  • 低血压触发快速反应小组者基线心率低45.4次/分、MAP低16.1 mmHg、CI低1.0 L/min/m2(均较心动过速触发者)。
  • 心动过速组MAP总体自83.2 mmHg升至87.1 mmHg(+3.9 mmHg,p=0.0066),15–20分钟时段为85.5 mmHg(+2.3 mmHg,p=0.0061)。
  • FBT组MAP总体自70.1 mmHg升至73.5 mmHg(+3.4 mmHg,p=0.0036),15–20分钟时段为74.3 mmHg(+4.2 mmHg,p=0.0037)。
  • 各组平均心率、CI、每搏量指数和全身血管阻力指数在20分钟整体及各5分钟时段均无统计学显著变化。

适用人群与场景

  • 由快速反应小组管理的成年患者,因心动过速或低血压或两者兼有而触发快速反应小组。

研究设计与关键结果

  • 前瞻性观察研究,纳入快速反应小组因心动过速或低血压或两者兼有管理的成年患者,用ClearSight™无创连续监测基线及处理中的CI和MAP。
  • 50例中47例(94%)成功记录CI。
  • 低血压触发者较心动过速触发者基线心率低45.4次/分(p=<0.0001)、MAP低16.1 mmHg(p=0.0007)、CI低1.0 L/min/m2(p=0.0025)。
  • 心动过速组MAP总体自83.2 mmHg升至87.1 mmHg(+3.9 mmHg,p=0.0066),15–20分钟时段自基线升至85.5 mmHg(+2.3 mmHg,p=0.0061)。
  • FBT组MAP总体自70.1 mmHg升至73.5 mmHg(+3.4 mmHg,p=0.0036),15–20分钟时段自基线升至74.3 mmHg(+4.2 mmHg,p=0.0037)。
  • 各组在20分钟整体或各5分钟时段内,平均心率、CI、每搏量指数、全身血管阻力指数均无统计学显著变化。

证据类型、等级与局限

  • 证据类型:前瞻性观察研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 原文结论认为,对血流动力学不稳定的快速反应小组管理患者,连续无创血流动力学监测持续20分钟是可行的;低血压触发者基线心率、MAP和CI更低;心动过速组和FBT组MAP在15–20分钟时段及总体上出现统计学显著但幅度较小的升高。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: During rapid response team (RRT) management of haemodynamic instability (HI), continuous non-invasive haemodynamic monitoring may provide supplemental physiological information.

OBJECTIVES: To continuously and non-invasively obtain the cardiac index (CI) and mean arterial pressure (MAP) in patients with HI at baseline and during RRT management using the ClearSight™ device.

METHODS: We performed a prospective observational study in adult patients managed by the RRT for tachycardia or hypotension or both. We assessed changes from baseline in heart rate (HR), MAP, CI, stroke volume index (SVI) and systemic vascular resistance index (SVRI) (i) at 5-minutely intervals up to 20 min, and (ii) over the entire 20-min period. We analysed patients by RRT trigger (tachycardia/hypotension) and intervention (fluid bolus therapy [FBT]/ no FBT).

RESULTS: We successfully recorded the CI in 47 of 50 (94%) patients. RRT reviews triggered by hypotension rather than tachycardia had a lower baseline HR (-45.4 bpm, p = <0.0001), MAP (-16.1 mmHg, p = 0.0007) and CI (1.0 L/min/m2, p = 0.0025). Compared to baseline, in the tachycardia group, there was a small increase in MAP overall and at the 15-20 min time-block from 83.2 mmHg to 87.1 mmHg (+3.9 mmHg, p = 0.0066) and 85.5 mmHg (+2.3 mmHg, p = 0.0061), respectively. In those who received FBT, there was a statistically significant increase in MAP overall and at the 15-20 min time-block compared to baseline, from 70.1 mmHg to 73.5 mmHg (+3.4 mmHg, p = 0.0036) and 74.3 mmHg (+4.2 mmHg, p = 0.0037), respectively. However, there were no statistically significant changes in mean HR, CI, SVI, or SVRI when comparing baseline to the entire 20-min period or 5-min time-blocks within any group.

CONCLUSIONS: Continuous non-invasive measurement of haemodynamics during RRT management for HI was possible for 20 min. Patients with hypotension rather than tachycardia had lower baseline HR, MAP and CI values. There was a statistically significant but small increase in MAP at the 15-20 min time-block and overall, for both the tachycardia and FBT groups.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Eyeington CT, Lloyd-Donald P, Chan MJ, et al. Non-invasive continuous haemodynamic monitoring and response to intervention in haemodynamically unstable patients during rapid response team review. Resuscitation. 2019. PMID: 31446156. doi:10.1016/j.resuscitation.2019.08.025

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。