文献速递呼吸衰竭与机械通气儿科与产科急症

电子心脏(ECG)监测对产房复苏和新生儿结局的影响

Impact of electronic cardiac (ECG) monitoring on delivery room resuscitation and neonatal outcomes.
PubMed 文献 · Resuscitation · 2019-08-05
一句话结论产房实施ECG监测与气管插管减少、胸外按压增加相关,死亡率无差异。

该观察性队列研究比较了产房实施ECG监测前(2015年回顾性队列)与后(2017年前瞻性队列)接受正压通气的新生儿。共632例接受正压通气的新生儿,ECG监测组369例,无ECG监测组263例。ECG监测组产房气管插管率显著降低(36% vs 48%,P<.005),5分钟Apgar评分更高(7[5-8] vs 6[5-8],P<.05)。死亡率无差异(8% vs 9%),但ECG监测组接受胸外按压的校正比值比为3.6(95%CI 1.4-9.5)。

要点

  • 产房ECG监测与气管插管率降低相关:ECG组36% vs 无ECG组48%(P<.005)。
  • 产房ECG监测与5分钟Apgar评分更高相关:7[5-8] vs 6[5-8](P<.05)。
  • ECG监测组接受胸外按压的校正比值比为3.6(95%CI 1.4-9.5)。
  • 两组死亡率无差异:ECG组8% vs 无ECG组9%。

适用人群与场景

  • 产房内接受正压通气的新生儿。

研究设计与关键结果

  • 观察性队列研究,比较产房实施ECG监测前(2015年回顾性队列)与后(2017年前瞻性队列)接受正压通气的新生儿,共632例,ECG监测组369例,无ECG监测组263例。
  • ECG监测组产房气管插管率显著低于无ECG监测组(36% vs 48%,P<.005)。
  • ECG监测组5分钟Apgar评分高于无ECG监测组(7[5-8] vs 6[5-8],P<.05)。
  • 两组死亡率无差异(ECG组8% vs 无ECG组9%)。
  • ECG监测组接受胸外按压的校正比值比为3.6(95%CI 1.4-9.5)。

证据类型、等级与局限

  • 证据类型:观察性队列研究(前后对照)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 产房实施ECG监测与气管插管减少和胸外按压增加相关,死亡率无差异。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM: In 2016, the neonatal resuscitation guidelines suggested electronic cardiac (ECG) monitoring to assess heart rate for an infant receiving positive pressure ventilation immediately after birth. Our aim was to study the impact of ECG monitoring on delivery room resuscitation interventions and neonatal outcomes.

METHODS: Observational cohort study compared maternal, perinatal and infant characteristics, before (retrospective cohort, calendar year 2015) and after (prospective cohort, calendar year 2017) implementation of ECG monitoring in the delivery room. Association of ECG monitoring with delivery room resuscitation practice interventions and neonatal outcomes was assessed using unadjusted and adjusted multivariable regression analyses.

RESULTS: Of 632 newly born infants who received positive pressure ventilation in the delivery room, ECG monitoring was performed in 369 (the prospective cohort) compared with no ECG monitoring in 263 (the retrospective cohort). Compared to neonates in the retrospective cohort, neonates with ECG monitoring had a significantly lower endotracheal intubation rate (36% vs 48%, P < .005) in the delivery room and higher 5-min Apgar scores (7 [5-8] vs 6 [5-8], P < .05). There was no difference in mortality (31 [8%] vs 23 [9%]), but infants who received ECG monitoring had increased odds of receiving chest compressions with an adjusted odds ratio of 3.6 (95% confidence interval: 1.4-9.5).

CONCLUSION: Introduction of ECG monitoring in the delivery room was associated with fewer endotracheal intubations, and an increase use of chest compressions with no difference in mortality.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Shah BA, Wlodaver AG, Escobedo MB, et al. Impact of electronic cardiac (ECG) monitoring on delivery room resuscitation and neonatal outcomes. Resuscitation. 2019. PMID: 31394156. doi:10.1016/j.resuscitation.2019.07.031

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。