急诊创伤剖腹术中呼气末二氧化碳低估血浆二氧化碳导致通气不足与复苏不当:西部创伤协会多中心研究
这项多中心试验分析急诊创伤剖腹术中呼气末二氧化碳(ETCO2)与血浆二氧化碳(pCO2)的相关性,共纳入256例患者、587对匹配值。两者相关性极差(R=0.04),在酸中毒或高碳酸血症患者中更差;45%患者ETCO2与pCO2差值>10 mm Hg。pH<7.30可预测差值>10 mm Hg,而差值>10 mm Hg可独立预测死亡率。作者认为依赖不一致的ETCO2值可能导致约40%患者入手术室时存在酸中毒和高碳酸血症,建议早期行动脉血气分析并考虑更低的早期ETCO2目标。
要点
- 急诊创伤剖腹术中ETCO2与pCO2相关性极差(R=0.04),不能可靠反映通气状态。
- 45%患者ETCO2与pCO2差值>10 mm Hg,差值>10 mm Hg可独立预测死亡率。
- 40.2%患者入手术室时pH<7.30且pCO2>45 mm Hg,依赖ETCO2可能贡献于通气不足。
- pH<7.30可预测ETCO2与pCO2差值>10 mm Hg,提示酸中毒患者更易出现不一致。
- 作者建议早期行动脉血气分析,并考虑更低的早期ETCO2目标。
适用人群与场景
- 接受急诊剖腹手术的创伤患者,处于失血性休克复苏阶段。
诊断标准与关键阈值
- 酸中毒定义为pH<7.30;高碳酸血症定义为pCO2>45 mm Hg。
- ETCO2与pCO2差值>10 mm Hg为显著不一致。
处置流程与药物剂量
- 作者建议早期行动脉血气分析以获取pCO2。
- 作者建议考虑更低的早期ETCO2目标。
红旗征与不能漏的情况
- ETCO2与pCO2差值>10 mm Hg,与死亡率独立相关。
- pH<7.30提示ETCO2与pCO2差值可能>10 mm Hg。
研究设计与关键结果
- 多中心试验纳入256例患者,获得587对ETCO2与pCO2匹配值。
- ETCO2与pCO2相关性极差,R=0.04。
- 40.2%患者入手术室时pH<7.30且pCO2>45 mm Hg。
- 在酸中毒或高碳酸血症患者中,ETCO2与pCO2相关性更差。
- 45%患者ETCO2与pCO2差值>10 mm Hg。
- pH<7.30可预测ETCO2与pCO2差值>10 mm Hg。
- 差值>10 mm Hg可独立预测死亡率。
证据类型、等级与局限
- 证据类型:多中心试验,治疗性证据等级IV级。
对床旁实践的改变
- 在急诊创伤剖腹术中不应仅依赖ETCO2评估通气,应早期行动脉血气分析。
- 作者认为可考虑更低的早期ETCO2目标以降低通气不足风险。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: End-tidal carbon dioxide (ETCO2) is routinely used during elective surgery to monitor ventilation. The role of ETCO2 monitoring in emergent trauma operations is poorly understood. We hypothesized that ETCO2 values underestimate plasma carbon dioxide (pCO2) values during resuscitation for hemorrhagic shock.
METHODS: Multicenter trial was performed analyzing the correlation between ETCO2 and pCO2 levels.
RESULTS: Two hundred fifty-six patients resulted in 587 matched pairs of ETCO2 and pCO2. Correlation between these two values was very poor with an R of 0.04. 40.2% of patients presented to the operating room acidotic and hypercarbic with a pH less than 7.30 and a pCO2 greater than 45 mm Hg. Correlation was worse in patients that were either acidotic or hypercarbic. Forty-five percent of patients have a difference greater than 10 mm Hg between ETCO2 and pCO2. A pH less than 7.30 was predictive of an ETCO2 to pCO2 difference greater than 10 mm Hg. A difference greater than 10 mm Hg was predictive of mortality independent of confounders.
CONCLUSION: Nearly one half (45%) of patients were found to have an ETCO2 level greater than 10 mm Hg discordant from their PCO2 level. Reliance on the discordant values may have contributed to the 40% of patients in the operating room that were both acidotic and hypercarbic. Early blood gas analysis is warranted, and a lower early goal of ETCO2 should be considered.
LEVEL OF EVIDENCE: Therapeutic, level IV.
参考来源
- Campion EM, Robinson CK, Brant N, et al. End-tidal carbon dioxide underestimates plasma carbon dioxide during emergent trauma laparotomy leading to hypoventilation and misguided resuscitation: A Western Trauma Association Multicenter Study. J Trauma Acute Care Surg. 2019. PMID: 31389913. doi:10.1097/TA.0000000000002469
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。