文献速递重症综合管理与镇静镇痛消化、代谢与肾脏急症

氧化应激因子与脓毒症患者预后的相关性

[Correlation between oxidative stress factors and prognosis of patients with sepsis].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2019-01-01
一句话结论脓毒症患者血浆MDA、NO升高且与肾损伤及28天死亡正相关,SOD降低与死亡负相关,三者可作为独立生物标志物预测28天死亡。

该病例对照研究纳入中山大学附属第一医院外科ICU 2016年3—12月收治的25例脓毒症患者与同期15例非脓毒症对照,检测血浆SOD、MDA、NO等氧化应激指标及器官损伤指标。脓毒症组ICU住院时间、AST、BUN、CRP、PCT、MDA、NO均显著高于对照组,而性别、年龄、APACHEⅡ评分、总住院时间、28天病死率、ALT、SCr、WBC、SOD两组无显著差异。脓毒症组内MDA、NO与SCr正相关,SOD与28天病死率负相关,MDA、NO与28天病死率正相关。ROC分析显示SOD、MDA、NO对28天病死率有较好独立预测价值,AUC分别为0.816±0.087、0.904±0.078、0.912±0.071。

要点

  • 脓毒症组血浆MDA 488.31±76.68 ng/L、NO 5.08±0.89 ng/L,均显著高于非脓毒症组的399.30±50.23 ng/L和4.42±0.88 ng/L(均P<0.05)。
  • 脓毒症组28天病死率与SOD活性呈负相关(r=-0.468,P<0.05),与MDA、NO呈正相关(r=0.598、0.611,均P<0.01)。
  • MDA、NO与SCr正相关(r=0.426、0.431,均P<0.05),MDA与NO之间正相关(r=0.990,P<0.01)。
  • ROC分析:SOD预测28天病死率AUC 0.816±0.087,最佳截断值40.76%(敏感度68.4%、特异度100%)。
  • MDA预测28天病死率AUC 0.904±0.078,最佳截断值487.93 ng/L(敏感度83.3%、特异度89.5%);NO AUC 0.912±0.071,最佳截断值5.31 ng/L(敏感度83.3%、特异度89.5%)。

适用人群与场景

  • 2016年3—12月收入中山大学附属第一医院外科ICU、诊断为脓毒症的患者25例为研究对象;同期收入该外科ICU的非脓毒症患者15例为对照。

研究设计与关键结果

  • 研究类型:病例对照研究;样本量:脓毒症组25例、非脓毒症对照组15例;人群:外科ICU患者;检测血浆SOD、MDA、NO及ALT、AST、SCr、BUN、CRP、PCT、WBC,记录APACHEⅡ评分、ICU住院时间、总住院时间及28天病死率。
  • 脓毒症组ICU住院时间较非脓毒症组长[天:7.0(5.5,11.0)vs. 4.0(1.0,11.0),P<0.05];AST、BUN、CRP、PCT、MDA、NO均显著高于非脓毒症组(均P<0.05)。
  • 两组性别、年龄、APACHEⅡ评分、总住院时间、28天病死率、ALT、SCr、WBC及血浆SOD活性差异均无显著差异。
  • 脓毒症组内相关性分析:MDA、NO与SCr正相关(r分别为0.426、0.431,均P<0.05),MDA与NO正相关(r=0.990,P<0.01);SOD与28天病死率负相关(r=-0.468,P<0.05),MDA、NO与28天病死率正相关(r分别为0.598、0.611,均P<0.01)。
  • ROC曲线:SOD预测28天病死率AUC 0.816±0.087,最佳截断值40.76%(敏感度68.4%、特异度100%);MDA AUC 0.904±0.078,最佳截断值487.93 ng/L(敏感度83.3%、特异度89.5%);NO AUC 0.912±0.071,最佳截断值5.31 ng/L(敏感度83.3%、特异度89.5%)。

证据类型、等级与局限

  • 证据类型:病例对照研究;原文未报告证据等级。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为血浆SOD、MDA、NO水平可作为独立生物标志物预测脓毒症患者的28天病死率。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the relationship between plasma oxidative stress factors levels and organ damage parameters as well as prognosis in patients with sepsis.

METHODS: A case-control study was conducted. Twenty-five patients admitted to surgical intensive care unit (ICU) of the First Affiliated Hospital of Sun Yat-sen University from March to December in 2016 and diagnosed as sepsis were enrolled as study subjects. Another 15 patients without sepsis admitted to surgical ICU in the same period were enrolled as controls. General demographic data, main diagnoses, acute physiology and chronic health evaluation II (APACHE II) score within 24 hours, clinical laboratory indicators [alanine aminotransferase (ALT), aspartate transaminase (AST), serum creatinine (SCr), blood urea nitrogen (BUN), C-reactive protein (CRP), procalcitonin (PCT), white blood count (WBC)] and oxidative stress indicators [superoxide dismutase (SOD), malondialdehyde (MDA) and nitric oxide (NO)] as well as length of ICU stay, total hospital stay and 28-day mortality were recorded. Spearman or Pearson correlation method was used to analyze the correlation between oxidative stress indicators and organ damage indicators as well as prognosis in patients with sepsis. Receiver operator characteristic (ROC) curve was plotted to evaluate the predictive value of oxidative stress indicators for 28-day mortality in patients with sepsis.

RESULTS: The length of ICU stay in sepsis group was significantly longer than that in non-sepsis group [days: 7.0 (5.5, 11.0) vs. 4.0 (1.0, 11.0), P < 0.05], and AST, BUN, CRP, PCT, plasma MDA and NO levels were significantly higher than those in non-sepsis group [AST (U/L): 50.76±19.53 vs. 28.53±14.02, BUN (mmol/L): 9.99±5.26 vs. 6.97±4.32, CRP (mg/L): 109.28±42.79 vs. 60.33±46.68, PCT (μg/L): 5.4 (0.3, 24.0) vs. 0.6 (0.1, 1.5), MDA (ng/L): 488.31±76.68 vs. 399.30±50.23, NO (ng/L): 5.08±0.89 vs. 4.42±0.88, all P < 0.05]. There was no significant difference in gender, age, APACHE II score, total hospital stay, 28-day mortality, ALT, SCr, WBC or plasma SOD activity between the two groups. The correlation analysis between oxidative stress parameters and organ damage parameters as well as prognosis in patients with sepsis showed that MDA and NO were positively correlated with SCr (r value was 0.426 and 0.431, respectively, both P < 0.05), and there was a positive correlation between MDA and NO (r = 0.990, P < 0.01); plasma SOD activity was negatively correlated with 28-day mortality (r = -0.468, P < 0.05), while MDA and NO levels were positively correlated with 28-day mortality (r value was 0.598 and 0.611, respectively, both P < 0.01). ROC curve analysis showed that plasma SOD, MDA and NO levels had a good independent predictive effect on 28-day mortality, the area under ROC curve (AUC) was 0.816±0.087, 0.904±0.078 and 0.912±0.071, and the best cut-off value was 40.76% (sensitivity 68.4%, specificity 100%), 487.93 ng/L (sensitivity 83.3%, specificity 89.5%) and 5.31 ng/L (sensitivity 83.3%, specificity 89.5%), respectively.

CONCLUSIONS: The plasma levels of oxidative stress factors in patients with sepsis are significantly increased, which is closely related to organ damage and poor prognosis. The plasma SOD, MDA and NO levels can be used as independent bio-marker to predict the 28-day mortality of patients with sepsis.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Qiu C, Wu J, Pei F, et al. [Correlation between oxidative stress factors and prognosis of patients with sepsis]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2019. PMID: 31441408. doi:10.3760/cma.j.issn.2095-4352.2019.07.010

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。