文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

平衡晶体液与生理盐水在脓毒症中的应用:SMART临床试验的二次分析

Balanced Crystalloids versus Saline in Sepsis. A Secondary Analysis of the SMART Clinical Trial.
PubMed 文献 · Am J Respir Crit Care Med · 2019-01-01
一句话结论在SMART试验的脓毒症患者二次分析中,使用平衡晶体液与30天院内死亡率低于使用生理盐水相关(aOR 0.74)。

该研究为SMART(等渗溶液与主要不良肾脏事件试验)的二次分析,纳入收入内科ICU且带有脓毒症ICD-10-CM编码的患者1641例,采用多变量回归控制混杂因素,比较平衡晶体液与生理盐水对30天院内死亡率的影响。结果:平衡晶体液组30天院内死亡率为26.3%(217例),生理盐水组为31.2%(255例),校正后OR 0.74(95%CI 0.59-0.93;P=0.01);平衡晶体液组30天内主要不良肾脏事件发生率更低(35.4% vs 40.1%;aOR 0.78;95%CI 0.63-0.97),无血管活性药物天数更多(20±12 vs 19±13;aOR 1.25;95%CI 1.02-1.54),无肾脏替代治疗天数更多(20±12 vs 19±13;aOR 1.35;95%CI 1.08-1.69)。结论认为,在大型随机试验的脓毒症患者中,使用平衡晶体液与较低的30天院内死亡率相关。

要点

  • 在SMART试验收入内科ICU的脓毒症患者中,平衡晶体液组30天院内死亡率为26.3%(217例),生理盐水组为31.2%(255例),校正后OR 0.74(95%CI 0.59-0.93;P=0.01)。
  • 平衡晶体液组30天内主要不良肾脏事件发生率为35.4%,生理盐水组为40.1%,校正后OR 0.78(95%CI 0.63-0.97)。
  • 平衡晶体液组无血管活性药物天数为20±12天,生理盐水组为19±13天,校正后OR 1.25(95%CI 1.02-1.54)。
  • 平衡晶体液组无肾脏替代治疗天数为20±12天,生理盐水组为19±13天,校正后OR 1.35(95%CI 1.08-1.69)。
  • 该分析为SMART试验的二次分析,采用多变量回归控制潜在混杂因素。

适用人群与场景

  • SMART试验中收入内科ICU且带有脓毒症ICD-10-CM编码的成人患者,共1641例。

研究设计与关键结果

  • 研究类型:SMART(等渗溶液与主要不良肾脏事件试验)的二次分析,纳入1641例收入内科ICU的脓毒症患者,采用多变量回归控制潜在混杂因素。
  • 主要终点:30天院内死亡率平衡晶体液组26.3%(217例)vs生理盐水组31.2%(255例),校正后OR 0.74(95%CI 0.59-0.93;P=0.01)。
  • 关键次要终点:30天内主要不良肾脏事件发生率平衡晶体液组35.4% vs生理盐水组40.1%,aOR 0.78(95%CI 0.63-0.97)。
  • 关键次要终点:无血管活性药物天数平衡晶体液组20±12天 vs生理盐水组19±13天,aOR 1.25(95%CI 1.02-1.54)。
  • 关键次要终点:无肾脏替代治疗天数平衡晶体液组20±12天 vs生理盐水组19±13天,aOR 1.35(95%CI 1.08-1.69)。

证据类型、等级与局限

  • 证据类型:随机对照试验(SMART)的二次分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在收入内科ICU的脓毒症患者中,使用平衡晶体液与较低的30天院内死亡率、较低的主要不良肾脏事件发生率以及更多的无血管活性药物天数和无肾脏替代治疗天数相关。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Rationale: Administration of intravenous crystalloid solutions is a fundamental therapy for sepsis, but the effect of crystalloid composition on patient outcomes remains unknown.Objectives: To compare the effect of balanced crystalloids versus saline on 30-day in-hospital mortality among critically ill adults with sepsis.Methods: Secondary analysis of patients from SMART (Isotonic Solutions and Major Adverse Renal Events Trial) admitted to the medical ICU with an International Classification of Diseases, 10th Edition, Clinical Modification System code for sepsis, using multivariable regression to control for potential confounders.Measurements and Main Results: Of 15,802 patients enrolled in SMART, 1,641 patients were admitted to the medical ICU with a diagnosis of sepsis. A total of 217 patients (26.3%) in the balanced crystalloids group experienced 30-day in-hospital morality compared with 255 patients (31.2%) in the saline group (adjusted odds ratio [aOR], 0.74; 95% confidence interval [CI], 0.59-0.93; P = 0.01). Patients in the balanced group experienced a lower incidence of major adverse kidney events within 30 days (35.4% vs. 40.1%; aOR, 0.78; 95% CI, 0.63-0.97) and a greater number of vasopressor-free days (20 ± 12 vs. 19 ± 13; aOR, 1.25; 95% CI, 1.02-1.54) and renal replacement therapy-free days (20 ± 12 vs. 19 ± 13; aOR, 1.35; 95% CI, 1.08-1.69) compared with the saline group.Conclusions: Among patients with sepsis in a large randomized trial, use of balanced crystalloids was associated with a lower 30-day in-hospital mortality compared with use of saline.Clinical trial registered with www.clinicaltrials.gov (NCT02444988).

来源:Am J Respir Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Brown RM, Wang L, Coston TD, et al. Balanced Crystalloids versus Saline in Sepsis. A Secondary Analysis of the SMART Clinical Trial. Am J Respir Crit Care Med. 2019. PMID: 31454263. doi:10.1164/rccm.201903-0557OC

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。