文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

严重脓毒症与脓毒性休克患者液体复苏的评估与预测因素

Evaluation and Predictors of Fluid Resuscitation in Patients With Severe Sepsis and Septic Shock.
PubMed 文献 · Crit Care Med · 2019-01-01
一句话结论回顾性队列显示未在脓毒症发作3小时内达到30 mL/kg晶体液团注与住院死亡率、延迟性低血压和ICU住院时间延长相关,但结论需未来验证。

该回顾性队列研究纳入2014年1月1日至2017年5月31日城市三级医疗中心急诊科治疗的成人严重脓毒症或脓毒性休克患者1032例,评估3小时内达到30 mL/kg晶体液团注(30by3)的预测因素及其对临床结局的影响。509例(49.3%)达到30by3;总死亡率17.1%,休克组死亡率20.4%。高龄、男性、肥胖、终末期肾病、心力衰竭或床旁检查记录容量超负荷者更少达到30by3。未达到30by3与住院死亡率增加(OR 1.52;95%CI 1.03-2.24)、延迟性低血压(OR 1.42;95%CI 1.02-1.99)和ICU住院时间延长约2天(β=2.0;95%CI 0.5-3.6)相关,且在高危组间无差异效应。3小时内给予更高液体量与死亡率降低相关,在35-45 mL/kg之间呈平台效应(p<0.05)。

要点

  • 1032例急诊成人严重脓毒症或脓毒性休克患者中,仅509例(49.3%)在脓毒症发作3小时内达到30 mL/kg晶体液团注(30by3)。
  • 未达到30by3与住院死亡率增加相关(OR 1.52;95%CI 1.03-2.24),且不受合并症影响。
  • 高龄(OR 0.62;95%CI 0.46-0.83)、男性(OR 0.66;95%CI 0.49-0.87)、肥胖(OR 0.18;95%CI 0.13-0.25)、终末期肾病(OR 0.23;95%CI 0.13-0.40)、心力衰竭(OR 0.42;95%CI 0.29-0.60)或记录容量超负荷(OR 0.30;95%CI 0.20-0.45)者更少达到30by3。
  • 未达到30by3还与延迟性低血压(OR 1.42;95%CI 1.02-1.99)和ICU住院时间延长约2天(β=2.0;95%CI 0.5-3.6)相关。
  • 3小时内给予更高液体量与死亡率降低相关,在35-45 mL/kg之间呈平台效应(p<0.05)。

适用人群与场景

  • 急诊科治疗的成人(年龄≥18岁)严重脓毒症或脓毒性休克患者,n=1,032。
  • 研究场所为城市三级医疗中心,时间范围为2014年1月1日至2017年5月31日。

研究设计与关键结果

  • 研究类型为回顾性队列研究;样本量n=1,032;单中心(城市三级医疗中心);人群为急诊科治疗的成人严重脓毒症或脓毒性休克患者。
  • 干预为静脉液体团注给药;主要分析为达到30by3(脓毒症发作3小时内30 mL/kg晶体液团注)的预测因素及30by3和液体剂量对临床结局的影响。
  • 509例(49.3%)达到30by3;总死亡率17.1%(n=176),休克组死亡率20.4%。
  • 达到30by3的预测因素:高龄OR 0.62(95%CI 0.46-0.83)、男性OR 0.66(95%CI 0.49-0.87)、肥胖OR 0.18(95%CI 0.13-0.25)、终末期肾病OR 0.23(95%CI 0.13-0.40)、心力衰竭OR 0.42(95%CI 0.29-0.60)、记录容量超负荷OR 0.30(95%CI 0.20-0.45),均更少达到30by3。
  • 未达到30by3与住院死亡率增加相关(OR 1.52;95%CI 1.03-2.24)、延迟性低血压(OR 1.42;95%CI 1.02-1.99)和ICU住院时间延长约2天(β=2.0;95%CI 0.5-3.6)相关,在高危组间无差异效应。
  • 3小时内给予更高液体量与死亡率降低相关,在35-45 mL/kg之间呈平台效应(p<0.05)。
  • 所有结局分析均控制了性别、终末期肾病、心力衰竭、脓毒症严重程度(严重脓毒症 vs 脓毒性休克)、肥胖、急诊科脓毒症死亡率评分(Mortality in Emergency Department Sepsis score)和抗生素使用时间。

证据类型、等级与局限

  • 证据类型:回顾性队列研究。
  • 局限:原文结论指出这些发现是回顾性的,需要未来验证。

对床旁实践的改变

  • 作者认为未达到30by3与住院死亡率增加相关,且不受合并症影响;不达标的预测因素可被识别,可能导向改善生存的干预。
  • 作者认为这些发现是回顾性的,需要未来验证。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: Rapid fluid resuscitation has become standard in sepsis care, despite "low-quality" evidence and absence of guidelines for populations "at risk" for volume overload. Our objectives include as follows: 1) identify predictors of reaching a 30 mL/kg crystalloid bolus within 3 hours of sepsis onset (30by3); 2) assess the impact of 30by3 and fluid dosing on clinical outcomes; 3) examine differences in perceived "at-risk" volume-sensitive populations, including end-stage renal disease, heart failure, obesity, advanced age, or with documentation of volume "overload" by bedside examination.

DESIGN: Retrospective cohort study. All outcome analyses controlled for sex, end-stage renal disease, heart failure, sepsis severity (severe sepsis vs septic shock), obesity, Mortality in Emergency Department Sepsis score, and time to antibiotics.

SETTING: Urban, tertiary care center between January 1, 2014, and May 31, 2017.

PATIENTS: Emergency Department treated adults (age ≥18 yr; n = 1,032) with severe sepsis or septic shock.

INTERVENTIONS: Administration of IV fluids by bolus.

MEASUREMENTS AND MAIN RESULTS: In total, 509 patients received 30by3 (49.3%). Overall mortality was 17.1% (n = 176), with 20.4% mortality in the shock group. Patients who were elderly (odds ratio, 0.62; 95% CI, 0.46-0.83), male (odds ratio, 0.66; CI, 0.49-0.87), obese (odds ratio, 0.18; CI, 0.13-0.25), or with end-stage renal disease (odds ratio, 0.23; CI, 0.13-0.40), heart failure (odds ratio, 0.42; CI, 0.29-0.60), or documented volume "overload" (odds ratio, 0.30; CI, 0.20-0.45) were less likely to achieve 30by3. Failure to meet 30by3 had increased odds of mortality (odds ratio, 1.52; CI, 1.03-2.24), delayed hypotension (odds ratio, 1.42; CI, 1.02-1.99), and increased ICU stay (~2 d) (β = 2.0; CI, 0.5-3.6), without differential effects for "at-risk" groups. Higher fluid volumes administered by 3 hours correlated with decreased mortality, with a plateau effect between 35 and 45 mL/kg (p < 0.05).

CONCLUSIONS: Failure to reach 30by3 was associated with increased odds of in-hospital mortality, irrespective of comorbidities. Predictors of inadequate resuscitation can be identified, potentially leading to interventions to improve survival. These findings are retrospective and require future validation.

来源:Crit Care Med,查看原文。版权归原作者所有。