超声心动图是外科危重患者心输出量的良好但不完美的测量方法
该前瞻性研究纳入84例患者(51例外科患者、33例非外科患者),同时用肺动脉导管热稀释法(CO-PAC)和经胸超声心动图(CO-TTE)测量心输出量。CO-TTE在外科患者中可测率为65%(33/51),非外科患者为79%(26/33),差异无统计学意义(p=0.17);两组失败的主因均为左室流出道直径无法测量(外科94%[17/18] vs 非外科86%[6/7],p=0.47)。两组相关性强(外科r=0.76,非外科r=0.86,均p<0.0001),Bland-Altman分析显示外科组偏倚-0.1 L/min、一致性界限-2.5至+2.3 L/min、百分比误差40%;非外科组偏倚+0.4 L/min、一致性界限-1.8至+2.5 L/min、百分比误差40%。作者结论认为两组相关性强、一致性中等,左室流出道直径无法测量是共同限制因素。
要点
- 外科ICU患者中CO-TTE可测率为65%(33/51),非外科患者为79%(26/33),差异无统计学意义(p=0.17)。
- 两组CO-TTE与CO-PAC均强相关:外科组r=0.76(p<0.0001),非外科组r=0.86(p<0.0001)。
- 外科组Bland-Altman偏倚-0.1 L/min、一致性界限-2.5至+2.3 L/min、百分比误差40%;非外科组偏倚+0.4 L/min、一致性界限-1.8至+2.5 L/min、百分比误差40%。
- 左室流出道直径无法测量是两组测量失败的主因:外科94%(17/18),非外科86%(6/7),p=0.47。
- 所有患者均可测量速度时间积分。
适用人群与场景
- 外科重症监护病房中留置肺动脉导管进行血流动力学监测的患者(SP)。
- 接受右心导管检查的非外科患者(NSP)。
研究设计与关键结果
- 前瞻性研究,18个月内纳入84例患者(51例外科患者、33例非外科患者),比较CO-TTE与CO-PAC。
- CO-TTE可测率:外科65%(33/51) vs 非外科79%(26/33),p=0.17。
- 测量失败主因为左室流出道直径无法测量:外科94%(17/18) vs 非外科86%(6/7),p=0.47;速度时间积分所有患者均可测量。
- CO-TTE与CO-PAC相关性:外科r=0.76(p<0.0001),非外科r=0.86(p<0.0001)。
- Bland-Altman一致性:外科组偏倚-0.1 L/min、一致性界限-2.5至+2.3 L/min、百分比误差40%;非外科组偏倚+0.4 L/min、一致性界限-1.8至+2.5 L/min、百分比误差40%。
证据类型、等级与局限
- 诊断试验研究,证据等级III级。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论认为,在外科与非外科患者中TTE与PAC测量CO均呈强相关、中等一致性,左室流出道直径无法测量是两组共同的限制因素。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Compared with a pulmonary artery catheter (PAC), transthoracic echocardiography (TTE) has been shown to have good agreement in cardiac output (CO) measurement in nonsurgical populations. Our hypothesis is that the feasibility and accuracy of CO measured by TTE (CO-TTE), relative to CO measured by PAC thermodilution (CO-PAC), is different in surgical intensive care unit patients (SP) and nonsurgical patients (NSP).
METHODS: Surgical patients with PAC for hemodynamic monitoring and NSP undergoing right heart catheterization were prospectively enrolled. Cardiac output was measured by CO-PAC and CO-TTE. Pearson coefficients were used to assess correlation. Bland-Altman analysis was used to determine agreement.
RESULTS: Over 18 months, 84 patients were enrolled (51 SP, 33 NSP). Cardiac output TTE could be measured in 65% (33/51) of SP versus 79% (26/33) of NSP; p = 0.17. Inability to measure the left ventricular outflow tract diameter was the primary reason for failure in both groups; 94% (17/18) in SP versus 86% (6/7) NSP; p = 0.47. Velocity time integral could be measured in all patients. In both groups, correlation between PAC and TTE measurement was strong; SP (r = 0.76; p < 0.0001), NSP (r = 0.86; p < 0.0001). Bland-Altman analysis demonstrated bias of -0.1 L/min, limits of agreement of -2.5 and +2.3 L/min, percentage error (PE) of 40% for SP, and bias of +0.4 L/min, limits of agreement of -1.8 and +2.5 L/min, and PE of 40% for NSP.
CONCLUSION: There was strong correlation and moderate agreement between TTE and PAC in both SP and NSP. In both patient populations, inability to measure the left ventricular outflow tract diameter was a limiting factor.
LEVEL OF EVIDENCE: Diagnostic tests or criteria, level III.
参考来源
- Olivieri PP, Patel R, Kolb S, et al. Echo is a good, not perfect, measure of cardiac output in critically ill surgical patients. J Trauma Acute Care Surg. 2019. PMID: 31349350. doi:10.1097/TA.0000000000002304
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。