心电图aVR导联ST段抬高对院外心脏骤停患者急性冠脉病变的诊断价值
本研究纳入74例院外心脏骤停复苏后无ST段抬高证据的患者,回顾性分析冠状动脉造影,检测自主循环恢复后即刻及早期随访时aVR导联ST段抬高程度。27%(20例)存在急性冠脉病变。自主循环恢复后即刻aVR导联ST段抬高在有或无急性冠脉病变患者间无差异,但无急性冠脉病变者早期随访(中位137分钟)时ST段抬高值显著下降。早期随访时aVR导联ST段抬高≥0.5 mm与多支冠状动脉病变高患病率相关,且为急性冠脉病变存在的独立指标(OR 4.41,95%CI 1.12-17.4,P=0.034)。作者认为aVR导联ST段抬高分析可能有助于识别将从进一步有创冠状动脉诊断操作中获益的患者。
要点
- 院外心脏骤停复苏后无典型ST段抬高者中,27%(20/74)经冠脉造影检出急性冠脉病变。
- 自主循环恢复后即刻aVR导联ST段抬高在有或无急性冠脉病变患者间无差异。
- 无急性冠脉病变者早期随访(中位137分钟)时aVR导联ST段抬高值显著下降。
- 早期随访aVR导联ST段抬高≥0.5 mm与多支冠脉病变高患病率相关,为急性冠脉病变独立指标(OR 4.41,95%CI 1.12-17.4,P=0.034)。
- 作者认为aVR导联ST段抬高分析可能有助于识别将从进一步有创冠状动脉诊断操作中获益的患者。
适用人群与场景
- 院外心脏骤停复苏后无ST段抬高证据的患者,共74例。
诊断标准与关键阈值
- 早期随访时aVR导联ST段抬高≥0.5 mm作为急性冠脉病变的关联指标(OR 4.41,95%CI 1.12-17.4,P=0.034)。
研究设计与关键结果
- 回顾性分析74例院外心脏骤停复苏后无ST段抬高证据的患者,检测自主循环恢复后即刻及早期随访时aVR导联ST段抬高程度,回顾冠脉造影。
- 急性冠脉病变检出20例(27%)。
- 自主循环恢复后即刻aVR导联ST段抬高在有或无急性冠脉病变患者间无差异。
- 无急性冠脉病变者早期随访(中位137分钟)时aVR导联ST段抬高值显著下降。
- 早期随访aVR导联ST段抬高≥0.5 mm与多支冠状动脉病变高患病率相关,为急性冠脉病变存在的独立指标(OR 4.41,95%CI 1.12-17.4,P=0.034)。
证据类型、等级与局限
- 证据类型:回顾性分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,aVR导联ST段抬高分析可能有助于识别院外心脏骤停复苏后无其他ST段抬高患者中将从进一步有创冠状动脉诊断操作中获益者。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
AIM: There is no simple clinical tool that reliably indicates the presence of acute coronary lesions in out-of-hospital cardiac arrest (OHCA) patients without typical ST-segment elevations. ST-segment elevation in electrocardiographic lead aVR suggests global subendocardial ischemia. This study aimed to evaluate the diagnostic value of lead aVR for identifying acute coronary lesions following resuscitation from OHCA.
METHODS: A total of 74 patients without evidence of ST-segment elevations, who were resuscitated from OHCA, were examined. The degree of ST-segment elevation in lead aVR was measured directly after return of spontaneous circulation (ROSC) and at early follow-up. Coronary angiograms were retrospectively reviewed.
RESULTS: Acute coronary lesions were detected in 20 patients (27%). No difference in ST-segment elevation in lead aVR directly after ROSC was observed between patients with or without acute coronary lesions. However, ST-segment elevation values significantly decreased at early follow-up (median, 137 min) in patients without acute coronary lesions. An ST-segment elevation ≥0.5 mm in lead aVR at early follow-up was associated with a higher prevalence of multivessel coronary artery disease and was an independent indicator of the presence of acute coronary lesions (odds ratio, 4.41; 95% confidence interval, 1.12-17.4; p = 0.034).
CONCLUSION: ST-segment elevation in lead aVR at early follow-up was associated with the presence of acute lesions accompanied by severe coronary artery disease in post-cardiac arrest patients without other ST-segment elevations. The analysis of ST-segment elevation in lead aVR may aid in the identification of patients who will benefit from further invasive coronary diagnostic procedures.
参考来源
- Yamamoto M, Witsch T, Kubota S, et al. Diagnostic value of lead aVR in electrocardiography for identifying acute coronary lesions in patients with out-of-hospital cardiac arrest. Resuscitation. 2019. PMID: 31330201. doi:10.1016/j.resuscitation.2019.07.017
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。