文献速递心脑血管急症重症综合管理与镇静镇痛

氧输送不足指数剂量与新生儿体外循环术后心脏骤停风险相关

Inadequate oxygen delivery index dose is associated with cardiac arrest risk in neonates following cardiopulmonary bypass surgery.
PubMed 文献 · Resuscitation · 2019-07-17
一句话结论新生儿体外循环术后120分钟窗内氧输送不足指数剂量越高,心脏骤停风险越高,单心室患者中关联更强。

该回顾性队列研究纳入3个美国儿童心脏重症监护单元中601例体外循环术后新生儿,评估氧输送不足(IDO2)指数剂量对心脏骤停(CA)的预测价值。IDO2指数值对床旁临床医生设盲,取CA或对照事件前30分钟至前120分钟窗口计算IDO2剂量。多变量逻辑回归模型纳入IDO2剂量和单心室(SV)状态,IDO2剂量系数的OR为1.008(95%CI 1.006-1.012,P=0.0445),SV的OR为2.952(95%CI 2.952-3.258,P=0.0079),联合模型ROC AUC为0.74(95%CI 0.73-0.75)。结论认为术后120分钟监测期内较高的IDO2指数剂量与心脏骤停风险增加相关,即使删失CA事件前10、20或30分钟数据,关联仍然稳健。

要点

  • 新生儿体外循环术后120分钟窗内IDO2指数剂量升高与心脏骤停风险增加相关(OR 1.008,95%CI 1.006-1.012,P=0.0445)。
  • 单心室状态与心脏骤停风险独立相关(OR 2.952,95%CI 2.952-3.258,P=0.0079)。
  • 联合IDO2剂量与单心室状态的预测模型ROC AUC为0.74(95%CI 0.73-0.75)。
  • 即使删失心脏骤停前10、20或30分钟数据,IDO2剂量与心脏骤停风险的关联仍然稳健。
  • 29例患者发生心脏骤停(33次事件),其中17例(59%)为单心室患者;对照组572例中125次事件(26%)发生于单心室患者。

适用人群与场景

  • 3个美国儿童心脏重症监护单元中体外循环术后新生儿,研究期间2011年1月至2016年8月。
  • 601例符合纳入标准;29例发生心脏骤停(33次事件),572例用于对照事件。

诊断标准与关键阈值

  • IDO2剂量在心脏骤停或对照事件前30分钟至前120分钟窗口内计算。
  • IDO2指数值对床旁临床医生设盲。
  • 数据收集至术后30天,或至死亡或启动ECMO。

研究设计与关键结果

  • 回顾性队列研究,3个美国儿童心脏重症监护单元,601例体外循环术后新生儿。
  • 29例发生心脏骤停(33次事件),572例用于对照事件;单心室患者占CA事件的59%(17例)和对照事件的26%(125次)。
  • 两组手术时中位年龄/体重和监测级别相似;CA患者术后中位事件时间0.73天[0.05-22.39],对照患者0.82天[0.08-25.11]。
  • IDO2剂量系数OR为1.008(95%CI 1.006-1.012,P=0.0445),单心室OR为2.952(95%CI 2.952-3.258,P=0.0079)。
  • 联合模型ROC AUC为0.74(95%CI 0.73-0.75)。
  • 即使删失心脏骤停前10、20或30分钟数据,IDO2剂量与CA风险的关联仍然稳健。

证据类型、等级与局限

  • 证据类型:回顾性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 原文结论:体外循环术后新生儿120分钟监测期内较高的IDO2指数剂量与心脏骤停风险增加相关,即使删失CA事件前10、20或30分钟数据。
  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM: To evaluate the Inadequate oxygen delivery (IDO2) index dose as a predictor of cardiac arrest (CA) in neonates following congenital heart surgery.

METHODS: Retrospective cohort study in 3 US pediatric cardiac intensive units (1/2011- 8/2016). Calculated IDO2 index values were blinded to bedside clinicians and generated from data collected up to 30 days postoperatively, or until death or ECMO initiation. Control event data was collected from patients who did not experience CA or require ECMO. IDO2 dose was computed over a 120-min window up to 30 min prior to the CA and control events. A multivariate logistic regression prediction model including the IDO2 dose and presence or absence of a single ventricle (SV) was used. Model performance metrics were the odds ratio for each regression coefficient and receiver operating characteristic area under the curve (ROC AUC).

RESULTS: Of 897 patients monitored during the study period, 601 met inclusion criteria: 29 patients had CA (33 events) and 572 patients were used for control events. Seventeen (59%) CA and 125 (26%) control events occurred in SV patients. Median age/weight at surgery and level of monitoring were similar in both groups. Median postoperative event time was 0.73 days [0.05-22.39] in CA patients and 0.82 days [0.08 25.11] in control patients. Odds ratio of the IDO2 dose coefficient was 1.008 (95% CI: 1.006-1.012, p = 0.0445), and 2.952 (95% CI: 2.952-3.258, p = 0.0079) in SV. The ROC AUC using both coefficients was 0.74 (95% CI: 0.73-0.75). These associations of IDO2 dose with CA risk remained robust, even when censored periods prior to arrest were 10 and 20 min.

CONCLUSION: In neonates post-CPB surgery, higher IDO2 index dose over a 120-min monitoring period is associated with increased risk of cardiac arrest, even when censoring data 10, 20 or 30 min prior to the CA event.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Futterman C, Salvin JW, McManus M, et al. Inadequate oxygen delivery index dose is associated with cardiac arrest risk in neonates following cardiopulmonary bypass surgery. Resuscitation. 2019. PMID: 31325555. doi:10.1016/j.resuscitation.2019.07.013

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。