文献速递复苏、休克与脓毒症

智能设备对心肺复苏培训质量的影响:一项系统评价

Effect of smart devices on the quality of CPR training: A systematic review.
PubMed 文献 · Resuscitation · 2019-07-17
一句话结论系统评价未发现智能设备在CPR培训中维持推荐按压速率和深度的持久获益,但智能手表可能提高胸外按压深度的准确性。

该系统评价检索13个电子数据库,最终纳入11项研究(5项随机对照试验、1项随机试验、5项随机交叉试验),其中8项使用智能手机、3项使用智能手表。以胸外按压速率、深度及足够深度按压比例评估CPR质量。结果未发现智能设备在维持推荐按压速率和深度方面有明显获益;但三项智能手表研究均报告足够深度按压比例显著改善(智能手表组 vs 非智能手表组:65.01% vs 45.15%,p=0.01;64.6% vs 43.1%,p=0.049;98.7% vs 79.3%,p=0.002)。结论认为智能设备在CPR培训中的效用缺乏持久证据,智能手表可能提高按压深度准确性,需更大样本研究方能定论。

要点

  • 系统评价纳入11项研究(5项RCT、1项随机试验、5项随机交叉试验),未发现智能设备在CPR培训中维持推荐按压速率和深度的明显获益。
  • 三项智能手表研究均显示足够深度按压比例显著改善:65.01% vs 45.15%(p=0.01)、64.6% vs 43.1%(p=0.049)、98.7% vs 79.3%(p=0.002)。
  • 八项研究使用智能手机、三项使用智能手表,智能设备的获益主要体现在智能手表对按压深度准确性的改善。
  • 作者认为智能手表可能提高胸外按压深度的准确性,但需更大样本研究才能得出确切结论。

适用人群与场景

  • 接受心肺复苏培训的研究对象;原文未报告具体纳入与排除人群特征。

诊断标准与关键阈值

  • CPR质量基于胸外按压速率、按压深度及足够深度按压比例进行评估。

研究设计与关键结果

  • 系统评价共纳入11项研究(5项随机对照试验、1项随机试验、5项随机交叉试验),其中8项使用智能手机、3项使用智能手表。
  • 未发现智能设备在CPR培训中维持推荐按压速率和按压深度方面有明显获益。
  • 三项智能手表研究均报告足够深度按压比例显著改善:智能手表组 vs 非智能手表组分别为65.01% vs 45.15%(p=0.01)、64.6% vs 43.1%(p=0.049)、98.7% vs 79.3%(p=0.002)。

证据类型、等级与局限

  • 证据类型:系统评价,纳入5项随机对照试验、1项随机试验和5项随机交叉试验。
  • 局限:原文未报告局限性;作者指出需更大样本研究才能得出确切结论。

对床旁实践的改变

  • 该系统评价未发现智能设备在CPR培训中维持推荐按压速率和深度的持久获益,不支持将智能设备作为改善CPR培训质量的常规手段。
  • 作者认为智能手表可能提高胸外按压深度的准确性,但需更大样本研究验证。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM OF THE REVIEW: Use of smart devices to provide real-time cardiopulmonary resuscitation (CPR) feedback in the context of out-of-hospital cardiac arrest (OHCA) has considerable potential for improving survival. However, the findings of previous studies evaluating the effectiveness of these devices have been conflicting. Therefore, we conducted a systematic review of the literature to assess the utility of smart devices for improving the quality of CPR during CPR training.

DATA SOURCES: Thirteen electronic databases were searched. The articles were reviewed according to the eligibility criteria. CPR quality was evaluated based on the rates and depths of chest compression, and the proportion of adequate depth of chest compressions.

RESULTS: Ultimately, 11 studies (5 randomised controlled trials, 1 randomised trial, and 5 randomised cross-over trials) were selected for this systematic review. Eight of these studies used smartphones and three used smartwatches. This review did not find an apparent benefit from smart device use during CPR in terms of maintaining the recommended compression rates and depths of chest compressions. However, all three smartwatch studies reported that the proportion of chest compressions of adequate depth was significantly improved with smartwatch use (smartwatch group vs. non-smartwatch group in the three studies: 65.01% vs. 45.15%, p = 0.01; 64.6% vs. 43.1%, p = 0.049; 98.7% vs. 79.3%, p = 0.002).

CONCLUSION: This review does not find durable evidence for usefulness of smart devices in CPR training. However, the smartwatches may improve the accuracy of chest compression depth. Future studies with larger sample sizes might be necessary before reaching a firm conclusion.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. An M, Kim Y, Cho WK, et al. Effect of smart devices on the quality of CPR training: A systematic review. Resuscitation. 2019. PMID: 31325556. doi:10.1016/j.resuscitation.2019.07.011

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。