文献速递复苏、休克与脓毒症

救生艇船员实施心肺复苏的环境、结局与质量

Circumstances, outcome and quality of cardiopulmonary resuscitation by lifeboat crews.
PubMed 文献 · Resuscitation · 2019-07-24
一句话结论荷兰皇家救生艇协会2011年7月至2017年12月共37例旁观者心肺复苏,1个月存活3例(8.1%),自动体外除颤器未贡献任何存活。

该研究利用荷兰皇家救生艇协会(KNRM)内部数据库,分析2011年7月至2017年12月由救生艇船员实施的院外心脏骤停心肺复苏病例,共37例,其中29例(78.4%)发生在恶劣条件下,到达现场中位响应时间15分钟。11例(29.7%)在复苏过程中任一时刻实现自主循环恢复,3例(8.1%)一个月后仍存活。救生艇自动体外除颤器(AED)用于12例患者,记录显示中位按压频率120次/分(IQR 111-131),但中断时间延长(分析前停顿11秒、分析后4秒、电击前24秒、电击后6秒、通气6秒、其他9秒)。结论认为救生艇船员复苏发生率低、环境困难、人群较年轻,AED未贡献任何存活,AED信息分析可用于改进未来培训。

要点

  • 37例由救生艇船员实施心肺复苏的院外心脏骤停中,29例(78.4%)发生在恶劣条件下,到达现场中位响应时间15分钟。
  • 11例(29.7%)在复苏过程中任一时刻实现自主循环恢复,3例(8.1%)一个月后仍存活。
  • 救生艇AED用于12例患者,未贡献任何存活。
  • AED记录显示中位按压频率120次/分(IQR 111-131),但中断时间延长:分析前停顿中位11秒(IQR 10-13),电击前停顿中位24秒(IQR 19-26)。
  • 作者认为AED信息分析可用于研究心肺复苏质量,并为改进救生艇船员未来培训提供输入。

适用人群与场景

  • 2011年7月至2017年12月期间由荷兰皇家救生艇协会(KNRM)救生艇船员实施心肺复苏的院外心脏骤停患者,共37例。

研究设计与关键结果

  • 研究类型为利用KNRM内部数据库的病例分析,共纳入37例由救生艇船员实施心肺复苏的院外心脏骤停患者。
  • 29例(78.4%)心肺复苏发生在恶劣条件下,到达现场中位响应时间15分钟。
  • 11例(29.7%)在复苏过程中任一时刻实现自主循环恢复,3例(8.1%)一个月后仍存活。
  • 救生艇AED用于12例患者,其记录显示中位按压频率120次/分(IQR 111-131)。
  • AED记录的中断时间:分析前停顿中位11秒(IQR 10-13),分析后停顿中位4秒(IQR 3-8),电击前停顿中位24秒(IQR 19-26),电击后停顿中位6秒(IQR 6-11),通气停顿中位6秒(IQR 4-8),其他停顿中位9秒(IQR 4-17)。
  • 救生艇AED未贡献任何存活。

证据类型、等级与局限

  • 证据类型:基于登记数据库的病例分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为AED信息分析可用于研究心肺复苏质量,并为改进救生艇船员未来培训提供输入。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Little is known regarding circumstances, outcomes and quality of cardiopulmonary resuscitation (CPR) and the use of automated external defibrillators (AEDs) performed by operational lifeboat crews. Our aim is to evaluate circumstances, outcomes and quality of CPR performed by the Royal Dutch Lifeboat Institution (KNRM) in out-of-hospital cardiac arrest (OHCA).

METHODS: The internal KNRM database has been used to identify and analyse all OHCA cases between July 2011 and December 2017. A limited set of AED data was available to study the quality of CPR.

RESULTS: In 37 patients the lifeboat crew members have performed CPR, of which 29 (78.4%) occurred under hostile conditions. The median response time to arrive at the location was 15min. In 11 (29.7%) patients return of spontaneous circulation was achieved at any moment during CPR and 3 (8.1%) patients were still alive after one month. The lifeboat AED was used in 12 patients. Their recordings show a high median compression frequency (120, IQR 111-131) and prolonged median interruption periods (pre-analysis pause 11s (IQR 10-13), post-analysis pause 4s (IQR 3-8), pre-shock pause 24s (IQR 19-26), post-shock pause 6s (IQR 6-11), ventilation pause 6s (IQR 4-8) and other pauses 9s (IQR 4-17)).

CONCLUSIONS: Compared to most out-of-hospital resuscitations, resuscitations by lifeboat crews have a low incidence, occur under difficult circumstances and in a younger population. AED's on lifeboats have not contributed to any of the survivals. Analysis of AED information can be used to study the quality of CPR and provide input for improving future training of lifeboat crews.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Seesink J, Nieuwenburg SAV, van der Linden T, et al. Circumstances, outcome and quality of cardiopulmonary resuscitation by lifeboat crews. Resuscitation. 2019. PMID: 31351088. doi:10.1016/j.resuscitation.2019.07.012

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。