文献速递复苏、休克与脓毒症创伤与烧伤

平民成人创伤患者骨骼标志与血管解剖的计算机断层扫描相关性:对复苏性主动脉腔内球囊阻断术的启示

Computed tomography correlation of skeletal landmarks and vascular anatomy in civilian adult trauma patients: Implications for resuscitative endovascular balloon occlusion of the aorta.
PubMed 文献 · J Trauma Acute Care Surg · 2019-01-01
一句话结论基于CT形态学测量,复苏性主动脉腔内球囊阻断术(REBOA)导管固定插入长度在I区为48 cm、III区为28 cm(适用于平均身高个体),按躯干范围(TE)公式调整可减少异位放置。

该研究为单中心回顾性影像分析,纳入2000至2015年间2247例有CT影像的创伤患者,其中1789例胸腹盆动脉系统对比剂充盈充分者被用于分析。采用MATLAB定制高通量图像处理算法将血管中心线与骨骼肌肉标志进行相关性分析。结果显示,右侧皮肤穿刺点至主动脉分叉的中心线距离比左侧长0.3 cm;I区主动脉中位长度为21.6 cm(IQR 20.3–22.9),III区为8.7 cm(IQR 7.8–9.5)。躯干范围(TE)与I区的相关性明显高于III区(R² 0.58 vs 0.26(右)和0.58 vs 0.27(左),p<0.001)。假设球囊长度4 cm,I区和III区的最佳固定插入长度分别为48 cm和28 cm(误差0.4% vs 33.3%),按TE调整后异位放置误差可降至0% vs 26.4%。作者认为,III区放置的高残余误差可能需要重新设计现有导管球囊长度,或考虑球囊放置过低或过高的相对风险。

要点

  • 在平均身高个体中,REBOA导管固定插入长度I区为48 cm、III区为28 cm(假设球囊长度4 cm),对应异位放置误差分别为0.4%和33.3%。
  • 按躯干范围(TE)公式调整后,I区和III区的异位放置误差分别降至0%和26.4%。
  • 躯干范围(TE)与I区主动脉长度的相关性明显高于III区(R² 0.58 vs 0.26(右)和0.58 vs 0.27(左),p<0.001)。
  • 右侧皮肤穿刺点至主动脉分叉的中心线距离比左侧长0.3 cm。
  • I区主动脉中位长度21.6 cm(IQR 20.3–22.9),III区8.7 cm(IQR 7.8–9.5)。

适用人群与场景

  • 平民成人创伤患者,2000至2015年间单中心三级医疗中心行CT成像且胸腹盆动脉系统对比剂充盈充分者(1789例)。

研究设计与关键结果

  • 研究类型:单中心回顾性CT形态学分析;样本量:2247例创伤患者行CT成像,其中1789例动脉对比剂充盈充分纳入分析。
  • 主要结果:右侧皮肤穿刺点至主动脉分叉中心线距离比左侧长0.3 cm;I区主动脉中位长度21.6 cm(IQR 20.3–22.9),III区8.7 cm(IQR 7.8–9.5)。
  • TE与I区相关性R² 0.58(右)和0.58(左),与III区R² 0.26(右)和0.27(左),p<0.001。
  • 假设球囊长度4 cm,最佳固定插入长度I区48 cm、III区28 cm,异位放置误差分别为0.4%和33.3%;按TE调整后误差分别为0%和26.4%。

证据类型、等级与局限

  • 证据类型:回顾性影像分析(预后/流行病学),证据等级III级。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,对于平均身高个体,REBOA导管固定插入长度I区48 cm、III区28 cm为最佳(基于CT形态学测量)。
  • 作者认为,按躯干范围(TE)公式调整可提高放置准确性。
  • 作者认为,III区放置的高残余误差可能需要重新设计现有导管球囊长度,或考虑球囊放置过低或过高的相对风险。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a valuable resuscitative adjunct in a variety of clinical settings. In resource-limited or emergency environments, REBOA may be required with delayed or absent image-guidance or verification. Catheter insertion lengths may be informed by making computed tomography (CT) correlations of skeletal landmarks with vascular lengths.

METHODS: Between 2000 and 2015 at a single civilian tertiary care center, 2,247 trauma patients with CT imaging were identified, yielding 1,789 patients with adequate contrast opacification of the arterial system in the chest, abdomen, and pelvis. Individual scans were analyzed using MATLAB software, with custom high-throughput image processing algorithms applied to correlate centerline vascular anatomy with musculoskeletal landmarks. Data were analyzed using R version 3.3.

RESULTS: The median centerline distance from the skin access to the aortic bifurcation was longer by 0.3 cm on the right than on the left side. Median aortic zone I length was 21.6 (interquartile range, 20.3-22.9) cm, while zone III was 8.7 (7.8-9.5) cm. Torso extent (TE) correlation to zone I was much higher than that for zone III (R2, 0.58 vs. 0.26 (right) and 0.58 vs. 0.27 (left); p < 0.001). Assuming a 4-cm balloon length, optimal fixed insertion length would be 48 cm and 28 cm for zones I and III (error, 0.4% vs. 33.3%), respectively, although out of zone placements can be reduced if adjusted for TE (error, 0% vs. 26.4%).

CONCLUSION: Computed tomography morphometry suggests that a fixed REBOA catheter insertion length of 48 cm for zone I and 28 cm for zone III is optimal (on average, for average-height individuals), with improved accuracy by formulaic adjustments for TE. High residual error for zone III placement may require redesign of existing catheter balloon lengths or consideration of the relative risk associated with placing the balloon catheter too low or too high.

LEVEL OF EVIDENCE: Prognostic/epidemiological, level III.

来源:J Trauma Acute Care Surg,查看原文。版权归原作者所有。

参考来源

  1. Eliason JL, Derstine BA, Horbal SR, et al. Computed tomography correlation of skeletal landmarks and vascular anatomy in civilian adult trauma patients: Implications for resuscitative endovascular balloon occlusion of the aorta. J Trauma Acute Care Surg. 2019. PMID: 31246918. doi:10.1097/TA.0000000000002247

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。