相位对比CT在体表征损伤兔肺的个体气道闭合
该研究为实验室动物研究,在6只新西兰白兔中于基线及肺损伤后(全肺灌洗加损伤性通气,4只)使用同步辐射相位对比CT(体素47.5×47.5×47.5 μm)在呼气末正压12至0 cm H2O下测量同一外周气道的横截面。基线48条气道中3条(6.3%)在0 cm H2O闭合,损伤后32条中5条(15.6%)闭合。损伤后在3和0 cm H2O横截面显著减小,且横截面相对变化与12 cm H2O时气道半径显著相关(R=0.60;p<0.001),正常肺无此关系。结论提示损伤肺气道塌陷性增加并依赖气道口径,识别出「顺应性塌陷」为主要闭合机制。
要点
- 在损伤兔肺中,同一外周气道的横截面在呼气末正压3和0 cm H2O时较基线显著减小。
- 基线时48条气道中3条(6.3%)在呼气末正压0 cm H2O闭合;损伤后32条中5条(15.6%)闭合。
- 损伤肺中气道横截面相对变化与呼气末正压12 cm H2O时气道半径显著相关(R=0.60;p<0.001),正常肺无此关系。
- 初始开放气道的主要闭合机制被识别为「顺应性塌陷」,且可在同一气道的多个位点发生。
- 研究使用同步辐射相位对比CT在体测量同一气道,体素尺寸47.5×47.5×47.5 μm。
适用人群与场景
- 6只新西兰白兔,麻醉、麻痹后以压力控制模式机械通气(潮气量6 mL/kg;呼吸频率40;FIO2 0.6;吸呼比1:2;呼气末正压3 cm H2O)作为基线。
- 其中4只在全肺灌洗和损伤性通气诱导肺损伤后重复成像。
研究设计与关键结果
- 实验室动物研究:6只新西兰白兔,基线测量48条气道(半径1.7至0.21 mm),损伤后测量32条气道。
- 基线时呼气末正压0 cm H2O下48条气道中3条(6.3%)闭合,其呼气末正压12 cm H2O时半径为0.35±0.08 mm;损伤后32条中5条(15.6%)闭合,半径为0.28±0.09 mm。
- 损伤后在呼气末正压3和0 cm H2O时气道横截面显著减小,且横截面相对变化与呼气末正压12 cm H2O时气道半径显著相关(R=0.60;p<0.001),正常肺无此关系。
- 成像在呼气末正压12、9、6、3、0 cm H2O下进行,体素尺寸47.5×47.5×47.5 μm,使用同步辐射相位对比CT。
证据类型、等级与局限
- 证据类型:实验室动物研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,损伤肺中气道塌陷性增加并显著依赖气道口径,初始开放气道的主要闭合机制为「顺应性塌陷」,可在同一气道的多个位点发生。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: Airway closure is involved in adverse effects of mechanical ventilation under both general anesthesia and in acute respiratory distress syndrome patients. However, direct evidence and characterization of individual airway closure is lacking. Here, we studied the same individual peripheral airways in intact lungs of anesthetized and mechanically ventilated rabbits, at baseline and following lung injury, using high-resolution synchrotron phase-contrast CT.
DESIGN: Laboratory animal investigation.
SETTING: European synchrotron radiation facility.
SUBJECTS: Six New-Zealand White rabbits.
INTERVENTIONS: The animals were anesthetized, paralyzed, and mechanically ventilated in pressure-controlled mode (tidal volume, 6 mL/kg; respiratory rate, 40; FIO2, 0.6; inspiratory:expiratory, 1:2; and positive end-expiratory pressure, 3 cm H2O) at baseline. Imaging was performed with a 47.5 × 47.5 × 47.5 μm voxel size, at positive end-expiratory pressure 12, 9, 6, 3, and 0 cm H2O. The imaging sequence was repeated after lung injury induced by whole-lung lavage and injurious ventilation in four rabbits. Cross-sections of the same individual airways were measured.
MEASUREMENTS AND MAIN RESULTS: The airways were measured at baseline (n = 48; radius, 1.7 to 0.21 mm) and after injury (n = 32). Closure was observed at 0 cm H2O in three of 48 airways (6.3%; radius, 0.35 ± 0.08 mm at positive end-expiratory pressure 12) at baseline and five of 32 (15.6%; radius, 0.28 ± 0.09 mm) airways after injury. Cross-section was significantly reduced at 3 and 0 cm H2O, after injury, with a significant relation between the relative change in cross-section and airway radius at 12 cm H2O in injured, but not in normal lung (R = 0.60; p < 0.001).
CONCLUSIONS: Airway collapsibility increases in the injured lung with a significant dependence on airway caliber. We identify "compliant collapse" as the main mechanism of airway closure in initially patent airways, which can occur at more than one site in individual airways.
参考来源
- Broche L, Pisa P, Porra L, et al. Individual Airway Closure Characterized In Vivo by Phase-Contrast CT Imaging in Injured Rabbit Lung. Crit Care Med. 2019. PMID: 31162202. doi:10.1097/CCM.0000000000003838