文献速递重症综合管理与镇静镇痛复苏、休克与脓毒症

床旁手背静脉观察无创评估中心静脉压

Bedside hand vein inspection for noninvasive central venous pressure assessment.
PubMed 文献 · Am J Emerg Med · 2019-04-26
一句话结论手背静脉塌陷高度法在ICU中总体准确性中等,但识别低中心静脉压(<7 mmHg)敏感性92%、阴性预测值98%。

研究在82例ICU患者中评估手背静脉塌陷高度(HVC)无创估测中心静脉压(CVP)的可行性与准确性,以有创CVP为金标准。患者中位年龄67岁,中位CVP 12 mmHg,HVC与CVP的中位绝对差为4 mmHg,Spearman相关系数0.55(95%CI 0.35-0.69)。CVP分类总体正确率45%;HVC对低CVP(<7 mmHg)敏感性92%、阴性预测值98%,对高CVP(>12 mmHg)敏感性29%但特异性94%。作者认为该方法在ICU总体表现仅中等,但能高敏感识别低CVP。

要点

  • 在82例ICU患者中,HVC与有创CVP的中位绝对差为4 mmHg,Spearman相关系数0.55(95%CI 0.35-0.69)。
  • HVC对低CVP(<7 mmHg)敏感性92%、阴性预测值98%,可用于排除低CVP。
  • HVC对高CVP(>12 mmHg)敏感性仅29%、特异性94%,阳性时提示高CVP但阴性不能排除。
  • CVP分类(低<7、正常7-12、高>12 mmHg)总体正确率仅45%,总体准确性中等。
  • 测量方法为缓慢抬高手部观察手背静脉塌陷,记录手背至换能器空气零点端口的垂直距离并转换为mmHg。

适用人群与场景

  • 82例ICU患者,中位年龄67岁(IQR 60-74),中位CVP 12 mmHg(IQR 8-15)。

诊断标准与关键阈值

  • CVP分类界值:低<7 mmHg,正常7-12 mmHg,高>12 mmHg。
  • HVC测量:缓慢抬高手部观察手背静脉塌陷,记录手背至换能器空气零点端口的垂直距离并转换为mmHg,观察者对同步CVP值盲法。

研究设计与关键结果

  • 研究类型为诊断准确性研究,样本量82例,以有创CVP为金标准评估HVC估测CVP的可行性与准确性。
  • HVC与CVP的中位绝对差为4 mmHg(IQR 2-7),Spearman相关系数0.55(95%CI 0.35-0.69)。
  • CVP分类总体正确率45%;HVC对低CVP敏感性92%、阴性预测值98%;高HVC对高CVP敏感性29%、特异性94%。

证据类型、等级与局限

  • 证据类型:诊断准确性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,观察手背静脉塌陷估测CVP在ICU总体表现仅中等,但中位差低,且HVC能以高敏感性和极好阴性预测值识别低CVP。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Rapid estimates of the central venous pressure (CVP) can be helpful to administer early fluid therapy or to manage cardiac preload in intensive care units, operating rooms or emergency rooms in order to start and monitor an adequate medical therapy. Invasive CVP measurements have inherent and non-negligible complication rates as well as great expenditures. Several noninvasive methods of CVP measurements, like ultrasound-guided techniques, are available, but require trained skills and special equipment which might not be at hand in all situations. Our purpose was to evaluate the feasibility and accuracy of CVP estimates assessed upon the height of hand veins collapse (HVC) using invasively measured CVP as the gold standard. The HVC was determined by slowly lifting the patient's hand while watching the dorsal hand veins to collapse. The vertical distance from the dorsal hand to a transducer air zero port was noted and converted to mmHg. The observer was blinded to the simultaneously measured CVP values, which were categorized as low (<7 mmHg), normal (7-12 mmHg) and high (>12 mmHg). Measurements were performed in 82 patients who had a median [IQR] age of 67 [60;74]. Median CVP was 12 [8;15] mmHg and the median absolute difference between the measured HVC and CVP was 4 [2;7] mmHg. The Spearman correlation coefficient between CVP and HVC was 0.55, 95%-CI [0.35;0.69]. Overall CVP categorization was correct in 45% of the cases. HVC had a sensitivity of 92% for a low CVP with a negative predictive value of 98%. A high HVC had a sensitivity of 29% but a high specificity of 94% for a high CVP. The overall performance of observing the hand vein collapse to estimate CVP was only moderate in the intensive care setting. However, the median difference to the CVP was low and HVC identifies a low CVP with a high sensitivity and excellent negative predictive value.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Vogel F, Staub D, Aschwanden M, et al. Bedside hand vein inspection for noninvasive central venous pressure assessment. Am J Emerg Med. 2019. PMID: 31088750. doi:10.1016/j.ajem.2019.04.044

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。