文献速递复苏、休克与脓毒症创伤与烧伤

复苏性主动脉内球囊阻断所致心肌损伤可被血管内可变主动脉控制减轻

Resuscitative endovascular balloon occlusion of the aorta induced myocardial injury is mitigated by endovascular variable aortic control.
PubMed 文献 · J Trauma Acute Care Surg · 2019-01-01
一句话结论在猪失血性休克模型中,完全性主动脉阻断导致心肌损伤,而血管内可变主动脉控制(EVAC)可减轻该损伤并改善复苏期和重症监护期的心脏功能。

研究在18只麻醉猪中诱导25%血容量失血,随机分为Zone 1复苏性主动脉内球囊阻断(REBOA)组、Zone 1血管内可变主动脉控制(EVAC)组和无干预对照组,干预45分钟后用失血回输复苏并观察至6小时。干预期间REBOA组平均心输出量高于EVAC组和对照组,但6小时后REBOA组血清肌钙蛋白浓度高于EVAC组和对照组,且REBOA组心肌壁内出血高于对照组。EVAC组前负荷可复性每搏功在整个实验期间维持较高水平,而REBOA组未能维持。结论认为完全性主动脉阻断导致心肌损伤,EVAC可减轻心肌损伤并改善心脏性能。

要点

  • 在猪失血性休克模型中,Zone 1 REBOA干预45分钟导致6小时后血清肌钙蛋白升高至6.26 ± 5.35 ng/mL,高于EVAC组0.92 ± 0.61 ng/mL(p=0.05)和对照组0.65 ± 0.38 ng/mL(p=0.03)。
  • REBOA组心肌壁内出血评分高于对照组(1.67 ± 0.46 vs. 0.17 ± 0.18,p=0.03),EVAC组与对照组之间无此差异。
  • 干预期间平均心输出量REBOA组为9.3(8.6-15.4)L/min,高于EVAC组7.2(5.8-8.0)L/min(p=0.01)和对照组6.8(5.8-7.7)L/min(p<0.01)。
  • 干预结束时前负荷可复性每搏功REBOA组111.2(102.5-148.6)和EVAC组116.7(116.6-141.4)均高于对照组67.1(62.7-87.9)(p=0.02和p<0.01),但仅EVAC组在整个实验期间维持较高水平。
  • 作者认为在失血性休克猪模型中,完全性主动脉阻断导致心肌损伤,EVAC减轻了心脏损伤并改善了复苏和重症监护期间的心脏性能。

适用人群与场景

  • 18只麻醉猪,经历控制性25%血容量失血,随机分入Zone 1 REBOA组、Zone 1 EVAC组或无干预对照组,干预45分钟后用失血回输复苏并观察至总共6小时实验时间。

处置流程与药物剂量

  • Zone 1 REBOA组:完全性主动脉阻断45分钟。
  • Zone 1 EVAC组:部分血流主动脉控制45分钟。
  • 对照组:无主动脉干预。
  • 三组均在45分钟干预后用失血回输复苏,随后进行重症监护观察至6小时。

研究设计与关键结果

  • 研究类型:动物实验,18只麻醉猪随机分为Zone 1 REBOA组、Zone 1 EVAC组和对照组,每组6只。
  • 干预期间平均心输出量:REBOA组9.3(8.6-15.4)L/min vs. EVAC组7.2(5.8-8.0)L/min(p=0.01)vs. 对照组6.8(5.8-7.7)L/min(p<0.01)。
  • 干预结束时前负荷可复性每搏功:REBOA组111.2(102.5-148.6)和EVAC组116.7(116.6-141.4)均高于对照组67.1(62.7-87.9)(p=0.02和p<0.01);EVAC组在整个实验期间维持较高水平,REBOA组未维持。
  • 6小时后血清肌钙蛋白:REBOA组6.26 ± 5.35 ng/mL vs. EVAC组0.92 ± 0.61 ng/mL(p=0.05)vs. 对照组0.65 ± 0.38 ng/mL(p=0.03)。
  • 心肌壁内出血:REBOA组1.67 ± 0.46 vs. 对照组0.17 ± 0.18(p=0.03);EVAC组与对照组之间无显著差异。
  • 结论:完全性主动脉阻断导致心肌损伤,但心脏功能无直接下降;EVAC减轻了心脏损伤并改善了复苏和重症监护期间的心脏性能。

证据类型、等级与局限

  • 证据类型:动物实验(猪失血性休克模型)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为在失血性休克猪模型中,完全性主动脉阻断导致心肌损伤,EVAC减轻了心脏损伤并改善了复苏和重症监护期间的心脏性能。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The cardiac effects of resuscitative endovascular balloon occlusion of the aorta (REBOA) are largely unknown. We hypothesized that increased afterload from REBOA would lead to cardiac injury, and that partial flow using endovascular variable aortic control (EVAC) would mitigate this injury.

METHODS: Eighteen anesthetized swine underwent controlled 25% blood volume hemorrhage. Animals were randomized to either Zone 1 REBOA, Zone 1 EVAC, or no intervention (control) for 45 minutes. Animals were then resuscitated with shed blood, observed during critical care, and euthanized after a 6-hour total experimental time. Left ventricular function was measured with a pressure-volume catheter, and blood samples were drawn at routine intervals.

RESULTS: The average cardiac output during the intervention period was higher in the REBOA group (9.3 [8.6-15.4] L/min) compared with the EVAC group (7.2 [5.8-8.0] L/min, p = 0.01) and the control group (6.8 [5.8-7.7] L/min, p < 0.01). At the end of the intervention, the preload recruitable stroke work was significantly higher in both the REBOA and EVAC groups compared with the control group (111.2 [102.5-148.6] and 116.7 [116.6-141.4] vs. 67.1 [62.7-87.9], p = 0.02 and p < 0.01, respectively). The higher preload recruitable stroke work was maintained throughout the experiment in the EVAC group, but not in the REBOA group. Serum troponin concentrations after 6 hours were higher in the REBOA group compared with both the EVAC and control groups (6.26 ± 5.35 ng/mL vs 0.92 ± 0.61 ng/mL and 0.65 ± 0.38 ng/mL, p = 0.05 and p = 0.03, respectively). Cardiac intramural hemorrhage was higher in the REBOA group compared with the control group (1.67 ± 0.46 vs. 0.17 ± 0.18, p = 0.03), but not between the EVAC and control groups.

CONCLUSION: In a swine model of hemorrhagic shock, complete aortic occlusion resulted in cardiac injury, although there was no direct decrease in cardiac function. EVAC mitigated the cardiac injury and improved cardiac performance during resuscitation and critical care.

来源:J Trauma Acute Care Surg,查看原文。版权归原作者所有。

参考来源

  1. Beyer CA, Hoareau GL, Tibbits EM, et al. Resuscitative endovascular balloon occlusion of the aorta induced myocardial injury is mitigated by endovascular variable aortic control. J Trauma Acute Care Surg. 2019. PMID: 31145381. doi:10.1097/TA.0000000000002363

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。