推导识别需要急诊脑CT的癫痫持续状态患者的临床决策工具
本研究为回顾性病历回顾,纳入2010至2018年急诊就诊的癫痫持续状态患者214例,排除首次发作患者。预先定义高危标准(已知恶性肿瘤、创伤、免疫抑制)及脑CT阳性发现(如颅内出血、占位)。181例无高危标准者中3%脑CT阳性,33例有高危标准者中10%脑CT阳性。初始临床决策工具敏感度38%、特异度85%、阳性预测值9%、阴性预测值97%;加入既往颅内出血标准后漏诊率降至0.6%;修改为既往颅内出血、恶性肿瘤、免疫抑制、创伤四项标准后,敏感度87.5%、特异度87.4%、阳性预测值21.2%、阴性预测值99.5%。作者认为该工具可暂缓绝大多数已知癫痫病史的癫痫持续状态患者的CT扫描,但采用前需前瞻性验证。
要点
- 已知癫痫病史的癫痫持续状态患者中,无高危标准者脑CT阳性率3%,有高危标准者10%。
- 四项标准(既往颅内出血、恶性肿瘤、免疫抑制、创伤)的临床决策工具敏感度87.5%、特异度87.4%、阴性预测值99.5%。
- 初始三项高危标准(恶性肿瘤、创伤、免疫抑制)工具敏感度仅38%,阴性预测值97%。
- 加入既往颅内出血标准可将漏诊率降至0.6%。
- 作者认为该工具可暂缓绝大多数已知癫痫病史的癫痫持续状态患者的CT扫描,但采用前需前瞻性验证。
适用人群与场景
- 2010至2018年就诊于急诊的癫痫持续状态患者,排除首次癫痫发作患者。
诊断标准与关键阈值
- 高危标准:已知恶性肿瘤、创伤、免疫抑制。
- 脑CT阳性发现包括颅内出血和占位。
- 修改后的临床决策工具标准:1)既往颅内出血,2)恶性肿瘤,3)免疫抑制,4)创伤。
研究设计与关键结果
- 回顾性病历回顾,纳入214例符合标准的癫痫持续状态患者。
- 181例无高危标准者中3%脑CT阳性;33例有高危标准者中10%脑CT阳性。
- 初始临床决策工具敏感度38%、特异度85%、阳性预测值9%、阴性预测值97%。
- 加入既往颅内出血标准后漏诊率降至0.6%。
- 修改为四项标准后敏感度87.5%、特异度87.4%、阳性预测值21.2%、阴性预测值99.5%。
证据类型、等级与局限
- 证据类型:回顾性病历回顾。
- 局限:作者指出该临床决策工具在采用前需前瞻性验证。
对床旁实践的改变
- 作者认为,使用四项标准识别高危患者,可暂缓绝大多数已知癫痫病史的癫痫持续状态患者的CT扫描。
- 作者指出该临床决策工具在采用前需前瞻性验证。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Studies have shown the value of CT brain imaging in adults with first-time seizures, but there are no recommendations regarding emergent brain CTs in persons with an established seizure disorders. Our study aimed to derive a clinical decision instrument (CDI) to determine which patients with status epilepticus (SE) require emergent brain imaging.
METHODS: This was a retrospective chart review of patients who presented to our emergency department with SE between 2010 and 2018. Patients with first-time seizures were excluded. A priori, we defined high risk criteria for emergent imaging as well as positive findings on brain CT. High risk criteria included known malignancy, trauma, and immunosuppression. Positive CT scans included findings such as intracranial hemorrhage (ICH) and mass.
RESULTS: We identified 214 patients who met inclusion criteria Of the 181 patients without high risk criteria, 3% had positive CT scans. Of the 33 patients with high risk criteria, 10% had positive CT scans. The sensitivity, specificity, PPV, and NPV for our initial CDI were 38%, 85%, 9%, and 97%. Adding the criterion of prior ICH would have lowered our miss rate to 0.6%. Modifying our CDI to 1) History of ICH, 2) Malignancy, 3) Immunosuppression, and 4) Trauma would result in a CDI with sensitivity, specificity, PPV, and NPV of 87.5%, 87.4%, 21.2%, and 99.5%.
CONCLUSIONS: By using four criteria to identify high risk patients, we can defer CT scanning in the vast majority of patients with SE and known seizure disorders. This CDI should be prospectively validated before adoption.
参考来源
- Isenberg DL, Lin A, Kairys N, et al. Derivation of a clinical decision instrument to identify patients with status epilepticus who require emergent brain CT. Am J Emerg Med. 2019. PMID: 31079976. doi:10.1016/j.ajem.2019.05.004
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。