文献速递心脑血管急症

基于脑电图的功率谱可在心脏骤停后24小时内预测昏迷结局

Electroencephalography-based power spectra allow coma outcome prediction within 24 h of cardiac arrest.
PubMed 文献 · Resuscitation · 2019-05-25
一句话结论心脏骤停后昏迷首日,脑电图功率谱在约10Hz的低功率谱值对不良结局高度特异,联合反应性可提高准确性。

该研究在瑞士四个医院站点纳入138例心脏骤停后昏迷患者,在昏迷第一天采集脑电图,根据三个月内最佳状态将结局分为有利或不利,数据分为训练集和测试集。训练集中有利与不利结局的功率谱在5.2-13.2 Hz和21 Hz以上存在显著差异,基于5.2-13.2 Hz功率的结局预测在训练集和测试集中均准确。功率谱预测结局的最大特异性和阳性预测值均为1.00(95%CI分别为0.94-1.00和0.89-1.00),功率谱联合反应性的准确性和敏感性(0.81,95%CI:0.71-0.89)优于单独基于功率谱的预测。作者认为,心脏骤停后昏迷第一天约10 Hz的低功率谱值与皮质-丘脑结构连接受损相关,对不良结局高度特异,该频率范围内的峰值可预测长期结局。

要点

  • 138例心脏骤停后昏迷患者昏迷首日脑电图显示,有利与不利结局的功率谱在5.2-13.2 Hz和21 Hz以上存在显著差异。
  • 基于5.2-13.2 Hz功率的结局预测在训练集和测试集中均准确。
  • 功率谱预测结局的最大特异性为1.00(95%CI:0.94-1.00),阳性预测值为1.00(95%CI:0.89-1.00)。
  • 功率谱联合反应性的准确性和敏感性为0.81(95%CI:0.71-0.89),优于单独基于功率谱的预测。
  • 约10 Hz的低功率谱值与不良结局高度特异相关,该频率范围内的峰值可预测长期结局。

适用人群与场景

  • 心脏骤停后昏迷患者(n=138),在昏迷第一天采集脑电图,来自瑞士四个医院站点。

研究设计与关键结果

  • 研究类型为在瑞士四个医院站点开展的脑电图功率谱预测研究,纳入138例心脏骤停后昏迷患者,昏迷第一天采集脑电图,随访三个月,结局分为有利或不利。
  • 138例中80例结局有利;训练集中有利与不利结局的功率谱在5.2-13.2 Hz和21 Hz以上存在显著差异。
  • 基于5.2-13.2 Hz功率的结局预测在训练集和测试集中均准确。
  • 功率谱预测结局的最大特异性为1.00(95%CI:0.94-1.00),阳性预测值为1.00(95%CI:0.89-1.00)。
  • 功率谱联合反应性的准确性和敏感性为0.81(95%CI:0.71-0.89),优于单独基于功率谱的预测。

证据类型、等级与局限

  • 证据类型:研究论文(脑电图功率谱预测研究),原文未报告证据等级。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,心脏骤停后昏迷第一天约10 Hz的低功率谱值与皮质-丘脑结构连接受损相关,对不良结局高度特异,该频率范围内的峰值可预测长期结局。
  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Outcome prediction in comatose patients following cardiac arrest remains challenging. Here, we assess the predictive performance of electroencephalography-based power spectra within 24 h from coma onset.

METHODS: We acquired electroencephalography (EEG) from comatose patients (n = 138) on the first day of coma in four hospital sites in Switzerland. Outcome was categorised as favourable or unfavourable based on the best state within three months. Data were split in training and test sets. We evaluated the predictive performance of EEG power spectra for long term outcome and its added value to standard clinical tests.

RESULTS: Out of 138 patients, 80 had a favourable outcome. Power spectra comparison between favourable and unfavourable outcome in the training set yielded significant differences at 5.2-13.2 Hz and above 21 Hz. Outcome prediction based on power at 5.2-13.2 Hz was accurate in training and test sets. Overall, power spectra predicted patients' outcome with maximum specificity and positive predictive value: 1.00 (95% with CI: 0.94-1.00 and 0.89-1.00, respectively). The combination of power spectra and reactivity yielded better accuracy and sensitivity (0.81, 95% CI: 0.71-0.89) than prediction based on power spectra alone.

CONCLUSIONS: On the first day of coma following cardiac arrest, low power spectra values around 10 Hz, typically linked to impaired cortico-thalamic structural connections, are highly specific of unfavourable outcome. Peaks in this frequency range can predict long-term outcome.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Kustermann T, Nguepnjo Nguissi NA, Pfeiffer C, et al. Electroencephalography-based power spectra allow coma outcome prediction within 24 h of cardiac arrest. Resuscitation. 2019. PMID: 31136808. doi:10.1016/j.resuscitation.2019.05.021

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。