文献速递复苏、休克与脓毒症呼吸衰竭与机械通气

通气与院外心脏骤停结局的关联

Association of ventilation with outcomes from out-of-hospital cardiac arrest.
PubMed 文献 · Resuscitation · 2019-05-18
一句话结论在30:2心肺复苏中,≥50%按压暂停出现肺通气波形与更高的自主循环恢复率和出院生存率相关。

本研究为回顾性观察研究,纳入2012年4月至2015年7月达拉斯-沃斯堡地区Resuscitation Outcomes Consortium持续或间断胸外按压试验中的560例院外心脏骤停患者,通过除颤电极板生物阻抗检测按压间歇的通气(肺充气)波形。患者按通气波形出现的暂停比例分为两组:<50%组(组1,N=424)与≥50%组(组2,N=136)。组2任何时间自主循环恢复率35% vs 组1 23%(p<0.005)、院前自主循环恢复率19.8% vs 8.7%(p<0.0009)、急诊科自主循环恢复率33% vs 21%(p<0.005)、出院生存率10.3% vs 4.0%(p=0.008)均更高。作者认为30:2心肺复苏中肺通气实际发生频率低,≥50%暂停出现通气与更好的复苏结局相关。

要点

  • 在30:2心肺复苏中,生物阻抗检测到的肺通气波形出现频率低:组1(<50%暂停有通气)中位11次暂停仅3次通气,组2(≥50%暂停有通气)中位12次暂停8次通气。
  • ≥50%按压暂停出现通气波形者任何时间自主循环恢复率35% vs <50%组23%(p<0.005)。
  • ≥50%按压暂停出现通气波形者院前自主循环恢复率19.8% vs 8.7%(p<0.0009),急诊科自主循环恢复率33% vs 21%(p<0.005)。
  • ≥50%按压暂停出现通气波形者出院生存率10.3% vs 4.0%(p=0.008)。
  • 本研究为回顾性观察研究,作者结论为通气在≥50%暂停出现与自主循环恢复率和生存率改善相关。

适用人群与场景

  • ≥18岁、推测心源性病因的院外心脏骤停患者,被分配至间断30:2胸外按压并球囊-面罩通气,且有≥2分钟心肺复苏记录。
  • 数据来自达拉斯-沃斯堡地区Resuscitation Outcomes Consortium持续或间断胸外按压试验,2012年4月至2015年7月。

诊断标准与关键阈值

  • 通过除颤电极板记录胸外按压段间暂停中的生物阻抗通气(肺充气)波形。
  • 按通气波形出现的暂停比例分组:<50%暂停有波形为组1,≥50%暂停有波形为组2。

研究设计与关键结果

  • 回顾性观察研究,纳入560例院外心脏骤停患者,比较通气波形出现<50%暂停(组1,N=424)与≥50%暂停(组2,N=136)的结局。
  • 30:2心肺复苏平均持续时间13±7分钟,共7762次胸外按压暂停。
  • 组1中位11次暂停、3次通气/人;组2中位12次暂停、8次通气/人。
  • 任何时间自主循环恢复:组2 35% vs 组1 23%(p<0.005)。
  • 院前自主循环恢复:组2 19.8% vs 组1 8.7%(p<0.0009)。
  • 急诊科自主循环恢复:组2 33% vs 组1 21%(p<0.005)。
  • 出院生存率:组2 10.3% vs 组1 4.0%(p=0.008)。

证据类型、等级与局限

  • 证据类型:回顾性观察研究。
  • 作者结论:本新型研究显示30:2心肺复苏中肺通气发生频率低,≥50%暂停出现通气与自主循环恢复率和生存率显著改善相关。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 本研究提示在30:2心肺复苏中,生物阻抗检测到的肺通气实际发生频率低(组1中位3次通气/人,组2中位8次通气/人)。
  • 本观察性研究显示,≥50%按压暂停出现通气波形与更高的任何时间自主循环恢复率(35% vs 23%)、院前自主循环恢复率(19.8% vs 8.7%)、急诊科自主循环恢复率(33% vs 21%)和出院生存率(10.3% vs 4.0%)相关。
  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM OF STUDY: To determine the association between bioimpedence-detected ventilation and out-of-hospital cardiac arrest (OHCA) outcomes.

METHODS: This is a retrospective, observational study of 560 OHCA patients from the Dallas-Fort Worth site enrolled in the Resuscitation Outcomes Consortium Trial of Continuous or Interrupted Chest Compressions During CPR from 4/2012 to 7/2015. We measured bioimpedance ventilation (lung inflation) waveforms in the pause between chest compression segments (Physio-Control LIFEPAK 12 and 15, Redmond, WA) recorded through defibrillation pads. We included cases ≥18 years with presumed cardiac cause of arrest assigned to interrupted 30:2 chest compressions with bag-valve-mask ventilation and ≥2 min of recorded cardiopulmonary resuscitation. We compared outcomes in two a priori pre-specified groups: patients with ventilation waveforms in <50% of pauses (Group 1) versus those with waveforms in ≥50% of pauses (Group 2).

RESULTS: Mean duration of 30:2 CPR was 13 ± 7 min with a total of 7762 pauses in chest compressions. Group 1 (N = 424) had a median 11 pauses and 3 ventilations per patient vs. Group 2 (N = 136) with a median 12 pauses and 8 ventilations per patient, which was associated with improved return of spontaneous circulation (ROSC) at any time (35% vs. 23%, p < 0.005), prehospital ROSC (19.8% vs. 8.7%, p < 0.0009), emergency department ROSC (33% vs. 21%, p < 0.005), and survival to hospital discharge (10.3% vs. 4.0%, p = 0.008).

CONCLUSIONS: This novel study shows that ventilation with lung inflation occurs infrequently during 30:2 CPR. Ventilation in ≥50% of pauses was associated with significantly improved rates of ROSC and survival.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Chang MP, Lu Y, Leroux B, et al. Association of ventilation with outcomes from out-of-hospital cardiac arrest. Resuscitation. 2019. PMID: 31112744. doi:10.1016/j.resuscitation.2019.05.006

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。