文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

聚乙二醇-20k急性复苏的血栓弹力图分析

Acute resuscitation with polyethylene glycol-20k: A thromboelastographic analysis.
PubMed 文献 · J Trauma Acute Care Surg · 2019-01-01
一句话结论猪失血性休克模型中,聚乙二醇-20k低容量复苏使存活时间延长2.6倍,但降低血栓弹力图最大振幅、抑制血小板功能。

该研究在猪失血性休克模型中比较10%聚乙二醇-20k溶液与乳酸林格液低容量复苏对凝血和血小板功能的影响。出血至乳酸达7 mmol/L或失血50%至55%估计血容量后开腹模拟组织损伤,两组均按估计血容量10%的体积复苏。聚乙二醇-20k组存活时间较对照组延长2.6倍(p<0.001),血浆容量显著增加;但血栓弹力图最大振幅主要下降,240分钟时趋向基线。结论认为聚乙二醇-20k急性复苏改善对低血容量的耐受,同时部分因其扩容效应而降低凝血级联中的血小板功能。

要点

  • 猪失血性休克模型中,聚乙二醇-20k低容量复苏组存活时间较乳酸林格液对照组延长2.6倍(p<0.001)。
  • 聚乙二醇-20k组所有猪存活240分钟并随后安乐死,血压和乳酸正常;乳酸林格液组复苏后平均90分钟死于低血压。
  • 聚乙二醇-20k主要降低血栓弹力图最大振幅,但240分钟时开始趋向基线。
  • 聚乙二醇-20k低容量复苏后血浆峰值浓度为5.7 mg/mL,比简单稀释预测的10 mg/mL低40%,半衰期59.6分钟。
  • 血红蛋白持续下降提示聚乙二醇-20k组血浆容量显著增加。

适用人群与场景

  • 麻醉猪,经控制性出血至乳酸达7 mmol/L或失血达估计血容量的50%至55%,并开腹模拟组织损伤。

处置流程与药物剂量

  • 低容量复苏使用异硫氰酸荧光素标记的10%聚乙二醇-20k溶液(100 mg/mL)或乳酸林格液,两组输注体积均为估计血容量的10%(每组n=5)。
  • 在外科手术后(基线)、出血后及复苏后15分钟、120分钟、240分钟行血栓弹力图检测。

研究设计与关键结果

  • 研究类型为猪失血性休克模型,每组n=5;聚乙二醇-20k组存活时间较对照组延长2.6倍(p<0.001)。
  • 乳酸林格液组复苏后平均90分钟死于低血压;聚乙二醇-20k组全部存活240分钟,随后安乐死时血压和乳酸正常。
  • 聚乙二醇-20k组血红蛋白持续下降,提示血浆容量显著增加。
  • 聚乙二醇-20k主要降低血栓弹力图最大振幅,但240分钟时开始趋向基线。
  • 聚乙二醇-20k低容量复苏后血浆峰值浓度为5.7 mg/mL,比简单稀释预测的10 mg/mL低40%,半衰期为59.6分钟。

证据类型、等级与局限

  • 证据类型:动物实验(猪失血性休克模型)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,聚乙二醇-20k急性复苏显著改善对低血容量的耐受,但也降低凝血级联中的血小板功能,部分归因于其扩容效应。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Previous ex vivo studies have shown that polyethylene glycol-20,000 Da (PEG-20k), a novel synthetic polymer that is highly effective for resuscitation, has a hypocoagulable effect on human blood. This study's objective was to determine the in vivo effects of PEG-20k-based resuscitation solutions on coagulation and platelet function in a porcine model of hemorrhagic shock.

METHODS: Anesthetized pigs underwent controlled hemorrhage until the lactate reached 7 mmol/L or 50% to 55% of their estimated blood volume was removed. A laparotomy was performed to simulate tissue injury. Low volume resuscitation (LVR) was given with fluorescein isothiocyanate-labeled 10% PEG-20k solution (100 mg/mL) or Lactated Ringers, both delivered at volumes equal to 10% of the estimated blood volume (n = 5). Thromboelastography was performed after surgery (baseline), after hemorrhage, and 15 minutes, 120 minutes, and 240 minutes postresuscitation. Hemoglobin was measured to determine changes in plasma volume. Plasma PEG-20k concentration was measured by indicator dilution.

RESULTS: Pigs given PEG-20k survived 2.6-fold longer than controls (p < 0.001) and had a significant increase in plasma volume demonstrated by the sustained drop in hemoglobin, relative to controls. Pigs resuscitated with LR died from hypotension an average of 90 minutes after resuscitation compared to the PEG-20k pigs, which all survived 240 minutes and were then euthanized with normal blood pressure and lactate. Administration of PEG-20k primarily decreased the thromboelastograph maximum amplitude, however this began to return toward baseline by 240 minutes. Peak plasma concentration of PEG-20k after LVR were 40% lower than predicted, based on simple dilution (5.7 mg/mL vs. 10 mg/mL) and the half-life was 59.6 minutes.

CONCLUSION: These data demonstrate that acute resuscitation with PEG-20k significantly improves tolerance to hypovolemia but also decreases platelet function in the coagulation cascade, which was due, in part, to its volume expanding effects.

来源:J Trauma Acute Care Surg,查看原文。版权归原作者所有。

参考来源

  1. Wickramaratne N, Kenning K, Reichstetter H, et al. Acute resuscitation with polyethylene glycol-20k: A thromboelastographic analysis. J Trauma Acute Care Surg. 2019. PMID: 31033892. doi:10.1097/TA.0000000000002332

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。