虚拟现实心肺复苏培训移动应用与标准移动应用对旁观者反应影响的随机对照研究
该随机对照研究将105名非专业旁观者分为虚拟现实移动应用组(52人)和标准移动应用组(53人),在干预后技能测试中收集旁观者反应数据及心肺复苏质量。虚拟现实组拨打911(82% vs 58%,p=0.007)和索要自动体外除颤器(57% vs 28%,p=0.003)的比例显著更高,但实施心肺复苏(98% vs 98%)和应用自动体外除颤器(90% vs 93%)无差异。胸外按压频率两组无显著差异(104±42次/分 vs 112±30次/分),胸外按压深度虚拟现实组较低(38±15毫米 vs 44±13毫米,p=0.05)。
要点
- 虚拟现实移动应用组拨打911的比例为82%,显著高于标准移动应用组的58%(p=0.007)。
- 虚拟现实移动应用组索要自动体外除颤器的比例为57%,显著高于标准移动应用组的28%(p=0.003)。
- 两组实施心肺复苏的比例均为98%,应用自动体外除颤器的比例分别为90%和93%,无显著差异。
- 虚拟现实移动应用组胸外按压深度为38±15毫米,低于标准移动应用组的44±13毫米(p=0.05)。
- 两组胸外按压频率分别为104±42次/分和112±30次/分,无显著差异。
适用人群与场景
- 非专业旁观者,平均年龄46±16岁,34%为女性,59%为黑人,17%目前接受过心肺复苏培训(≤2年)。
研究设计与关键结果
- 随机对照研究,2018年3月至2018年9月纳入105名受试者:虚拟现实移动应用组52人,标准移动应用组53人。
- 旁观者反应:拨打911虚拟现实组82% vs 标准组58%(p=0.007);索要自动体外除颤器虚拟现实组57% vs 标准组28%(p=0.003)。
- 实施心肺复苏虚拟现实组98% vs 标准组98%(p=NS);应用自动体外除颤器虚拟现实组90% vs 标准组93%(p=NS)。
- 胸外按压频率虚拟现实组104±42次/分 vs 标准组112±30次/分(p=NS);胸外按压深度虚拟现实组38±15毫米 vs 标准组44±13毫米(p=0.05)。
证据类型、等级与局限
- 证据类型:随机对照研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,使用虚拟现实移动应用显著增加了拨打911和索要自动体外除颤器的可能性,但胸外按压深度降低。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Using a mobile virtual reality (VR) platform to heighten realism for cardiopulmonary resuscitation (CPR) training has the potential to improve bystander response.
OBJECTIVES: We examined whether using a VR mobile application (mApp) for CPR training would improve bystander response compared with a standard mApp CPR training.
METHODS: We randomized lay bystanders to either our intervention arm (VR mApp) or our control arm (mApp). During a post-intervention skills test, we collected bystander response data (call 911, perform CPR, ask for an automated external defibrillator (AED)), along with CPR quality (chest compression (CC) rate and depth). Wilcox rank sum was used to analyze CC rate and CC depth as they were not normally distributed; Pearson's Chi-square was used to analyze Chain of Survival variables.
RESULTS: Between 3/2018 and 9/2018, 105 subjects were enrolled: 52 VR mApp and 53 mApp. Mean age was 46 ± 16 years, 34% were female, 59% were Black, and 17% were currently CPR trained (≤2 years). Bystander response was significantly higher in the VR mApp arm: called 911 (82% vs 58%, p = 0.007) and asked for an AED (57% vs 28%, p = 0.003). However there was no difference in CPR performed (98% vs 98%, p = NS) and the application of the AED (90% vs 93%, p = NS). When comparing the VR mApp to the mApp, mean CC rate was 104 ± 42 cpm vs 112 ± 30 cpm (p = NS), and mean CC depth was 38 ± 15 mm vs 44 ± 13 mm (p = 0.05).
CONCLUSION: The use of the VR mApp significantly increased the likelihood of calling 911 and asking for an AED, however, CC depth was decreased.
参考来源
- Leary M, McGovern SK, Chaudhary Z, et al. Comparing bystander response to a sudden cardiac arrest using a virtual reality CPR training mobile app versus a standard CPR training mobile app. Resuscitation. 2019. PMID: 31005588. doi:10.1016/j.resuscitation.2019.04.017
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。