肺超声可诊断撤机诱发的心源性肺水肿
该前瞻性研究在42例患者共62次自主呼吸试验前后,于四个前胸壁位点行肺超声并计数B线。撤机诱发肺水肿(WIPO)由对肺超声设盲的专家判定为参考标准。在33次自主呼吸试验失败者中,B线较基线增加≥6条诊断WIPO的敏感度88%(64-98)、特异度88%(62-98),曲线下面积0.91(0.75-0.98)。作者认为该指标可诊断WIPO,但需在更大样本中确认。
要点
- 在自主呼吸试验失败者中,B线较基线增加≥6条诊断WIPO的敏感度88%(64-98)、特异度88%(62-98)。
- WIPO 17例全部出现在自主呼吸试验失败的33例中,其中15例B线较基线增加≥6条(13例增加≥8条)。
- 自主呼吸试验失败但无WIPO的16例中,仅2例B线较基线增加≥6条。
- 自主呼吸试验成功的29例中,2例B线较基线增加≥6条。
- 肺超声在四个前胸壁位点于自主呼吸试验前后计数B线,参考诊断由对肺超声设盲的专家判定。
适用人群与场景
- 在42例患者共62次自主呼吸试验中评估,自主呼吸试验前和结束时行肺超声。
诊断标准与关键阈值
- B线较基线增加≥6条(Delta-B-lines≥6)为诊断WIPO的最佳阈值,在四个前胸壁位点计数B线。
研究设计与关键结果
- 研究类型为前瞻性研究,42例患者共62次自主呼吸试验,自主呼吸试验失败33次。
- WIPO发生于17例,且全部为自主呼吸试验失败者。
- 在自主呼吸试验失败者中,Delta-B-lines≥6诊断WIPO的敏感度88%(64-98)、特异度88%(62-98),曲线下面积0.91(0.75-0.98)。
证据类型、等级与局限
- 证据类型:前瞻性研究。
- 局限:原文结论指出该结果需在更大样本中确认。
对床旁实践的改变
- 作者认为,四个前胸壁位点B线较基线增加≥6条可诊断WIPO,但需在更大样本中确认。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
RATIONALE: Detecting weaning-induced pulmonary oedema (WIPO) is important because its treatment might prompt extubation. For this purpose, lung ultrasound might be an attractive tool, since it demonstrates pulmonary oedema through the appearance of B-lines.
OBJECTIVES: To test the ideal profile (increase in the number of B-lines) for diagnosing WIPO.
METHODS: Before and at the end of 62 spontaneous breathing trials (SBT) performed in 42 patients, we prospectively assessed lung ultrasound on four anterior chest wall points. B-lines were counted before and at the end of SBT. We looked for the threshold of B-line increase (Delta-B-lines) that provided the best diagnostic accuracy, compared to the reference diagnosis of WIPO established by experts blinded to lung ultrasound.
RESULTS: SBT failed in 33 cases. WIPO occurred in 17 cases and all failed. The best diagnostic accuracy was reached with a Delta-B-lines ≥ 6. Among WIPO, the number of B-lines increased by ≥ 6 in 15 cases (including 13 cases with an increase of ≥ 8 B-lines). Among the 16 cases with SBT failure but without WIPO, the Delta-B-lines was ≥ 6 in two cases. Among the 33 cases with SBT failure, this profile diagnosed WIPO with a sensitivity of 88% (64-98) and a specificity of 88% (62-98) [area under the receiver operating characteristic curve 0.91 (0.75-0.98)]. Among the 29 cases with SBT success, a Delta-B-lines ≥ 6 occurred in two cases.
CONCLUSIONS: This study suggests that a Delta-B-lines ≥ 6 on four anterior points allows the diagnosis of WIPO with the best accuracy. This should be confirmed in larger populations.
参考来源
- Ferré A, Guillot M, Lichtenstein D, et al. Lung ultrasound allows the diagnosis of weaning-induced pulmonary oedema. Intensive Care Med. 2019. PMID: 30863935. doi:10.1007/s00134-019-05573-6