文献速递复苏、休克与脓毒症心脑血管急症

床旁超声脉搏检查:一项比较触诊与床旁超声检测脉搏的随机对照交叉研究

The POCUS pulse check: A randomized controlled crossover study comparing pulse detection by palpation versus by point-of-care ultrasound.
PubMed 文献 · Resuscitation · 2019-03-20
一句话结论在活体受试者中,床旁超声检测颈动脉脉搏不慢于触诊,首次尝试成功率更高,测量时间变异更小。

本研究为前瞻性随机对照交叉非劣效性试验,纳入111名医护人员,在15分钟聚焦超声工作坊后,对两名不同受试者随机顺序分别用床旁超声和触诊检测颈动脉脉搏。主要终点为脉搏检测时间,超声组平均4.22秒(标准差3.26)vs 触诊组4.71秒(标准差6.45),平均差-0.49秒(90%CI:-1.77至0.39),达到非劣效。超声组首次尝试成功率99.1% vs 触诊组85.6%(p=0.0001),脉搏检查超过5秒或10秒的比例两组无显著差异。研究结论为在活体受试者中超声检测颈动脉脉搏不慢于触诊,首次尝试成功率更高且测量时间变异更小,简短教学即可提升信心,为后续心脏骤停患者研究提供基础。

要点

  • 在活体受试者中,床旁超声检测颈动脉脉搏平均用时4.22秒(标准差3.26),触诊为4.71秒(标准差6.45),平均差-0.49秒(90%CI:-1.77至0.39),达到非劣效。
  • 超声组首次尝试检测脉搏成功率99.1%,显著高于触诊组的85.6%(p=0.0001)。
  • 脉搏检查时间超过5秒的比例超声组23% vs 触诊组19%(p=0.45),超过10秒的比例9% vs 8%(p=0.81),均无显著差异。
  • 研究前医护人员对触诊的信心高于超声(68 mm vs 15 mm,p<0.001),研究后对超声的信心高于触诊(91 mm vs 83 mm,p<0.001)。
  • 15分钟聚焦超声工作坊足以提升颈动脉脉搏识别的信心,包括既往无超声培训者。

适用人群与场景

  • 医护人员(HCPs),包括既往无超声培训者,在活体受试者上进行脉搏检测。
  • 研究场景为模拟教学环境,非心脏骤停患者;结论仅适用于活体受试者。

处置流程与药物剂量

  • 医护人员参加15分钟聚焦超声工作坊,学习使用B型超声识别颈动脉脉搏。
  • 对每名参与者按随机顺序在两名不同受试者上分别进行床旁超声和传统触诊脉搏检查并计时。

研究设计与关键结果

  • 前瞻性随机对照交叉非劣效性试验,111名医护人员完成研究,主要终点为颈动脉脉搏检测时间(秒)。
  • 超声组平均脉搏检测时间4.22秒(标准差3.26)vs 触诊组4.71秒(标准差6.45),平均差-0.49秒(90%CI:-1.77至0.39),达到非劣效(非劣效界值为2秒)。
  • 脉搏检查超过5秒的比例:超声组23% vs 触诊组19%(p=0.45);超过10秒的比例:超声组9% vs 触诊组8%(p=0.81),均无显著差异。
  • 首次尝试检测脉搏成功率:超声组99.1% vs 触诊组85.6%(p=0.0001)。
  • 研究前信心(100 mm视觉模拟量表):触诊68 mm(四分位距48-83)vs 超声15 mm(四分位距8-42)(p<0.001);研究后信心:超声91 mm(四分位距82-97)vs 触诊83 mm(四分位距72-94)(p<0.001)。

证据类型、等级与局限

  • 证据类型:前瞻性随机对照交叉非劣效性试验。
  • 研究设计效能设定为判断超声脉搏检查是否不慢于触诊超过2秒。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在活体受试者中,床旁超声检测颈动脉脉搏不慢于触诊,首次尝试成功率更高且测量时间变异更小。
  • 作者认为,简短教学课程足以提升颈动脉脉搏识别的信心,即使既往无超声培训者。
  • 作者指出,本研究初步结果为更大规模研究评估该方法在心脏骤停患者中的应用提供基础。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Manual pulse checks (MP) are an unreliable skill even in the hands of healthcare providers (HCPs). In the context of cardiac arrest, this may translate into inappropriate chest compressions when a pulse is present, or conversely omitting chest compressions when one is absent. To date, no study has assessed the use of B-mode ultrasound (US) for the detection of a carotid pulse. The primary objective of this study was to assess the time required to detect a carotid pulse in live subjects using US compared to the traditional palpation method.

METHODS: We conducted a prospective randomized controlled crossover non-inferiority trial. HCPs attended a 15 minute focused US workshop on identification of the carotid pulse. Both pulse check methods were timed for each participant on two different subjects in random order. The primary outcome was time to carotid pulse detection in seconds (s). Secondary outcomes included confidence levels of pulse detection measured on a 100 mm visual analog scale (VAS) and rates of prolonged pulse checks (> 5 s or >10 s). The study was powered to determine whether US pulse checks were not slower than MP by greater than two seconds. The results are presented as the difference in means with a 90% two-sided confidence interval (CI).

RESULTS: 111 participants completed the study. Mean pulse detection times were 4.22 s (SD 3.26) by US compared to 4.71 s (SD 6.45) by MP with a mean difference in times of -0.49 s (90% CI: -1.77 to 0.39). There were no significant differences between US and MP in the rates of prolonged pulse checks of greater than 5 s (23% vs 19%, p = 0.45) or 10 s (9% vs 8%, p = 0.81). First attempt at detection of pulse checks was more successful in the US group (99.1% vs 85.6%, p = 0.0001). Prior to training, participants reported higher confidence using MP compared to US; 68 (IQR 48-83) vs 15 (IQR 8-42) mm (p < 0.001). Following the study, participants reported higher confidence levels using US than MP; 91 (IQR 82-97) vs 83 (IQR 72-94) mm (p < 0.001).

CONCLUSIONS: Carotid pulse detection in live subjects was not slower using US as compared to palpation, and demonstrated higher first attempt success rate and less variability in measurement times. A brief teaching session was sufficient to improve confidence of carotid pulse identification even in those with no previous US training. The preliminary results from this study provide the groundwork for larger studies to evaluate this pulse check method for patients in cardiac arrest.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Badra K, Coutin A, Simard R, et al. The POCUS pulse check: A randomized controlled crossover study comparing pulse detection by palpation versus by point-of-care ultrasound. Resuscitation. 2019. PMID: 30902687. doi:10.1016/j.resuscitation.2019.03.009

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。