不同超声探头类型确认气管插管位置的准确性比较
本研究在尸体实验室使用三具不同颈围的尸体,随机进行气管或食管插管,由盲法超声操作者交替使用线阵或凸阵探头评估气管插管位置。共完成405次评估,其中气管插管198次(48.9%),食管插管207次(51.1%)。线阵探头准确性98%(95%CI 95.1%至99.2%),凸阵探头95%(95%CI 91.1%至97.3%)。线阵探头平均识别时间7.46秒(95%CI 6.23至8.7秒)显著低于凸阵探头11.63秒(95%CI 9.05至14.2秒);操作者信心线阵探头4.84/5.0(95%CI 4.76至4.91)显著高于凸阵探头4.44/5.0(95%CI 4.3至4.57)。所有操作者均偏好线阵探头。
要点
- 在尸体模型中,线阵探头确认气管插管位置的准确性为98%(95%CI 95.1%至99.2%),凸阵探头为95%(95%CI 91.1%至97.3%),两者无显著差异。
- 线阵探头平均识别时间为7.46秒(95%CI 6.23至8.7秒),显著短于凸阵探头的11.63秒(95%CI 9.05至14.2秒)。
- 线阵探头操作者信心评分为4.84/5.0(95%CI 4.76至4.91),显著高于凸阵探头的4.44/5.0(95%CI 4.3至4.57)。
- 所有操作者均偏好线阵探头而非凸阵探头。
- 作者认为需要进一步研究以确定在更多新手操作者或特定患者人群中准确性是否会变化。
适用人群与场景
- 尸体实验室中三具不同颈围的尸体,随机分为气管插管或食管插管。
研究设计与关键结果
- 研究类型为尸体实验室研究,共完成405次评估,其中气管插管198次(48.9%),食管插管207次(51.1%)。
- 线阵探头准确性98%(95%CI 95.1%至99.2%),凸阵探头准确性95%(95%CI 91.1%至97.3%),两者无显著差异。
- 线阵探头平均识别时间7.46秒(95%CI 6.23至8.7秒)显著低于凸阵探头11.63秒(95%CI 9.05至14.2秒)。
- 线阵探头平均操作者信心4.84/5.0(95%CI 4.76至4.91)显著高于凸阵探头4.44/5.0(95%CI 4.3至4.57)。
- 所有操作者均偏好线阵探头。
证据类型、等级与局限
- 证据类型为尸体实验室研究。
- 局限:作者指出需要进一步研究以确定在更多新手操作者或特定患者人群中准确性是否会变化。
对床旁实践的改变
- 作者认为需要进一步研究以确定在更多新手操作者或特定患者人群中准确性是否会变化。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
INTRODUCTION: Ultrasound has been increasingly utilized for the identification of endotracheal tube (ETT) location after an intubation attempt, particularly among patients in cardiac arrest. However, prior studies have varied with respect to the choice of transducer and no studies have directly compared the accuracy between transducer types. Our study is the first to directly compare the accuracy of ETT confirmation between the linear and curvilinear transducer.
METHODS: This study was performed in a cadaver lab using three different cadavers chosen to represent varying neck circumferences. Cadavers were randomized to tracheal or esophageal intubation. Blinded sonographers assessed the location of the ETT using either a linear or curvilinear transducer in an alternating sequence. Accuracy of sonographer identification, time to identification, and operator confidence were assessed.
RESULTS: Four hundred and five assessments were performed with 198 (48.9%) tracheal and 207 (51.1%) esophageal intubations. The linear transducer was 98% (95% CI 95.1% to 99.2%) accurate. The curvilinear transducer was 95% (95% CI 91.1% to 97.3%) accurate. The mean time to identification was significantly lower with the linear transducer [7.46 s (95% CI 6.23 to 8.7 s)] as compared with the curvilinear transducer [11.63 s (95% CI 9.05 to 14.2 s)]. The mean operator confidence was significantly higher with the linear transducer [4.84/5.0 (95% CI 4.76 to 4.91)] than with the curvilinear transducer [4.44/5.0 (95% CI 4.3 to 4.57)]. All operators preferred the linear transducer over the curvilinear transducer.
CONCLUSION: The diagnostic accuracy of ultrasound for ETT confirmation did not significantly differ between ultrasound transducer types, but the curvilinear transducer was associated with a longer time to confirmation and lower operator confidence. Further studies are needed to determine if the accuracy would change with more novice providers or in specific patient populations.
参考来源
- Gottlieb M, Holladay D, Burns K, et al. Accuracy of ultrasound for endotracheal intubation between different transducer types. Am J Emerg Med. 2019. PMID: 30890289. doi:10.1016/j.ajem.2019.03.016
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。