文献速递心脑血管急症重症综合管理与镇静镇痛

视神经鞘直径预测心脏骤停后神经预后的诊断性能:系统评价与Meta分析

Diagnostic performance of optic nerve sheath diameter for predicting neurologic outcome in post-cardiac arrest patients: A systematic review and meta-analysis.
PubMed 文献 · Resuscitation · 2019-03-13
一句话结论心脏骤停后患者中,视神经鞘直径预测不良神经预后汇总特异性0.99、敏感性0.41,AUC 0.86,作者建议优先用眼部超声测量并用于心源性心脏骤停患者。

该系统评价与Meta分析纳入8项诊断准确性研究、共766例心脏骤停后患者,评估视神经鞘直径(ONSD)预测神经预后的诊断性能,并比较眼部超声与脑CT两种测量方式。预测不良神经预后时,ONSD汇总敏感性0.41、特异性0.99、AUC 0.86,汇总诊断比值比提示有信息价值。亚组分析显示眼部超声测量较脑CT敏感性显著更高、特异性相似。作者认为ONSD可能有助于预测心脏骤停后神经预后,建议用眼部超声测量、用于心源性心脏骤停患者,并以Glasgow-Pittsburgh脑功能分级评价神经预后。

要点

  • 心脏骤停后患者用ONSD预测不良神经预后:汇总敏感性0.41、特异性0.99、AUC 0.86。
  • 汇总诊断比值比的95%CI不包含1,提示ONSD对神经预后预测有信息价值。
  • 眼部超声测量ONSD的敏感性显著高于脑CT,特异性与脑CT相似。
  • 异质性来源包括地区、恢复自主循环后至检查时间、心脏骤停病因和参考标准。
  • 作者建议用眼部超声测量ONSD、用于心源性心脏骤停患者,并以Glasgow-Pittsburgh脑功能分级评价神经预后。

适用人群与场景

  • 心脏骤停后患者,用于预测神经预后;作者建议应用于心源性心脏骤停患者。

处置流程与药物剂量

  • 作者建议测量ONSD时具体使用眼部超声,而非脑CT。
  • 作者建议以Glasgow-Pittsburgh脑功能分级(CPC)评价神经预后,以更准确预测神经预后。

研究设计与关键结果

  • 系统评价与Meta分析,纳入8项诊断准确性研究、共766例患者,检索PubMed和EMBASE。
  • 预测不良神经预后:ONSD汇总敏感性0.41、汇总特异性0.99、AUC 0.86。
  • 汇总诊断比值比的95%CI不包含1,提示ONSD对神经预后预测有信息价值。
  • 亚组分析:眼部超声测量ONSD的敏感性显著高于脑CT,特异性与脑CT相似。
  • Meta回归显示地区、恢复自主循环后至检查时间、心脏骤停病因和参考标准为异质性来源。

证据类型、等级与局限

  • 证据类型:系统评价与Meta分析(诊断准确性研究)。
  • 采用双变量模型及分层汇总受试者工作特征模型评估诊断性能,用QUADAS-2工具评估方法学质量。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为ONSD可能有助于预测心脏骤停后患者的神经预后。
  • 作者建议用眼部超声测量ONSD、用于心源性心脏骤停患者,并以Glasgow-Pittsburgh脑功能分级评价神经预后,以更准确预测神经预后。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIMS: We evaluated the diagnostic performance of optic nerve sheath diameter (ONSD) for prediction of neurologic outcome in post-cardiac arrest patients and relative prediction performance according to ONSD measurement modality.

DATA SOURCES: PubMed and EMBASE databases were searched for diagnostic accuracy studies that used ocular ultrasound or brain computed tomography (CT) for prediction of neurologic outcome. Bivariate modelling and hierarchical-summary and receiver-operating-characteristic modelling were performed to evaluate diagnostic performance. A pooled diagnostic odds ratio with a 95% confidence interval not including 1 was considered informative. Subgroup analysis was performed according to the modality (ocular US vs. brain CT). Methodologic quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. We performed meta-regression analyses for heterogeneity exploration.

RESULTS: Eight studies including 766 patients were included. For prediction of poor neurologic outcome, ONSD showed pooled sensitivity 0.41, pooled specificity 0.99, and area under the receiver-operating-characteristic curve 0.86. According to the pooled diagnostic odds ratios, ONSD was informative for prediction of neurologic outcome. In subgroup analysis, ONSD on ocular ultrasound showed significantly higher sensitivity and similar specificity than that on brain CT. On meta-regression analysis, locale, time to examination after return of spontaneous circulation, cause of cardiac arrest, and reference standard were sources of heterogeneity.

CONCLUSION: ONSD may be useful for predicting neurologic outcomes in post-cardiac arrest patients. Measuring the ONSD specifically using ocular ultrasound, application in patients with cardiac-origin cardiac arrest, and using the Glasgow-Pittsburgh Cerebral Performance Categories for neurologic outcome evaluation are recommended for more accurately predicting neurologic outcomes.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Lee SH, Jong Yun S. Diagnostic performance of optic nerve sheath diameter for predicting neurologic outcome in post-cardiac arrest patients: A systematic review and meta-analysis. Resuscitation. 2019. PMID: 30878375. doi:10.1016/j.resuscitation.2019.03.004

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。