头皮脑电图测得的肌电反应性有助于心脏骤停后预后判断
该研究基于多中心前瞻性登记中184例心脏骤停后接受早期EEG的成年昏迷患者,在EEG记录期间行听觉和躯体感觉刺激,由认证脑电图医师回顾性盲法评估EEG反应性(EEG-R)和EMG反应性(EMG-R),并与3个月时脑功能分级(CPC)比较,CPC 1-2为良好预后、CPC 3-5为不良预后。EEG-R和EMG-R均为良好预后的预测因素:EEG-R准确率72%(95%CI 66-79)、敏感度86%(78-93)、特异度60%(50-69);EMG-R准确率65%(58-72)、敏感度61%(51-75)、特异度69%(60-78)。将反应性定义为EEG-R和/或EMG-R时,准确率73%(67-70)、敏感度94%(90-99)、特异度53%(43-63)。作者认为,评估EEG反应性时纳入EMG似乎可减少识别心脏骤停后良好预后患者的假阴性预测。
要点
- 184例心脏骤停后昏迷患者早期EEG中,EEG-R预测良好预后准确率72%(95%CI 66-79)、敏感度86%(78-93)、特异度60%(50-69)。
- EMG-R预测良好预后准确率65%(58-72)、敏感度61%(51-75)、特异度69%(60-78)。
- 反应性定义为EEG-R和/或EMG-R时,敏感度升至94%(90-99),准确率73%(67-70),特异度降至53%(43-63)。
- 作者认为,评估EEG反应性时纳入EMG似乎可减少对良好预后患者的假阴性预测。
适用人群与场景
- 多中心前瞻性登记中184例心脏骤停后接受早期EEG的成年昏迷患者。
诊断标准与关键阈值
- 良好功能预后定义为3个月时CPC 1-2,不良预后定义为CPC 3-5。
- EEG记录期间行听觉和躯体感觉刺激,由认证脑电图医师回顾性视觉评估EEG反应性(EEG-R)和EMG反应性(EMG-R)。
研究设计与关键结果
- 多中心前瞻性登记中184例心脏骤停后昏迷患者,早期EEG期间行听觉和躯体感觉刺激,回顾性视觉评估EEG-R和EMG-R,与3个月CPC比较。
- EEG-R预测良好预后:准确率72%(95%CI 66-79),敏感度86%(78-93),特异度60%(50-69)。
- EMG-R预测良好预后:准确率65%(58-72),敏感度61%(51-75),特异度69%(60-78)。
- 反应性定义为EEG-R和/或EMG-R时:准确率73%(67-70),敏感度94%(90-99),特异度53%(43-63)。
证据类型、等级与局限
- 证据类型:多中心前瞻性登记研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,评估EEG反应性时纳入EMG似乎可减少识别心脏骤停后良好预后患者的假阴性预测。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
AIM: To assess whether stimulus-induced modifications of electromyographic activity observed on scalp EEG have a prognostic value in comatose patients after cardiac arrest.
METHODS: 184 adult patients from a multi-centric prospective register who underwent an early EEG after cardiac arrest were included. Auditory and somatosensory stimulation was performed during EEG-recording. EEG reactivity (EEG-R) and EMG reactivity (EMG-R) were retrospectively assessed visually by board-certified electroencephalographers, and compared with clinical outcome (cerebral performance category, CPC) at three months. A favorable functional outcome was defined as CPC 1-2, an unfavorable outcome as CPC 3-5.
RESULTS: Both EEG-R and EMG-R were predictors for good outcome (EEG-R accuracy 72% (95%-CI 66-79), sensitivity 86% (78-93), specificity 60% (50-69); EMG-R accuracy 65% (58-72), sensitivity 61% (51-75), specificity 69% (60-78)). When reactivity was defined as EEG-R and/or EMG-R, the accuracy was 73% (67-70), the sensitivity 94% (90-99), and the specificity 53% (43-63).
CONCLUSION: Taking EMG into account when assessing reactivity of EEG seems to reduce false negative predictions for identifying patients with favorable outcome after cardiac arrest.
参考来源
- Caporro M, Rossetti AO, Seiler A, et al. Electromyographic reactivity measured with scalp-EEG contributes to prognostication after cardiac arrest. Resuscitation. 2019. PMID: 30885825. doi:10.1016/j.resuscitation.2019.03.014
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。