文献速递心脑血管急症重症综合管理与镇静镇痛

神经重症监护室护士利用定量脑电图趋势面板实时检测癫痫发作的试验

A Trial of Real-Time Electrographic Seizure Detection by Neuro-ICU Nurses Using a Panel of Quantitative EEG Trends.
PubMed 文献 · Neurocrit Care · 2019-01-01
一句话结论经过个体化简短培训后,神经重症监护室护士床旁实时判读定量脑电图检测复发性非惊厥性癫痫发作,敏感度85.1%、特异度89.8%,假阳性率0.1次/小时。

该前瞻性单机构研究纳入2016至2018年杜克神经重症监护室传统连续脑电图确认存在非惊厥性癫痫发作的患者,评估床旁护士在个体化简短培训后每小时判读定量脑电图(节律性频谱图与振幅整合脑电图,左右半球,1小时时段)检测复发性癫痫发作的准确性,以两名委员会认证神经电生理医师对传统连续脑电图的判读为金标准。共纳入20例患者、分析174个1小时定量脑电图时段,其中47个时段(27%)含癫痫发作。护士判读的敏感度为85.1%(95%CI 71.1-93.1%),特异度为89.8%(95%CI 82.8-94.2%),假阳性率0.1次/小时。半球性癫痫发作(>4个单侧脑电图电极)比局灶性发作(≤4个单侧电极)更容易被护士在定量脑电图上正确识别(P=0.03)。作者认为定量脑电图是一种有前景的工具,可能由非神经电生理医师使用,并可能促成非惊厥性癫痫发作的更早发现。

要点

  • 经过针对具体患者的简短定量脑电图培训后,神经重症监护室护士床旁实时判读检测复发性非惊厥性癫痫发作的敏感度为85.1%(95%CI 71.1-93.1%),特异度为89.8%(95%CI 82.8-94.2%)。
  • 护士每小时判读定量脑电图的假阳性率为0.1次/小时,174个1小时时段中47个(27%)含癫痫发作。
  • 半球性癫痫发作(>4个单侧脑电图电极)比局灶性发作(≤4个单侧电极)更容易被护士在定量脑电图上正确识别(P=0.03)。
  • 床旁定量脑电图显示由左右半球节律性频谱图和左右半球振幅整合脑电图组成,以1小时为时段。
  • 作者认为定量脑电图是一种有前景的工具,可能由非神经电生理医师使用,并可能促成非惊厥性癫痫发作的更早发现。

适用人群与场景

  • 2016至2018年入住杜克神经重症监护室、经传统连续脑电图判读确认存在非惊厥性癫痫发作的患者。

研究设计与关键结果

  • 前瞻性单机构研究,纳入20例患者,分析174个1小时定量脑电图时段,其中47个时段(27%)含癫痫发作。
  • 护士每小时判读定量脑电图检测癫痫发作的敏感度为85.1%(95%CI 71.1-93.1%),特异度为89.8%(95%CI 82.8-94.2%),对照金标准为两名委员会认证神经电生理医师对传统连续脑电图的判读。
  • 假阳性率为0.1次/小时。
  • 半球性癫痫发作(>4个单侧脑电图电极)比局灶性发作(≤4个单侧电极)更容易被护士在定量脑电图上正确识别(P=0.03)。

证据类型、等级与局限

  • 证据类型:前瞻性单机构研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,经过针对具体患者的简短定量脑电图培训后,神经重症监护室护士床旁实时判读定量脑电图对复发性非惊厥性癫痫发作检测表现出良好的敏感度且假阳性率低。
  • 作者认为,定量脑电图是一种有前景的工具,可能由非神经电生理医师使用,并可能促成非惊厥性癫痫发作的更早发现。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Non-convulsive seizures (NCS) are a common occurrence in the neurologic intensive care unit (Neuro-ICU) and are associated with worse outcomes. Continuous electroencephalogram (cEEG) monitoring is necessary for the detection of NCS; however, delays in interpretation are a barrier to early treatment. Quantitative EEG (qEEG) calculates a time-compressed simplified visual display from raw EEG data. This study aims to evaluate the performance of Neuro-ICU nurses utilizing bedside, real-time qEEG interpretation for detecting recurrent NCS.

METHODS: This is a prospective, single-institution study of patients admitted to the Duke Neuro-ICU between 2016 and 2018 who had NCS identified on traditional cEEG review. The accuracy of recurrent seizure detection on hourly qEEG review by bedside Neuro-ICU nurses was compared to the gold standard of cEEG interpretation by two board-certified neurophysiologists. The nurses first received brief qEEG training, individualized for their specific patient. The bedside qEEG display consisted of rhythmicity spectrogram (left and right hemispheres) and amplitude-integrated EEG (left and right hemispheres) in 1-h epochs.

RESULTS: Twenty patients were included and 174 1-h qEEG blocks were analyzed. Forty-seven blocks contained seizures (27%). The sensitivity was 85.1% (95% CI 71.1-93.1%), and the specificity was 89.8% (82.8-94.2%) for the detection of seizures for each 1-h block when compared to interpretation of conventional cEEG by two neurophysiologists. The false positive rate was 0.1/h. Hemispheric seizures (> 4 unilateral EEG electrodes) were more likely to be correctly identified by nurses on qEEG than focal seizures (≤ 4 unilateral electrodes) (p = 0.03).

CONCLUSIONS: After tailored training sessions, Neuro-ICU nurses demonstrated a good sensitivity for the interpretation of bedside real-time qEEG for the detection of recurrent NCS with a low false positive rate. qEEG is a promising tool that may be used by non-neurophysiologists and may lead to earlier detection of NCS.

来源:Neurocrit Care,查看原文。版权归原作者所有。

参考来源

  1. Kang JH, Sherill GC, Sinha SR, et al. A Trial of Real-Time Electrographic Seizure Detection by Neuro-ICU Nurses Using a Panel of Quantitative EEG Trends. Neurocrit Care. 2019. PMID: 30788707. doi:10.1007/s12028-019-00673-z

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。