文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

超声入射角度对收缩期峰值流速变异的影响

Effect of insonation angle on peak systolic velocity variation.
PubMed 文献 · Am J Emerg Med · 2019-01-29
一句话结论在急诊科51例受试者中,PSV变异高度依赖超声入射角度,46°、60°、90°之间一致性仅为轻微至中等,被动抬腿试验在90°时平均ΔPSV达18%。

该研究在急诊科纳入51例受试者,采用多普勒测量不同入射角度(46°、60°、90°)下的收缩期峰值流速(PSV),分别以被动抬腿试验(PLR)和呼吸变异(RV)作为试验方法计算ΔPSV。结果显示,PLR试验对应的平均ΔPSV在46°和60°组为9%,在90°组为18%,标准误分别为6%、7%和14%。以46°为相对金标准,RV法在60°和90°的Kappa分别为0.23和0.11,PLR法分别为0.23和0.01。结论指出PSV变异高度依赖入射角度,不同角度间ΔPSV一致性仅为轻微至中等,应进一步研究评估ΔPSV的最佳入射角度。

要点

  • 在急诊科51例受试者中,PLR试验对应的平均ΔPSV在46°和60°组为9%,在90°组为18%,标准误分别为6%、7%、14%。
  • 以46°为相对金标准,RV法在60°的Kappa为0.23,在90°为0.11;PLR法在60°为0.23,在90°为0.01。
  • 不同入射角度间ΔPSV一致性仅为轻微至中等,PSV变异高度依赖入射角度。
  • 作者认为应进一步研究评估ΔPSV的最佳入射角度。

适用人群与场景

  • 就诊于急诊科的51例受试者。

诊断标准与关键阈值

  • ΔPSV结果分为两组:ΔPSV > 10%组和ΔPSV ≤ 10%组。

研究设计与关键结果

  • 研究类型为在急诊科51例受试者中进行的多普勒超声测量研究,采用入射角度46°、60°、90°测量最小和最大PSV,分别以PLR和RV作为试验方法计算ΔPSV。
  • PLR试验对应的平均ΔPSV在46°和60°组为9%,在90°组为18%,标准误分别为6%、7%、14%。
  • 以46°为相对金标准,RV法在60°的Kappa为0.23,在90°为0.11;PLR法在60°为0.23,在90°为0.01。

证据类型、等级与局限

  • 证据类型为在急诊科51例受试者中进行的超声测量研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,PSV变异高度依赖入射角度,不同入射角度间ΔPSV一致性仅为轻微至中等。
  • 作者认为,应进一步研究评估ΔPSV的最佳入射角度。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: As point of care ultrasound (POCUS) has become more integrated into emergency and critical care medicine, there has been increased interest in utilizing ultrasound to assess volume status. However, recent studies of carotid POCUS on volume status and fluid responsiveness fail to recognize the effect insonation angle has on their results. To address this, we studied the effect of insonation angle on peak systolic velocity (PSV) change associated with respiratory variation (RV) and passive leg raise (PLR).

METHODS: Doppler measurements were obtained from 51 subjects presenting to the ED. Minimal and maximal PSV were obtained using insonation angles of 46°, 60°, and 90°. ∆PSV was calculated using PLR and RV as trial methods. Results were categorized into two groups, those with a ∆PSV > 10% and those with a ∆PSV ≤ 10%. ∆PSV mean and standard error, as well as measures of agreement were calculated.

RESULTS: Mean ∆PSV associated with PLR test was 9% in the 46° and 60° groups, and 18% in the 90° group, with standard errors of 6, 7, and 14%, respectively. Using 46° as our relative gold standard, Kappa was 0.23 at 60° and 0.11 at 90° with RV as the trial method, and 0.23 at 60° and 0.01 at 90° with a PLR as the trial method.

CONCLUSIONS: Variation in PSV is heavily dependent on insonation angle. There was only slight to fair agreement in ∆PSV among the various insonation angles. Further investigation of the optimal insonation angle to assess ∆PSV should be undertaken.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Radparvar JR, Lim G, Chiem AT, et al. Effect of insonation angle on peak systolic velocity variation. Am J Emerg Med. 2019. PMID: 30718117. doi:10.1016/j.ajem.2019.01.050

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。