文献速递重症综合管理与镇静镇痛呼吸衰竭与机械通气

重症监护病房机械通气患者早期目标导向康复运动的安全标准:一项系统评价

[Safety criteria for early goal-oriented rehabilition exercise in patients undergoing mechanical ventilation in intensive care unit: a systematic review].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2019-01-01
一句话结论系统评价纳入24篇文献4647例患者,提出ICU机械通气患者早期目标导向康复运动的安全标准涵盖心血管、呼吸、神经、骨科及其他5个系统共20个变量或参数。

该系统评价检索CBM、CNKI、万方、PubMed、Cochrane Library和Web of Science等数据库至2018年3月,纳入24篇关于ICU机械通气患者早期活动的文献,共4647例患者,其中11项RCT涉及1031例(对照组509例、观察组522例),13项队列研究涉及3616例。早期活动包括床上主动和被动活动、坐起、床椅转移、站立和行走。系统评价显示安全标准涉及5个系统20个变量或参数,中心血管和呼吸系统被引用最多。结论认为各系统安全标准或变量在不同文献间一致性较高,但参数需进一步高质量研究验证。

要点

  • 心血管系统安全标准包括40次/min<心率<130次/min(n=4)、血流动力学稳定(n=5)、无心肌梗死(n=3)、无心律失常(n=4)、无血管活性药物(n=4)、90 mmHg<收缩压<200 mmHg(n=4)、65 mmHg≤平均动脉压≤110 mmHg(n=3)、无心肺复苏史(n=5)。
  • 呼吸系统安全标准包括5次/min<呼吸频率<40次/min(n=5)、吸入氧浓度≤0.60且呼气末正压≤10 cmH2O(n=4)、吸入氧浓度<0.60或呼气末正压<10 cmH2O(n=3)、脉搏血氧饱和度>0.88(n=5)。
  • 神经系统安全标准包括无神经肌肉疾病(n=7)、无颅内压增高(n=7)、无昏迷(n=4)、能理解并正确执行指令(n=4)。
  • 骨科系统安全标准包括无骨折(n=3)、无不稳定性骨折(n=8);其他因素包括无开放性腹部伤口(n=4)、非姑息治疗(n=3)。
  • 不同文献报告的各系统安全标准或变量一致性较高,但参数需进一步高质量研究验证。

适用人群与场景

  • 重症监护病房(ICU)接受机械通气的患者,来自11项RCT(1031例,对照组509例、观察组522例)和13项队列研究(3616例)。
  • 早期活动包括床上主动和被动活动、坐起、床椅转移、站立和行走。

诊断标准与关键阈值

  • 心血管系统:40次/min<心率<130次/min(n=4);血流动力学稳定(n=5);无心肌梗死(n=3);无心律失常(n=4);无血管活性药物(n=4);90 mmHg<收缩压<200 mmHg(n=4);65 mmHg≤平均动脉压≤110 mmHg(n=3);无心肺复苏史(n=5)。
  • 呼吸系统:5次/min<呼吸频率<40次/min(n=5);吸入氧浓度≤0.60且呼气末正压≤10 cmH2O(n=4);吸入氧浓度<0.60或呼气末正压<10 cmH2O(n=3);脉搏血氧饱和度>0.88(n=5)。
  • 神经系统:无神经肌肉疾病(n=7);无颅内压增高(n=7);无昏迷(n=4);能理解并正确执行指令(n=4)。
  • 骨科系统:无骨折(n=3);无不稳定性骨折(n=8)。
  • 其他因素:无开放性腹部伤口(n=4);非姑息治疗(n=3)。

研究设计与关键结果

  • 系统评价纳入24篇关于ICU机械通气患者早期活动的文献,共4647例患者,其中11项RCT涉及1031例(对照组509例、观察组522例),13项队列研究涉及3616例。
  • RCT对照组接受ICU常规护理,观察组接受早期活动;队列研究为无对照组的早期活动。
  • 安全标准涉及5个系统20个变量或参数:心血管系统8个、呼吸系统4个、神经系统4个、骨科系统2个、其他因素2个。
  • 心血管和呼吸系统是被引用最多的变量或参数所在的系统。

证据类型、等级与局限

  • 证据类型:系统评价,纳入RCT和队列研究;RCT采用Cochrane 5.1.0评估质量,队列研究采用Newcastle-Ottawa量表(NOS)评估质量。
  • 局限:参数需进一步高质量研究验证。

对床旁实践的改变

  • 该系统评价汇总的安全标准可用于ICU机械通气患者早期目标导向康复运动前的心血管、呼吸、神经、骨科及其他系统评估,中心血管和呼吸系统变量或参数被引用最多。
  • 作者认为各系统安全标准或变量在不同文献间一致性较高,但参数需进一步高质量研究验证。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To determine the safety criteria for early goal-oriented rehabilition exercise in patients undergoing mechanical ventilation in intensive care unit (ICU) by systematic review.

METHODS: Randomized controlled trails (RCTs) and cohort studies about early goal-oriented rehabilition exercise in patients undergoing mechanical ventilation in ICU were retrieved in CBM, CNKI, Wanfang Data, PubMed, Cochrane Library and Web of Science from their foundation to March 2018, and other sources as supplement was also retrieved. The intervention program of RCT study was ICU routine nursing in control group, early activity in observation group, and early activity in cohort study without control group. Early activities included active and passive activities on the bed, sitting upright, bed-chair transfer, standing and walking. Literature screening and data extraction were performed independently by two researchers. Variables or parameters related to cardiovascular, respiratory, nervous, orthopedic and other systems were collected for safety criteria. Variables or parameters used in at least three literatures were collected for each system. Cochrane 5.1.0 was used to evaluate the quality of RCT study, and Newcastle-Ottawa scale (NOS) was used to evaluate the quality of cohort study.

RESULTS: A total of 24 articles about early activity of patients undergoing mechanical ventilation in ICU were enrolled, involving 4 647 patients, including 11 RCT studies involving 1 031 patients, 509 in control group and 522 in observation group; 13 cohort studies including 3 616 patients. It was shown by systematic review that safety criteria for early activity in patients undergoing mechanical ventilation in ICU involved five systems, 20 variables or parameters. The cardiovascular system included 8 variables or parameters, such as 40 bpm < heart rate (HR) < 130 bpm (n = 4), hemodynamic stability (n = 5), no myocardial infarction (n = 3), no arrhythmia (n = 4), no vascular active drugs (n = 4), 90 mmHg < systolic blood pressure (SBP) < 200 mmHg (1 mmHg = 0.133 kPa, n = 4), 65 mmHg ≤ mean arterial pressure (MAP) ≤ 110 mmHg (n = 3), no history of cardiopulmonary resuscitation (CPR, n = 5). The respiratory system included 4 variables or parameters, involving 5 times/min < respiratory rate (RR) < 40 times/min (n = 5), fraction of inspired oxygen (FiO2) ≤ 0.60 and positive end-expiratory pressure (PEEP) ≤ 10 cmH2O (1 cmH2O = 0.098 kPa, n = 4), FiO2 < 0.60 or PEEP < 10 cmH2O (n = 3), pulse blood oxygenation (SpO2) > 0.88 (n = 5). The nervous system included 4 variables, including no neuromuscular disease (n = 7), no increase in intracranial pressure (n = 7), no coma (n = 4), understand and do the right thing (n = 4). The orthopedic system included 2 variables, including no fracture (n = 3), no unstable fracture (n = 8). Other factors included 2 variables, including no open abdomen wound (n = 4), and no palliative care (n = 3).

CONCLUSIONS: This study identified safety criteria for early goal-directed rehabilition exercise in patients undergoing mechanical ventilation in ICU included five systems of cardiovascular, respiratory, neurological, orthopedic, and other systems, in which cardiovascular and respiratory systems were the most frequently cited variables or parameters. The consistency of each system security criteria or variables reported by different literatures was high, but the parameters need to be further verified by high-quality study.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Ding N, Yao L, Zhang Z, et al. [Safety criteria for early goal-oriented rehabilition exercise in patients undergoing mechanical ventilation in intensive care unit: a systematic review]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2019. PMID: 30707876. doi:10.3760/cma.j.issn.2095-4352.2019.01.018

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。