气管插管是否增加院外心脏骤停的胸外按压比例:CAAM试验亚组研究
本研究为CAAM试验的单中心亚组分析,纳入本中心招募的112例成人院外心脏骤停患者,比较气管插管与球囊面罩通气对胸外按压比例的影响。未调整的胸外按压比例插管组为0.89、球囊面罩组为0.88(p=0.19)。校正Utstein混杂因素后,两组整体干预期间胸外按压比例无差异(ΔCCF [ETI-BMV] 0.301,95%CI -1.9至2.51,p=0.79)。插管组通气相关无血流时间更短(32 vs 127秒,p<0.001),但心律检查相关无血流时间(69.5 vs 42.5秒,p=0.02)和机械胸外按压装置放置相关无血流时间(29 vs 20秒,p=0.04)更长;第一周期胸外按压比例插管组低于球囊面罩组(0.74 vs 0.81,p=0.02)。
要点
- 校正混杂因素后,气管插管与球囊面罩通气的整体干预期间胸外按压比例无差异(ΔCCF 0.301,95%CI -1.9至2.51,p=0.79)。
- 插管组通气相关无血流时间短于球囊面罩组(32 vs 127秒,p<0.001)。
- 插管组心律检查相关无血流时间长于球囊面罩组(69.5 vs 42.5秒,p=0.02)。
- 插管组机械胸外按压装置放置相关无血流时间长于球囊面罩组(29 vs 20秒,p=0.04)。
- 第一周期胸外按压比例插管组低于球囊面罩组(0.74 vs 0.81,p=0.02)。
适用人群与场景
- 本中心在CAAM试验中招募的成人院外心脏骤停患者,共分析112例。
研究设计与关键结果
- 研究类型为CAAM试验的单中心亚组研究,分析本中心招募的112例成人院外心脏骤停患者,比较气管插管与球囊面罩通气。
- 未调整胸外按压比例:气管插管组0.89 vs 球囊面罩组0.88(p=0.19)。
- 校正Utstein混杂因素后整体干预期间胸外按压比例无差异:ΔCCF(ETI-BMV)0.301,95%CI -1.9至2.51,p=0.79。
- 通气相关无血流时间:气管插管组32秒 vs 球囊面罩组127秒(p<0.001)。
- 心律检查相关无血流时间:气管插管组69.5秒 vs 球囊面罩组42.5秒(p=0.02)。
- 机械胸外按压装置放置相关无血流时间:气管插管组29秒 vs 球囊面罩组20秒(p=0.04)。
- 第一周期胸外按压比例:气管插管组0.74 vs 球囊面罩组0.81(p=0.02)。
证据类型、等级与局限
- 证据类型:CAAM试验的亚组研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论认为,在本亚组中,与球囊面罩通气相比,气管插管未改变院外心脏骤停整体干预期间的胸外按压比例。
- 作者观察到气管插管组通气相关无血流时间更短,而机械胸外按压装置放置相关无血流时间更长。
- 作者观察到气管插管组第一周期胸外按压比例更低。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Optimal out of hospital cardiac arrest (OHCA) airway management strategies remain unclear. We compared chest compression fraction (CCF) between patients receiving endotracheal intubation (ETI) versus bag mask ventilation (BMV).
METHODS: We studied adult OHCA enrolled from our center in the CAAM trial. Primary exposures were ETI or BMV. Primary outcome was whole intervention CCF, adjusted for Utstein confounders. Secondary outcomes were per cycle CCF, no flow time associated (NFT) with ventilation, rhythms checks and mechanical chest compression device placement.
RESULTS: Of 2040 OHCA enrolled in the CAAM trial we analyzed 112 cases recruited by our center. Unadjusted CCF was 0.89 for ETI and 0.88 for BMV (p = 0.19). Compared with BMV, ETI achieved lower NFT associated with ventilations (32 vs 127 s; p < 0.001). ETI cases experienced higher NFT associated with rhythm checks (69.5 vs 42.5 s p = 0.02) and with mechanical chest compression placement (29 vs 20 s; p = 0.04). CCF was higher during the first cycle in BMV than in ETI patients (0.81 vs 0.74; p = 0.02). After correction for confounders we observed no difference in global intervention CCF between the ETI and BMV (ΔCCF [ETI-BMV] 0.301; [95%CI: -1.9 to 2.51]; p = 0.79).
CONCLUSION: In our substudy whole intervention CCF among OHCA was not modified by ETI compared to BMV. In the ETI group we observed lower NFT associated with ventilations and higher NFT associated with mechanical chest compression devices placement. CCF was lower in the ETI group during the first cycle.
参考来源
- Malinverni S, Bartiaux M, Cavallotto F, et al. Does endotracheal intubation increases chest compression fraction in out of hospital cardiac arrest: A substudy of the CAAM trial. Resuscitation. 2019. PMID: 30753851. doi:10.1016/j.resuscitation.2019.01.032
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。