文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

脓毒性休克早期即出现急性纤溶关闭并与发病率和死亡率增加相关:一项观察性先导研究结果

Acute fibrinolysis shutdown occurs early in septic shock and is associated with increased morbidity and mortality: results of an observational pilot study.
PubMed 文献 · Ann Intensive Care · 2019-01-30
一句话结论脓毒性休克患者早期即出现急性纤溶关闭,血栓弹力测定纤溶指数升高,与病情严重程度和死亡相关。

该观察性先导研究纳入90例受试者(30例脓毒性休克、30例手术对照、30例健康志愿者),在脓毒症起病时或手术前后及3小时、6小时、12小时、24小时、48小时和7天后采集血样,行黏弹性与血小板聚集床旁检测、酶联免疫吸附与凝血酶生成试验及液相色谱-质谱检测。结果显示脓毒性休克患者起病时纤溶酶原激活物抑制剂-1已显著升高,血栓弹力测定纤溶指数显著升高,该效应持续整个7天观察期,在重症及未存活脓毒症患者中最明显;组织型纤溶酶原激活物显著升高但未影响血栓弹力测定纤溶指数。纤溶指数可用于脓毒性休克的早期诊断(如45分钟纤溶指数曲线下面积高达0.933)和预后判断(如60分钟纤溶指数曲线下面积高达1.000)。结论认为早期抑制纤溶酶原激活导致急性纤溶关闭、血凝块稳定性改善,并与脓毒症患者发病率和死亡率增加相关。

要点

  • 脓毒性休克患者起病时纤溶酶原激活物抑制剂-1已显著升高,血栓弹力测定纤溶指数显著高于手术对照和健康志愿者两组。
  • 组织型纤溶酶原激活物显著升高但未影响血栓弹力测定纤溶指数。
  • 纤溶指数升高持续整个7天观察期,在重症及未存活脓毒症患者中最明显。
  • 血栓弹力测定纤溶指数可用于脓毒性休克早期诊断(45分钟纤溶指数曲线下面积高达0.933)和预后判断(60分钟纤溶指数曲线下面积高达1.000)。
  • 早期抑制纤溶酶原激活导致急性纤溶关闭、血凝块稳定性改善,并与脓毒症患者发病率和死亡率增加相关。

适用人群与场景

  • 共90例受试者:30例脓毒性休克患者、30例手术对照患者、30例健康志愿者。
  • 脓毒性休克患者在脓毒症起病时及起病后3小时、6小时、12小时、24小时、48小时和7天采集血样;手术对照在手术前、手术后即刻及相同时间点采集;健康志愿者仅采集一次。

研究设计与关键结果

  • 研究类型为观察性先导研究,共纳入90例受试者(30例脓毒性休克、30例手术对照、30例健康志愿者)。
  • 黏弹性床旁检测显示脓毒性休克患者早期即出现纤溶关闭;组织型纤溶酶原激活物显著升高但未影响血栓弹力测定纤溶指数。
  • 纤溶酶原激活物抑制剂-1在脓毒症起病时已显著升高,脓毒性休克患者血栓弹力测定纤溶指数显著高于手术对照和健康志愿者两组,该效应持续整个7天观察期。
  • 纤溶指数升高在重症及未存活脓毒症患者中最明显。
  • 血栓弹力测定纤溶指数用于脓毒性休克早期诊断的曲线下面积:45分钟纤溶指数高达0.933;用于预后判断的曲线下面积:60分钟纤溶指数高达1.000。

证据类型、等级与局限

  • 证据类型:观察性先导研究。
  • 研究经当地伦理委员会批准(海德堡医学院伦理委员会;试验代码S247-2014/德国临床试验注册中心(DRKS)-ID:DRKS00008090;追溯注册日期:2015年5月7日)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Septic coagulopathy represents a very dynamic disease entity, tilting from initial hypercoagulability towards a subsequent hypocoagulable disease state, entitled overt disseminated intravascular coagulation. Acute fibrinolysis shutdown has recently been described to be a crucial component of initial hypercoagulability in critically ill patients, although the underlying pathomechanisms, the specific temporal kinetics and its outcome relevance in patients with sepsis remain to be determined.

METHODS: In total, 90 patients (30 with septic shock, 30 surgical controls and 30 healthy volunteers) were enrolled. Blood samples were collected at sepsis onset or prior and immediately after the surgical procedure as well as 3 h, 6 h, 12 h, 24 h, 48 h and 7 d later, whereas blood samples from healthy volunteers were collected once. Besides viscoelastic and aggregometric point-of-care testing (POCT), enzyme-linked immunosorbent and thrombin generation assays and liquid chromatography-mass spectrometry-based measurements were performed.

RESULTS: As assessed by viscoelastic POCT, fibrinolysis shutdown occurred early in sepsis. Significant increases in tissue plasminogen activator had no effect on thromboelastometrical lysis indices (LIs). Contrariwise, plasminogen activator inhibitor-1 was already significantly increased at sepsis onset, which was paralleled by significantly increased LIs in patients suffering from septic shock in comparison with both control groups. This effect persisted throughout the 7-day observation period and was most pronounced in severely ill as well as non-surviving septic patients. Thromboelastometrical LI, therefore, proved to be suitable for early diagnosis [e.g. LI 45 min: area under the curve (AUC) up to 0.933] as well as prognosis (e.g. LI 60 min: AUC up to 1.000) of septic shock.

CONCLUSIONS: Early inhibition of plasminogen activation leads to acute fibrinolysis shutdown with improved clot stability and is associated with increased morbidity and mortality in septic patients. Trial registration This study was approved by the local ethics committee (Ethics Committee of the Medical Faculty of Heidelberg; Trial-Code No. S247-2014/German Clinical Trials Register (DRKS)-ID: DRKS00008090; retrospectively registered: 07.05.2015). All study patients or their legal representatives signed written informed consent.

来源:Ann Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Schmitt FCF, Manolov V, Morgenstern J, et al. Acute fibrinolysis shutdown occurs early in septic shock and is associated with increased morbidity and mortality: results of an observational pilot study. Ann Intensive Care. 2019. PMID: 30701381. doi:10.1186/s13613-019-0499-6

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。