旁观者使用自动体外除颤器在不可电击院外心脏骤停中的应用
该研究为回顾性分析,纳入2005—2015年9个Resuscitation Outcomes Consortium站点中成人非创伤性、公共场所、旁观者目击的不可电击院外心脏骤停患者2809例,其中8.4%接受了旁观者自动体外除颤器应用。应用自动体外除颤器组旁观者心肺复苏率更高(99% vs 51%,p<0.001)。应用与未应用自动体外除颤器组院前自主循环恢复率分别为44.1% vs 39.8%,到达急诊时有脉搏率均为29.6%,出院存活率分别为9.7% vs 11.1%。校正Utstein变量后,应用自动体外除颤器与出院存活的OR为0.90(95%CI 0.57-1.42);进一步校正心肺复苏频率后OR为0.92(95%CI 0.57-1.47)。结论认为应用自动体外除颤器与更高的旁观者心肺复苏率相关,但未改变院前自主循环恢复、到达急诊时有脉搏及出院存活概率。
要点
- 在不可电击的公共场所目击院外心脏骤停中,仅8.4%的患者接受了旁观者自动体外除颤器应用。
- 应用自动体外除颤器组旁观者心肺复苏率为99%,未应用组为51%(p<0.001)。
- 应用与未应用自动体外除颤器组院前自主循环恢复率分别为44.1% vs 39.8%,到达急诊时有脉搏率均为29.6%,出院存活率分别为9.7% vs 11.1%。
- 校正Utstein变量后,应用自动体外除颤器与出院存活的OR为0.90(95%CI 0.57-1.42);进一步校正心肺复苏频率后OR为0.92(95%CI 0.57-1.47)。
- 作者结论认为,在不可电击的公共场所目击院外心脏骤停中应用自动体外除颤器与更高的旁观者心肺复苏率相关,但未改变院前自主循环恢复、到达急诊时有脉搏及出院存活概率。
适用人群与场景
- 成人非创伤性、公共场所、旁观者目击的不可电击院外心脏骤停患者,数据来自2005—2015年参与Resuscitation Outcomes Consortium的9个站点。
- 不可电击心脏骤停定义为旁观者应用的自动体外除颤器未给予电击,且经急救医疗服务到达时初始心律确认。
诊断标准与关键阈值
- 不可电击心脏骤停:旁观者应用的自动体外除颤器未给予电击,且经急救医疗服务到达时初始心律确认。
研究设计与关键结果
- 研究类型:回顾性分析;样本量:2809例不可电击的公共场所目击院外心脏骤停患者;数据来自2005—2015年参与Resuscitation Outcomes Consortium的9个站点。
- 8.4%的患者接受了旁观者自动体外除颤器应用。
- 应用自动体外除颤器组旁观者心肺复苏率为99%,未应用组为51%(p<0.001)。
- 应用与未应用自动体外除颤器组院前自主循环恢复率分别为44.1% vs 39.8%,到达急诊时有脉搏率均为29.6%,出院存活率分别为9.7% vs 11.1%。
- 校正Utstein变量(除外旁观者心肺复苏)后,应用自动体外除颤器与出院存活的OR为0.90(95%CI 0.57-1.42);进一步校正应用组更高的心肺复苏频率后OR为0.92(95%CI 0.57-1.47)。
证据类型、等级与局限
- 证据类型:回顾性分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在不可电击的公共场所目击院外心脏骤停中,应用自动体外除颤器与更高的旁观者心肺复苏率相关(99% vs 51%),但院前自主循环恢复、到达急诊时有脉搏及出院存活概率未因应用自动体外除颤器而改变。
- 作者结论认为,应用自动体外除颤器与更高的旁观者心肺复苏率相关,但未改变院前自主循环恢复、到达急诊时有脉搏及出院存活概率。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: An increasing proportion of patients with OHCA present with non-shockable rhythms, among whom the benefit from AED application is not known.
METHODS: We performed a retrospective analysis of adults with non-traumatic, public, bystander-witnessed, non-shockable OHCA occurring between 2005-2015 at 9 locations participating in the Resuscitation Outcomes Consortium. Non-shockable arrest was defined as when no shock was administered by a bystander applied AED and confirmed by the initial rhythm on EMS arrival. Outcomes were compared between patients with non-shockable OHCA in whom a bystander AED was or was not applied.
RESULTS: Among 2809 patients with non-shockable public, witnessed OHCA, 8.4% had an AED applied. CPR was more often performed in the AED-applied group (99% vs. 51% of patients, p < 0.001). Among patients in whom an AED was not applied, 39.8% had any pre-hospital ROSC, 29.6% had a pulse at ED arrival and 11.1% survived to hospital discharge compared to 44.1%, 29.6% and 9.7%, respectively with AED application. After adjustment for the Utstein variables excluding bystander CPR, the OR for survival to hospital discharge for AED application was 0.90 (95% CI:0.57-1.42); when adjusted for the higher frequency of CPR in the AED group the OR was 0.92 (95% CI:0.57-1.47).
CONCLUSIONS: The application of an AED in non-shockable public witnessed OHCA was associated with a higher frequency of bystander CPR. The probabilities of pre-hospital ROSC, pulse at ED arrival, and survival to hospital discharge were not altered by the application of an AED.
参考来源
- Pollack RA, Brown SP, May S, et al. Bystander automated external defibrillator application in non-shockable out-of-hospital cardiac arrest. Resuscitation. 2019. PMID: 30790694. doi:10.1016/j.resuscitation.2019.02.007
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。