左心室-动脉耦联与脓毒性休克患者的容量反应性
本研究为回顾性观察性研究,纳入35例脓毒性休克患者,经PiCCO监测液体复苏后按心指数增加是否超过10%分为容量反应组(VVr)和无反应组(VVur),评估有效动脉弹性(EaI)、左心室收缩末弹性(EesI)及EaI/EesI。结果显示VVr组ΔEaI、ΔEaI/EesI及ΔSVRI均显著低于VVur组(P<0.05);ΔEaI/EesI≤0组ΔCI、ΔSVI及ΔEesI显著高于ΔEaI/EesI>0组,且ΔEaI和ΔSVRI显著降低(P<0.05)。ΔCI与ΔEaI(r=-0.46,P=0.006)、ΔEaI/EesI(r=-0.65,P<0.001)及ΔSVRI(r=-0.59,P<0.001)呈负相关。ΔEaI/EesI≤0组容量反应者比例显著高于ΔEaI/EesI>0组(88.89% vs. 26.92%,P=0.01)。
要点
- 脓毒性休克患者中,容量反应组(VVr)的ΔEaI、ΔEaI/EesI及ΔSVRI显著低于容量无反应组(VVur)(P<0.05)。
- ΔEaI/EesI≤0组容量反应者比例为88.89%,显著高于ΔEaI/EesI>0组的26.92%(P=0.01)。
- ΔCI与ΔEaI(r=-0.46,P=0.006)、ΔEaI/EesI(r=-0.65,P<0.001)及ΔSVRI(r=-0.59,P<0.001)呈负相关。
- ΔEaI/EesI≤0组ΔCI、ΔSVI及ΔEesI显著高于ΔEaI/EesI>0组,而ΔEaI和ΔSVRI显著降低(P<0.05)。
适用人群与场景
- 脓毒性休克患者(n=35),经PiCCO监测液体复苏后,以全心舒张末期容积指数(GEDVI)增加超过10%定义为液体复苏成功。
诊断标准与关键阈值
- 容量反应性定义:PiCCO监测液体复苏后心指数增加超过10%为容量反应(VVr),否则为容量无反应(VVur)。
- VAC评估指标:有效动脉弹性(EaI)、左心室收缩末弹性(EesI)及EaI/EesI。
- VAC变化定义:EaI/EesI变化(ΔEaI/EesI)。
研究设计与关键结果
- 研究类型:回顾性观察性研究;样本量:35例脓毒性休克患者。
- 容量反应组(VVr)与无反应组(VVur)比较:ΔEaI、ΔEaI/EesI及ΔSVRI在VVr组显著低于VVur组(P<0.05)。
- ΔEaI/EesI≤0组与>0组比较:ΔCI、ΔSVI及ΔEesI在≤0组显著高于>0组;ΔEaI和ΔSVRI在≤0组显著低于>0组(P<0.05)。
- 相关性:ΔCI与ΔEaI(r=-0.46,P=0.006)、ΔEaI/EesI(r=-0.65,P<0.001)及ΔSVRI(r=-0.59,P<0.001)呈负相关。
- 容量反应者比例:ΔEaI/EesI≤0组为88.89%,ΔEaI/EesI>0组为26.92%(P=0.01)。
证据类型、等级与局限
- 证据类型:回顾性观察性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在脓毒性休克患者中,ΔEaI/EesI≤0与更高的容量反应性比例相关(88.89% vs. 26.92%),可能有助于床旁识别容量反应者。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Suboptimal ventricular arterial coupling (VAC) is one of the pivotal determinants of inefficient heart performance despite appropriate administration of fluids or vasopressors in shocks. Here, we investigate the performance of VAC in patients who are unresponsive to fluid administration in septic shock.
METHODS: This is a retrospective observational study of septic shock patients (n = 35). VAC was evaluated by effective arterial elastance (EaI), left ventricular end-systolic elastance (EesI), and EaI/EesI. Septic shock patients successfully fluid resuscitated after pulse indicator continuous cardiac output (PiCCO) monitoring, defined as an increase in general end-diastolic ventricular volume (GEDVI) more than 10%, were divided into volume responsive (VVr), and volume unresponsive (VVur) groups based on a cardiac index increase above 10%. We hypothesize that two groups of patients will exhibit dissimilarities of VAC variation, defined as EaI/EesI variation (ΔEaI/EesI).
RESULTS: Variations of EaI (ΔEaI), and EaI/EesI (ΔEaI/EesI), and systemic vascular resistance index (ΔSVRI) were significantly lower in the VVr group than those in the VVur group (P < 0.05). Variations of cardiac index (ΔCI), stroke volume index (ΔSVI), and EesI (ΔEesI) were significantly higher in patients with ΔEaI/EesI ≤ 0. Concomitantly, ΔEaI and ΔSVRI were significantly diminished as compared with patients with ΔEaI/EesI > 0 (P < 0.05). ΔCI has an inverse relationship with both ΔEaI (r = -0.46, P = 0.006), ΔEaI/EesI (r = -0.65, P < 0.001), and ΔSVRI (r = -0.59, P < 0.001). We observed more patients who were fluid responsive in the ΔEaI/EesI ≤ 0 group than in the group with ΔEaI/EesI > 0 (88.89% vs. 26.92%, P = 0.01).
CONCLUSIONS: Variation of VAC is often related to suboptimal ventricular volume responsiveness among patients with septic shock.
参考来源
- Li S, Wan X, Laudanski K, et al. Left-Sided Ventricular-arterial Coupling and Volume Responsiveness in Septic Shock Patients. Shock. 2019. PMID: 30807525. doi:10.1097/SHK.0000000000001327