文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

食管多普勒可通过呼气末与吸气末阻断试验预测液体反应性

Esophageal Doppler Can Predict Fluid Responsiveness Through End-Expiratory and End-Inspiratory Occlusion Tests.
PubMed 文献 · Crit Care Med · 2019-01-01
一句话结论在机械通气的急性循环衰竭患者中,食管多普勒估算的心指数在吸气末与呼气末阻断期间百分比变化的绝对值之和大于9%时,输注500 mL液体很可能增加心输出量。

这项前瞻性单中心研究纳入28例机械通气的急性循环衰竭成人患者,在输注500 mL生理盐水前后,用食管多普勒测量心指数,并分别在15秒吸气末阻断和呼气末阻断的最后5秒记录变化。以经肺热稀释法测得心指数增加≥15%定义液体反应者。结果显示,呼气末阻断期间食管多普勒心指数升高幅度在反应者中为8%±2%,非反应者为3%±1%(p<0.0001);吸气末阻断期间下降幅度在反应者中为-8%±5%,非反应者为-4%±2%(p=0.0002)。呼气末阻断诱导的心指数百分比变化预测液体反应性的ROC曲线下面积为1.00(95%CI 0.88-1.00),阈值为心指数增加4%;两次阻断期间心指数百分比变化绝对值之和的ROC曲线下面积为0.99(95%CI 0.86-1.00),阈值为9%。作者结论认为,若两次阻断试验诱导的食管多普勒心指数百分比变化绝对值之和大于9%,则输注500 mL液体很可能增加心输出量。

要点

  • 在机械通气的急性循环衰竭成人患者中,呼气末阻断期间食管多普勒心指数升高幅度在液体反应者中为8%±2%,非反应者为3%±1%(p<0.0001)。
  • 吸气末阻断期间食管多普勒心指数下降幅度在液体反应者中为-8%±5%,非反应者为-4%±2%(p=0.0002)。
  • 呼气末阻断诱导的心指数百分比变化预测液体反应性的ROC曲线下面积为1.00(95%CI 0.88-1.00),阈值为心指数增加4%。
  • 两次阻断期间心指数百分比变化绝对值之和预测液体反应性的ROC曲线下面积为0.99(95%CI 0.86-1.00),阈值为9%。
  • 作者结论认为,若两次阻断诱导的食管多普勒心指数百分比变化绝对值之和大于9%,则输注500 mL液体很可能增加心输出量。

适用人群与场景

  • 机械通气的成人急性循环衰竭患者,且临床医生决定给予液体治疗。

诊断标准与关键阈值

  • 液体反应者定义为:容量扩张后经肺热稀释法测得的心指数增加大于或等于15%。

处置流程与药物剂量

  • 在输注500 mL生理盐水前后,用食管多普勒测量心指数,并在连续15秒吸气末阻断和呼气末阻断的最后5秒记录心指数变化,两次阻断间隔1分钟。
  • 呼气末阻断诱导的食管多普勒心指数百分比变化阈值为增加4%,用于预测液体反应性。
  • 两次阻断诱导的食管多普勒心指数百分比变化绝对值之和阈值为9%,用于预测液体反应性。

研究设计与关键结果

  • 研究类型为前瞻性单中心研究,纳入28例机械通气的急性循环衰竭成人患者。
  • 呼气末阻断期间食管多普勒心指数升高幅度在液体反应者中为8%±2%,非反应者为3%±1%(p<0.0001)。
  • 吸气末阻断期间食管多普勒心指数下降幅度在液体反应者中为-8%±5%,非反应者为-4%±2%(p=0.0002)。
  • 呼气末阻断诱导的心指数百分比变化预测液体反应性的ROC曲线下面积为1.00(95%CI 0.88-1.00),阈值为心指数增加4%。
  • 两次阻断期间心指数百分比变化绝对值之和预测液体反应性的ROC曲线下面积为0.99(95%CI 0.86-1.00),阈值为9%。

证据类型、等级与局限

  • 证据类型:前瞻性单中心研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者结论认为,若两次阻断诱导的食管多普勒心指数百分比变化绝对值之和大于9%,则输注500 mL液体很可能增加心输出量。
  • 作者指出,该诊断阈值高于仅考虑呼气末阻断诱导的食管多普勒心指数百分比变化时的阈值。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: To assess whether, in patients under mechanical ventilation, fluid responsiveness is predicted by the effects of short respiratory holds on cardiac index estimated by esophageal Doppler.

DESIGN: Prospective, monocentric study.

SETTING: Medical ICU.

PATIENTS: Twenty-eight adult patients with acute circulatory failure and a decision of the clinicians in charge to administer fluids.

INTERVENTIONS: Before and after infusing 500 mL of saline, we measured cardiac index estimated by esophageal Doppler before and during the last 5 seconds of successive 15-second end-inspiratory occlusion and end-expiratory occlusion, separated by 1 minute. Patients in whom volume expansion increased cardiac index measured by transpulmonary thermodilution greater than or equal to 15% were defined as "fluid responders." Cardiac index measured by the Pulse Contour Cardiac Output device (from pulse contour analysis or transpulmonary thermodilution) was used as the reference.

MEASUREMENTS AND MAIN RESULTS: End-expiratory occlusion increased cardiac index estimated by esophageal Doppler more in responders than in nonresponders (8% ± 2% vs 3% ± 1%, respectively; p < 0.0001) and end-inspiratory occlusion decreased cardiac index estimated by esophageal Doppler more in responders than in nonresponders (-8% ± 5% vs -4% ± 2%, respectively; p = 0.0002). Fluid responsiveness was predicted by the end-expiratory occlusion induced percent change in cardiac index estimated by esophageal Doppler with an area under the receiver operating characteristic curve of 1.00 (95% CI, 0.88-1.00) and a threshold value of 4% increase in cardiac index estimated by esophageal Doppler. It was predicted by the sum of absolute values of percent changes in cardiac index estimated by esophageal Doppler during both occlusions with a similar area under the receiver operating characteristic curve (0.99 [0.86-1.00]) and with a threshold of 9% change in cardiac index estimated by esophageal Doppler, which is compatible with the esophageal Doppler precision.

CONCLUSIONS: If the absolute sum of the percent change in cardiac index estimated by esophageal Doppler induced by two successive end-inspiratory occlusion and end-expiratory occlusion maneuvers is greater than 9%, it is likely that a 500 mL fluid infusion will increase cardiac output. This diagnostic threshold is higher than if only end-expiratory occlusion induced percent changes in cardiac index estimated by esophageal Doppler are taken into account.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Dépret F, Jozwiak M, Teboul JL, et al. Esophageal Doppler Can Predict Fluid Responsiveness Through End-Expiratory and End-Inspiratory Occlusion Tests. Crit Care Med. 2019. PMID: 30379670. doi:10.1097/CCM.0000000000003522

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。